Surface Testing – Temperature Meter PCE-675
Easy-to-use infrared thermometer with red laser pointer / Measuring input for K-type / Surface temperatures / Air temperature / Humidity / Dew point temperature
The Surface Testing – Temperature Meter has a 13:1 spot-to-spot ratio and can accurately measure surface temperatures and ambient humidity over a very long distance. The temperature meter brings advantages, such as a simple operation and a red sighting laser. These features allow the near perfect alignment of the temperature meter for accurate measurements.
The temperature meter is universally applicable. The integrated flashlight allows the measuring point to be illuminated in the dark. The individual settings of the temperature meter allow a wide range of temperatures and humidity to be measured. The temperature meter does not have a fixed emission value, but has a setting span of 0.1 to 1.0, thus covering more than 90% of all temperature measurement tasks.
Highlights
- Low measurement sequence
- Emissivity adjustable between 0.1 and 1.0
- Automatic shutdown
- Switchable laser sighting aid
- Measured value display selectable between °C and °F
- Different exhibition settings
- Battery operation
- Compact and robust design
Technical specifications
- Measuring functionInfrared — Measuring range: -50 … 550 °C
- Measuring functionInfrared — Resolution: ≤ 1000 °C/°F: 0.1 °C/°F
- Measuring functionInfrared: > 1000 °C/°F: 1 °C/°F
- Measuring functionInfrared — Accuracy: -50 … 0 ºC: ± 3 ºC
- Measuring functionInfrared: > 0º C: ± 1.5 % or ± 2.0
- Measuring functionType K — Measuring range: -50 … 850 ºC
- Measuring functionType K — Resolution: ≤ 1000 °C/°F: 0.1 °C/°F
- Measuring functionType K: > 1000 °C/°F: 1 °C/°F
- Measuring functionType K — Accuracy: ± 1.5 % or ± 1.5 °C
- Measuring functionAir temperature — Measuring range: -20 … 60 ºC
- Measuring functionAir temperature — Resolution: 0.1 °C
- Measuring functionAir temperature — Accuracy: 0 … 40 ºC: ± 1.0 ºC
- Measuring functionAir temperature: Other: ± 2 °C
- Measuring functionHumidity — Measuring range: 0 … 100 % r.H.
- Measuring functionHumidity — Resolution: 1 %
- Measuring functionHumidity — Accuracy: 35 … 75 % r.H.:
- Measuring functionHumidity: ± 3.0 % r.H.
- Measuring functionHumidity: Other: ± 5 % r.H.
- Measuring functionDew point — Measuring range: -20 … 60 ºC
- Measuring functionDew point — Resolution: 0.1 °C
- Measuring functionDew point — Accuracy: 25 ºC, 40 … 80 % r.H.: ± 1.5 ºC
- Wet bulb temp. — Measuring range: -20 … 60ºC
- Wet bulb temp. — Resolution: 0.1 °C
- Wet bulb temp. — Accuracy: 25 °C: ± 1.5 °C
- Wet bulb temp.: Emissivity adjustable between 0.1 and 1.0
- Wet bulb temp.: Optical resolution 13 : 1
- Wet bulb temp. — Response time: ≤ 500 ms
- Wet bulb temp.: Spectral sensitivity 8 … 14 um
- Wet bulb temp.: Laser≤ 1 mW, 630 … 670 nm, class 2 laser
- Automatic shutdown after one minute — Operating conditions: 0 … 50 ºC / ≤ 95% r.H.
- Automatic shutdown after one minute — Storage conditions: -20 … 70 ºC / ≤ 80 % r.H.
- Automatic shutdown after one minute — Power supply: 9 V battery
- Automatic shutdown after one minute — Weight: ca. 130 g
Delivery scope
- 1 x Surface Testing – Temperature Meter PCE-675
- 1 x Thermocouple Type-K
- 1 x 9 V block battery
- 1 x Carrying bag
- 1 x User manual