Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PC200 Particle Counter with Calibration Certificate

PC200 Particle Counter with Calibration Certificate

Its numerous measurement functions and the PC200’s compliance with ISO 21501-4 provide users with flexible application options, ranging from cleanroom testing and filter efficiency testing to workplace exposure monitoring and quality assurance measures.

  • In stock
1 184 price including km
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment

PC200 Particle Counter with Calibration Certificate

particle counter

Its numerous measurement functions and the PC200’s compliance with ISO 21501-4 provide users with flexible application options, ranging from cleanroom testing and filter efficiency testing to workplace exposure monitoring and quality assurance measures.

The measured values for all six particle size channels are displayed simultaneously and are easy to read on the PC200’s 2.8-inch color LCD screen.

An additional color indicator display with an automatic audible alarm facilitates the rapid detection of critical particle concentrations.

In addition to the number and size of air particles, the PC200 also measures environmental parameters such as relative humidity, dew point, and wet-bulb temperature.

It also features a built-in digital camera for photographing and videotaping the measurement environment.

The PC200 data logger’s data storage function allows you to save 5,000 sets of measurement data to its internal memory, which can be expanded to 8 GB via a microSD card, thereby significantly increasing storage capacity. After measurement, all stored data can be quickly and easily transferred to a computer via the USB port for documentation or evaluation.

Benefits of exercise:

  • Particle Counter with a Long-Life Laser Diode
  • Complies with the ISO 21501-4 standard
  • 6 particle-size channels ranging from 0.3 to 10 μm
  • Determines the size fractions and concentration of airborne particles
  • It also measures environmental climate parameters such as relative humidity, air temperature, dew point, and wet bulb temperature
  • Data logger with 5,000 readings of internal memory (optional memory expansion via microSD card up to 8 GB)
  • Integrated digital camera for photo and video documentation in the measurement environment
  • An additional color indicator display with an automatic audible alarm for rapid detection of critical particle concentrations
  • 2.8-inch backlit color LCD screen for simultaneous display of all measured parameters
  • Ergonomic one-handed control
  • Tripod thread for long-term measurements on a tripod
  • Exporting Computer Measurement Data via a USB Connection
  • Delivery with a calibration certificate

PC200 Technical Specifications:

particle counter

  • Measurement channels: 6
  • Channel sizes: 0.3 μm, 0.5 μm, 1.0 μm, 2.5 μm, 5.0 μm, 10.0 μm
  • Counting modes: concentration, cumulative, differential
  • Counting efficiency: 50% at 0.3 μm; 100% for particles with sizes of >, and 0.45 μm
  • Flow rate: 2.83 l/min (0.1 ft³/min), driven by an internal pump
  • Number of zeros: < 1 share / 5 min
  • Coincidence loss: 5%, 2 million particles per ft³ (28.3 liters)
  • Light source: Class 3B laser, wavelength 780 nm, 90 mW
  • Sample Inlet: Isokinetic Probe

air temperature

  • Measuring range: 0 °C to 50 °C (32 °F to 122 °F)
  • Accuracy: ±0.5 °C (0.9 °F) at temperatures between 10 °C and 40 °C (50 °F and 104 °F), ±1.0 °C (1.8 °F) at other temperatures

humidity

  • Measurement range: 0 to 100% relative humidity
  • Accuracy: ±3% from 40% to 60%, ±3.5% from 20% to 40% and from 60% to 80%, ±5% from 0% to 20% and from 80% to 100%

dew point temperature

  • Measurement range: -30 °C to 100 °C (-22 °F to 199 °F)
  • Accuracy: ±0.5 °C (0.9 °F) at temperatures between 10 °C and 40 °C (50 °F and 104 °F), ±1.0 °C (1.8 °F) at other temperatures

wet bulb temperature

  • Measuring range: 0 °C to 80 °C (32 °F to 176 °F)
  • Accuracy: ±1.0 °C (1.8 °F)

database

  • Measurement data: 5,000 data sets in internal flash memory (optional expansion via MicroSD card, up to 8 GB)
  • Photo: JPEG format, resolution 640 x 480 pixels
  • Video: 3GP format, resolution 320 x 240 pixels

Interior Design

  • Display: 2.8-inch color LCD, 320 x 240 pixels, with backlight
  • Features: display of maximum, minimum, and average values; data hold function; alarm function; language selection; °C–°F conversion, photo and video recording, adjustable automatic screen timeout (90 seconds, 2 minutes, or 4 minutes) and device shutdown (3 minutes, 15 minutes, or 60 minutes)
  • Memory expansion: MicroSD card slot
  • PC interfaces: USB port

Power source:

  • Battery type: Li-Ion polymer
  • Working hours: approximately 4 hours of continuous work
  • Charging time: about 2 hours with an AC adapter

Physical characteristics:

  • Dimensions (W x L x H): 57 x 75 x 240 mm
  • Weight: 570 g

Optional :

First, use the software included in the package to read the data stored on the device, such as images, Excel spreadsheets, or graphics. Now copy and paste the results into one of the ready-made report templates in the MultiMeasure Studio PRO software (Download MultiMeasure Studio STD), which allows you to quickly and easily create professional measurement reports. The included text modules (currently available only in the German version) and sample reports can be edited as desired, and by combining them, you can create new, user-defined templates at any time.

Package Contents: measuring device, mini tripod, carrying case, zero filter and connecting hose, charger, USB cable, software, user manuals, calibration certificate

Advantages:

  • Particle Counter with a Long-Life Laser Diode
  • Complies with the ISO 21501-4 standard
  • 6 particle-size channels ranging from 0.3 to 10 μm
  • Measuring filter efficiency
  • Determines the size fractions and concentration of airborne particles
  • It also measures environmental climate parameters such as humidity, air temperature, dew point, and wet-bulb temperature
  • Data logger with 5,000 readings of internal memory (optional memory expansion via microSD card up to 8 GB)
  • Integrated digital camera for photo and video documentation in the measurement environment
  • An additional color indicator display with an automatic audible alarm for rapid detection of critical particle concentrations
  • 2.8-inch backlit color LCD screen for simultaneous display of all measured parameters
  • Ergonomic one-handed control
  • Tripod thread for long-term measurements on a tripod
  • Exporting Computer Measurement Data via a USB Connection
  • Delivery with a calibration certificate (optional)
particle concentration
number of channels 6
Channel sizes 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
Counting Modes Concentration, cumulative, differential
Counting efficiency 50% at 0.3 µm; 100% for particles with sizes of > 0.45 µm
flow rate 2.83 l/m (0.1 ft³/min), driven by an internal pump
0 < 1 share / 5 min
loss of chance 5%, 2 million particles per cubic foot (28.3 liters)
detector type Measurement of scattered light
sample inlet Isokinetic probe
air temperature
Measurement range min [°C] 0
Measurement range, max [°C] 50
Measurement range min [°F] 32
Maximum measurement range [°F] 122
Accuracy ± 10 °C – 40 °C [°C] 0.5
Temperature below 10 °C – temperature above 40 °C [°C] 1
Accuracy ± 50°F – 104°F [°F] 0.9
Temperature below 50 °F – temperature above 104 °F [°F] 1.8
relative humidity
Measurement range min [%] 0
Maximum measurement range [%] 100
Accuracy 40%–60% [%] 3
Accuracy 20%–40% [%] 3.5
Accuracy 60%–80% [%] 3.5
Accuracy 0%–20% [%] 5
Accuracy 80%–100% [%] 5
dew point temperature
Measurement range min [°C] 0
Measurement range, max [°C] 50
Measurement range min [°F] 32
Maximum measurement range [°F] 122
Accuracy ± 10 °C – 40 °C [°C] 0.5
Accuracy ± 10 °C – 40 °C [°C] 1
Accuracy ± 50°F – 104°F [°F] 0.9
Accuracy ± 50°F – 104°F [°F] 1.8
wet bulb temperature
Measurement range min [°C] 0
Measuring range, max [°C] 80
Measurement range min [°F] 32
Maximum measurement range [°F] 176
Accuracy ± [°C] 1
Accuracy ± [°F] 1.8
screen
LCD
color
memory management
Internal flash memory up to 5,000 data sets
Expanded storage (MicroSD, optional) – (up to 16 GB)
Photo file format JPEG (640×480)
in video format 3GP (320×240)
interfaces
USB
Environmental Conditions
Operating – minimum temperature [°C] 0
Operating – maximum temperature [°C] 50
Operating Conditions – Maximum Relative Humidity (Non-Condensing) [%] 80
Storage – min temperature [°C] -10
Storage – maximum temperature [°C] 60
Dimensions
Length (without packaging) [mm] 240
Width (without packaging) [mm] 58
Height (without packaging) [mm] 75
Weight
(without packaging) [kg] 0.435
Package Contents
Standard Scope of Delivery
gauge
battery(ies)
charger
Zero filter with connecting hose
mini tripod
transport case
USB cable
software
user manual
calibration certificate
MEASURABLE QUANTITIES AND FUNCTIONS
internal sensors
Particle concentration [n/L]
Particle concentration [n/f³]
relative humidity [%]
Air Temperature [°C]
Dew point temperature [°C]
Wet-bulb temperature [°C]
Air Temperature [°F]
Dew point temperature [°F]
Wet Bulb Temperature [°F]
Features and Equipment
screen backlight
¼-inch tripod thread
Displaying the Maximum Value
Displaying the Minimum Value
Measured Value Hold Function
switchable time-weighted averaging
Audible Alert Function
automatic shut-off
center screen
language selection
°C to °F Conversion
saving a photo
video recording
automatic screen shutdown
Optical alarm function
calibration function