Digital Multimeter / integrated multimeter / voltage / current / frequency / resistance / temperature / capacitance / diode test / continuity test
The Digital Multimeter was developed for practical and mobile use and can be used universally thanks to its diverse measurement functions. Our Digital Multimeter reliably measures voltage, current, frequency, resistance, temperature, capacitance and offers a diode and continuity test. The MODE key makes it easy to switch between digital multimeter and Digital Multimeter mode. With a bandwidth of 10 MHz and a fast sampling rate of 48 MSa/s, it ensures precise and quick data acquisition.
The device supports the storage of waveform data which can be exported as images and transferred to a PC. An LED backlight with adjustable brightness and power-off time as well as multifunctional keys make operation easier for the user. With a rechargeable battery via the C-type interface and a long standby time, the Digital Multimeter multimeter is ideal for long working hours, while the measured values are updated three times per second to always provide up-to-date data. The hand-held Digital Multimeter multimeter is an ideal companion for service technicians on site or in any electrical workshop.
Highlights
- multimeter with oscilloscope functions
- bandwidth 10 MHz
- sampling rate up to 48 MSa/s
- LC display with 4 brightness levels
- auto measurement range selection
- USB-C interface
Technical specifications
- Direct voltage DC — Measuring range: 0 … 9,999 mV
- Direct voltage DC — Resolution: 0,001 mV
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct voltage DC — Measuring range: 10 … 99,99 mV
- Direct voltage DC — Resolution: 0,01 mV
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct voltage DC — Measuring range: 100 … 999,9 mV
- Direct voltage DC — Resolution: 0,1 mV
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct voltage DC — Measuring range: 1 … 9,999 V
- Direct voltage DC — Resolution: 0,001 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct voltage DC — Measuring range: 10 … 99,99 V
- Direct voltage DC — Resolution: 0,01 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct voltage DC — Measuring range: 100 … 999,9 V
- Direct voltage DC — Resolution: 0,1 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
- Direct current DC — Measuring range: 0 … 9999 µA
- Direct current DC — Resolution: 1 µA
- Direct current DC — Accuracy: ±(0.8 % of Rd +3 digits)
- Direct current DC — Measuring range: 10 … 99,99 mA
- Direct current DC — Resolution: 0,01 mA
- Direct current DC — Accuracy: ±(0.8 % of Rd +3 digits)
- Direct current DC — Measuring range: 100 … 999,9 mA
- Direct current DC — Resolution: 0,1 mA
- Direct current DC — Accuracy: ±(1% of Rd +3 digits)
- Direct current DC — Measuring range: 1 … 9,999 A
- Direct current DC — Resolution: 0,001 A
- Direct current DC — Accuracy: ±(1% of Rd +3 digits)
- Capacity — Measuring range: 0 … 9,999 nF
- Capacity — Resolution: 0,001 nF
- Capacity — Accuracy: ±(5 % of Rd +20 digits)
- Capacity — Measuring range: 10 … 99,99 nF
- Capacity — Resolution: 0,01 nF
- Capacity — Accuracy: ±(2 % of Rd +5 digits)
- Capacity — Measuring range: 100 … 999,9 nF
- Capacity — Resolution: 0,1 nF
- Capacity — Accuracy: ±(2 % of Rd +5 digits)
- Capacity — Measuring range: 1 … 9,999 µF
- Capacity — Resolution: 0,001 µF
- Capacity — Accuracy: ±(2 % of Rd +5 digits)
- Capacity — Measuring range: 10 … 99,99 µF
- Capacity — Resolution: 0,01 µF
- Capacity — Accuracy: ±(2 % of Rd +5 digits)
- Capacity — Measuring range: 100 … 999,9 µF
- Capacity — Resolution: 0,1 µF
- Capacity — Accuracy: ±(5 % of Rd +5 digits)
- Capacity — Measuring range: 1 … 9,999 mF
- Capacity — Resolution: 0,001 mF
- Capacity — Accuracy: ±(5 % of Rd +5 digits)
- Capacity — Measuring range: 10 … 99,99 mF
- Capacity — Resolution: 0,01 mF
- Capacity — Accuracy: ±(5 % of Rd +5 digits)
- AC voltage — Measuring range: 0 … 9,999 mV
- AC voltage — Resolution: 0,001 mV
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 10 … 99,99 mV
- AC voltage — Resolution: 0,01 mV
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 100 … 999,9 mV
- AC voltage — Resolution: 0,1 mV
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 1 … 9,999 V
- AC voltage — Resolution: 0,001 V
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 10 … 99,99 V
- AC voltage — Resolution: 0,01 V
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 100 … 750 V
- AC voltage — Resolution: 0,1 V
- AC voltage — Accuracy: ±(1% of Rd +3 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 0 … 9999 µA
- Alternating current AC — Resolution: 1 µA
- Alternating current AC — Accuracy: ±(1% of Rd +3 digits)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 10 … 99,99 mA
- Alternating current AC — Resolution: 0,01 mA
- Alternating current AC — Accuracy: ±(1% of Rd +3 digits)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 100 … 999,9 mA
- Alternating current AC — Resolution: 0,1 mA
- Alternating current AC — Accuracy: ±(1.2 % of Rd +3 digits)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 1 … 9,999 A
- Alternating current AC — Resolution: 0,001 A
- Alternating current AC — Accuracy: ±(1.2 % of Rd +3 digits)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Resistance — Measuring range: 0 … 99,99 Ω
- Resistance — Resolution: 0,01 Ω
- Resistance — Accuracy: ±(1% of Rd +3 digits)
- Resistance — Measuring range: 100 … 999,9 Ω
- Resistance — Resolution: 0,1 Ω
- Resistance — Accuracy: ±(0.5 % of Rd +3 digits)
- Resistance — Measuring range: 1000 Ω … 9,999 kΩ
- Resistance — Resolution: 0,001 kΩ
- Resistance — Accuracy: ±(0.5 % of Rd +3 digits)
- Resistance — Measuring range: 10 … 99,99 kΩ
- Resistance — Resolution: 0,01 kΩ
- Resistance — Accuracy: ±(0.5 % of Rd +3 digits)
- Resistance — Measuring range: 100 … 999,9 kΩ
- Resistance — Resolution: 0,1 kΩ
- Resistance — Accuracy: ±(0.5 % of Rd +3 digits)
- Resistance — Measuring range: 1000 kΩ … 9,999 M Ω
- Resistance — Resolution: 0,001 mΩ
- Resistance — Accuracy: ±(1.5 % of Rd +3 digits)
- Resistance — Measuring range: 10 … 99,99 M Ω
- Resistance — Resolution: 0,01 mΩ
- Resistance — Accuracy: ±(3 % of Rd +5 digits)
- Frequency — Measuring range: 0 … 99,99 Hz
- Frequency — Resolution: 0,01 Hz
- Frequency — Accuracy: ±(0.1 % of Rd +2 digits)
- Frequency — Measuring range: 100 … 999,9 Hz
- Frequency — Resolution: 0,1 Hz
- Frequency — Accuracy: ±(0.1 % of Rd +2 digits)
- Frequency — Measuring range: 1000 Hz … 9,999 kHz
- Frequency — Resolution: 0,001 kHz
- Frequency — Accuracy: ±(0.1 % of Rd +2 digits)
- Frequency — Measuring range: 10 … 99,99 kHz
- Frequency — Resolution: 0,01 kHz
- Frequency — Accuracy: ±(0.1 % of Rd +2 digits)
- Frequency — Measuring range: 100 … 999,9 kHz
- Frequency — Resolution: 0,1 kHz
- Frequency — Accuracy: ±(0.1 % of Rd +2 digits)
- Temperature — Measuring range: -20 … +1000 °C
- Temperature — Resolution: 1 °C
- Temperature — Accuracy: ±(2.5 % of Rd +5 digits)
- Temperature — Measuring range: -4 … +1832 °F
- Temperature — Resolution: 1 °F
- Temperature — Accuracy: ±(2.5 % of Rd +5 digits)
- Oscilloscope specifications: Number of channels 1
- Oscilloscope specifications — Measuring functions: Period, Frequency, Peak-peak, MAX, MIN, RMS value
- Oscilloscope specifications — Sampling rate: 48 MSa/s
- Oscilloscope specifications: Input impedance 1 M Ω
- Oscilloscope specifications: Probe factors X1, X10
- Oscilloscope specifications: Max. input voltage 150 V
- Oscilloscope specifications: Adjustable sampling rate 1.5 Sa/s … 48 MSa/s
- Oscilloscope specifications: Time base 100 ns/div … 20 s/div
- Oscilloscope specifications — Accuracy: 20 ppm
- Oscilloscope specifications: Vertical sensitivity 20 mV/div … 10 V/div
- Oscilloscope specifications: Rise time 10 ns
- Oscilloscope specifications: DC gain accuracy±3%
- General technical data — Display type: LCD
- General technical data — Display size: 2,76 Inch
- General technical data: Measuring rate 3 Hz
- Storage medium Internal memory — Storage capacity: 15 MB
- Memory information Screenshot on keystroke — Interface: USB-C, BNC
- Memory information Screenshot on keystroke: Automatic power-off from…to 15 … 120 min.
- Memory information Screenshot on keystroke: Safety standard CAT III 600V, CAT II 1000V
- Memory information Screenshot on keystroke: Fuse(s)Microfuse 10 A
- Edge: rising, falling — Menu language: English, Chinese, English (GB)
- Edge: rising, falling — Protection class (device): IP20
- Edge: rising, falling — Power supply 100 … 240 V AC: 50/60 Hz
- Edge: rising, falling — (Rechargeable) battery: 1 x 3,7 V 18650 , lithium
- Edge: rising, falling — Capacity: 2000 mAh
- Edge: rising, falling — Operating conditions: 0 … 40 °C , 0 … 75 % RH
- Edge: rising, falling — Storage conditions: -20 … 60 °C , 0 … 80 % RH
- Edge: rising, falling — Dimensions: ( L x W x H )175 x 90 x 40 mm
- Edge: rising, falling — Weight: 352 g
Delivery scope
- 1 x Digital Multimeter PCE-OC 15
- 1 x set of test leads
- 1 x Digital Multimeter probe
- 1 x temperature sensor
- 1 x USB-C cable
- 1 x user manual
- 1 x probe accessories