Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-LT 15 digital multimeter

Digital Multimeter PCE-LT 15 LAN tester for fast network cable inspection / Combination device consisting of LAN tester and multimeter with voltage and resistance measurement. The LAN tester PCE-LT 15 is a combination device which detects configuration errors in the network and at the same time can be used as a multimeter.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Ekraan LCD
Eraldusvõime Alalispinge: 0,1 mV, Alalispinge: 1 mV, Alalispinge: 1 V, Alalispinge: 10 mV, Alalispinge: 100 mV, Takistus: 0,1 Ω, Takistus: 1 kΩ, Takistus: 1 Ω, Takistus: 10 kΩ, Takistus: 10 Ω, Takistus: 100 Ω, Vahelduvpinge: 0,1 mV, Vahelduvpinge: 1 mV, Vahelduvpinge: 1 V, Vahelduvpinge: 10 mV, Vahelduvpinge: 100 mV
Weight (kg) 0.245
Kaitseklass IP20
Liides Ethernet
Mõõtefunktsioonid Diooditest, Näidu hoidmine
Mõõdetav suurus Vahelduvpinge
Dimensions 165 x 82 x 45 mm
Toiteallikas Patarei
Töötingimused (% RH) 0 - 80
Töötingimused (°C) 0 - 40

Digital Multimeter PCE-LT 15 LAN tester for fast network cable inspection / Combination device consisting of LAN tester and multimeter with voltage and resistance measurement

The LAN tester PCE-LT 15 is a combination device which detects configuration errors in the network and at the same time can be used as a multimeter. Thus, the periphery of a network can be quickly checked with the LAN tester. With the LAN tester PCE-LT 15 it is possible to check 8-pin data cables with RJ-45 connectors for continuity, open connections, and short circuits. In addition to the LAN test function, the LAN Tester can also measure DC and AC voltages.

With the LAN tester, which also serves as a multimeter, it is possible to perform a continuity test with buzzer and a diode test. The LAN tester is also a device that identifies the most common network installation errors. The two-row LEDs successively indicate the pin assignment of the cable to be tested. In the event of a short circuit, more than two LEDs light up simultaneously.

Technical specifications

  • Direct voltage DC — Measuring range: 0 … 400 mV
  • Direct voltage DC — Resolution: 0,1 mV
  • Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
  • Direct voltage DC — Measuring range: 0 … 4 V
  • Direct voltage DC — Resolution: 1 mV
  • Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
  • Direct voltage DC — Measuring range: 0 … 40 V
  • Direct voltage DC — Resolution: 10 mV
  • Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
  • Direct voltage DC — Measuring range: 0 … 400 V
  • Direct voltage DC — Resolution: 100 mV
  • Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
  • Direct voltage DC — Measuring range: 0 … 1000 V
  • Direct voltage DC — Resolution: 1 V
  • Direct voltage DC — Accuracy: ±(0.5 % of Rd +3 digits)
  • AC voltage — Measuring range: 0 … 400 mV
  • AC voltage — Resolution: 0,1 mV
  • AC voltage — Accuracy: ±(1 % of Rd +5 digits)
  • AC voltage — Measuring range: 0 … 4 V
  • AC voltage — Resolution: 1 mV
  • AC voltage — Accuracy: ±(1 % of Rd +5 digits)
  • AC voltage — Measuring range: 0 … 40 V
  • AC voltage — Resolution: 10 mV
  • AC voltage — Accuracy: ±(1 % of Rd +5 digits)
  • AC voltage — Measuring range: 0 … 400 V
  • AC voltage — Resolution: 100 mV
  • AC voltage — Accuracy: ±(1 % of Rd +5 digits)
  • AC voltage — Measuring range: 0 … 750 V
  • AC voltage — Resolution: 1 V
  • AC voltage — Accuracy: ±(1 % of Rd +5 digits)
  • Resistance — Measuring range: 0 … 400 Ω
  • Resistance — Resolution: 0,1 Ω
  • Resistance — Accuracy: ±(1.2 % of Rd +3 digits)
  • Resistance — Measuring range: 0 … 4 kΩ
  • Resistance — Resolution: 1 Ω
  • Resistance — Accuracy: ±(1.2 % of Rd +3 digits)
  • Resistance — Measuring range: 0 … 40 kΩ
  • Resistance — Resolution: 10 Ω
  • Resistance — Accuracy: ±(1.2 % of Rd +3 digits)
  • Resistance — Measuring range: 0 … 400 kΩ
  • Resistance — Resolution: 100 Ω
  • Resistance — Accuracy: ±(1.2 % of Rd +3 digits)
  • Resistance — Measuring range: 0 … 4 M Ω
  • Resistance — Resolution: 1 kΩ
  • Resistance — Accuracy: ±(1.2 % of Rd +3 digits)
  • Resistance — Measuring range: 0 … 40 M Ω
  • Resistance — Resolution: 10 kΩ
  • Resistance — Accuracy: ±(2% v.Mw. +4 Digits)
  • General technical data — Measuring functions: Continuity test, HOLD
  • General technical data — Display type: LCD
  • General technical data — Display size: 1,9 Inch
  • General technical data — Interface: RJ45
  • General technical data: Safety standard CAT III 600V
  • General technical data — Menu language: English, English (GB)
  • General technical data — Protection class (device): IP20
  • General technical data — (Rechargeable) battery: 1 x 9 V 9V block , Alkali-manganese
  • General technical data — Capacity: 640 mAh
  • General technical data — Operating conditions: 0 … 40 °C , 0 … 80 % RH
  • General technical data — Storage conditions: -10 … 50 °C , 0 … 80 % RH
  • General technical data — Dimensions: ( L x W x H )165 x 82 x 45 mm
  • General technical data — Other dimensions: Remote unit: 75 x 30 x 25 mm
  • General technical data — Weight: 245 g
  • General technical data: Other weights Remote unit: 30 g

Documents

FAQ