Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-LT 12 digital multimeter

Digital multimeterPCE-LT 12 Voltage tester with many measuring functions / For electricians and IT employees / Analysis of network connection cables / Telephone connection test / Voltage and current measurement / NCV / backlight. The voltage tester is a versatile measuring instrument.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Ekraan LCD
Eraldusvõime Alalispinge: 0,01 V, Alalispinge: 0,1 mV, Alalispinge: 0,1 V, Alalispinge: 1 mV, Alalispinge: 1 V, Alalisvool: 0,001 A, Alalisvool: 0,01 A, Alalisvool: 0,01 mA, Alalisvool: 0,1 mA, Alalisvool: 0,1 µA, Alalisvool: 1 µA, Takistus: 0,001 kΩ, Takistus: 0,001 MΩ, Takistus: 0,01 kΩ, Takistus: 0,01 MΩ, Takistus: 0,1 kΩ, Takistus: 0,1 Ω, Vahelduvpinge: 0,01 V, Vahelduvpinge: 0,1 mV, Vahelduvpinge: 0,1 V, Vahelduvpinge: 1 mV, Vahelduvpinge: 1 V, Vahelduvvool: 0,001 A, Vahelduvvool: 0,01 A, Vahelduvvool: 0,01 mA, Vahelduvvool: 0,1 mA, Vahelduvvool: 0,1 µA, Vahelduvvool: 1 µA
Weight (kg) 0.37
Kaitseklass IP20
Mõõtefunktsioonid Diooditest, Maksimaalväärtus, Näidu hoidmine
Mõõdetav suurus Alalispinge, Alalisvool, Takistus, Vahelduvpinge, Vahelduvvool
Dimensions 190 x 90 x 53 mm
Toiteallikas Patarei
Töötingimused (% RH) 0 - 80
Töötingimused (°C) 0 - 40

Digital multimeterPCE-LT 12 Voltage tester with many measuring functions / For electricians and IT employees / Analysis of network connection cables / Telephone connection test / Voltage and current measurement / NCV / backlight

The voltage tester is a versatile measuring instrument. In addition to the standard voltage and current measurements, the voltage tester also has a network analysis. With this network analysis, the voltage tester can be used to check, for example, LAN connections for their correct wiring and function. Telephone connections can also be checked for their function with this voltage tester. If cables can not be found again, the voltage tester also helps here.

Thanks to the cable finder function of the voltage tester, the operator can find the required cable in no time at all. To do this, the voltage tester must be connected to the connection of a cable. The voltage tester now acts as a transmitter. With the supplied receiver you can now easily find the desired cable in, for example, a wiring harness or behind walls with the voltage tester.

To check whether a voltage is applied to a cable, the voltage tester has an NCV (Not Connected Voltage) function. With this function, the voltage tester must only be held to the line. Both acoustically and visually, the voltage tester signals the operator that a voltage is applied to the line. Thanks to this contactless measuring function, the voltage tester reduces accidents at work due to electric shock.

Technical specifications

  • Direct voltage DC — Measuring range: 0 … 200 mV
  • Direct voltage DC — Resolution: 0,1 mV
  • Direct voltage DC — Accuracy: ±(0.5% +5 digits)
  • Direct voltage DC — Measuring range: 0 … 2 V
  • Direct voltage DC — Resolution: 1 mV
  • Direct voltage DC — Accuracy: ±(0.5% +5 digits)
  • Direct voltage DC — Measuring range: 0 … 20 V
  • Direct voltage DC — Resolution: 0,01 V
  • Direct voltage DC — Accuracy: ±(0.5% +5 digits)
  • Direct voltage DC — Measuring range: 0 … 200 V
  • Direct voltage DC — Resolution: 0,1 V
  • Direct voltage DC — Accuracy: ±(0.5% +5 digits)
  • Direct voltage DC — Measuring range: 0 … 1000 V
  • Direct voltage DC — Resolution: 1 V
  • Direct voltage DC — Accuracy: ±(0.8% +5 digits)
  • Direct current DC — Measuring range: 0 … 200 µA
  • Direct current DC — Resolution: 0,1 µA
  • Direct current DC — Accuracy: ±(1.2 % +5 digits)
  • Direct current DC — Measuring range: 0 … 2000 µA
  • Direct current DC — Resolution: 1 µA
  • Direct current DC — Accuracy: ±(1.2 % +5 digits)
  • Direct current DC — Measuring range: 0 … 20 mA
  • Direct current DC — Resolution: 0,01 mA
  • Direct current DC — Accuracy: ±(1.2 % +5 digits)
  • Direct current DC — Measuring range: 0 … 200 mA
  • Direct current DC — Resolution: 0,1 mA
  • Direct current DC — Accuracy: ±(1.2 % +5 digits)
  • Direct current DC — Measuring range: 0 … 2 A
  • Direct current DC — Resolution: 0,001 A
  • Direct current DC — Accuracy: ±(2% +5 digits)
  • Direct current DC — Measuring range: 0 … 20 A
  • Direct current DC — Resolution: 0,01 A
  • Direct current DC — Accuracy: ±(2% +5 digits)
  • AC voltage — Measuring range: 0 … 200 mV
  • AC voltage — Resolution: 0,1 mV
  • AC voltage — Accuracy: ±(0.8% +5 digits)
  • AC voltage — Frequency: range 40 … 400 Hz
  • AC voltage — Measuring range: 0 … 2 V
  • AC voltage — Resolution: 1 mV
  • AC voltage — Accuracy: ±(0.8% +5 digits)
  • AC voltage — Frequency: range 40 … 400 Hz
  • AC voltage — Measuring range: 0 … 20 V
  • AC voltage — Resolution: 0,01 V
  • AC voltage — Accuracy: ±(0.8% +5 digits)
  • AC voltage — Frequency: range 40 … 400 Hz
  • AC voltage — Measuring range: 0 … 200 V
  • AC voltage — Resolution: 0,1 V
  • AC voltage — Accuracy: ±(0.8% +5 digits)
  • AC voltage — Frequency: range 40 … 400 Hz
  • AC voltage — Measuring range: 0 … 750 V
  • AC voltage — Resolution: 1 V
  • AC voltage — Accuracy: ±(0.8% +5 digits)
  • AC voltage — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 200 µA
  • Alternating current AC — Resolution: 0,1 µA
  • Alternating current AC — Accuracy: ±(1.5 % +5 digits)
  • Alternating current AC: Overload Overload protection for µA, mA: 200 mA / 1000V fuse
  • Alternating current AC: Overload protection at A: 10 A / 500V fuse
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 2000 µA
  • Alternating current AC — Resolution: 1 µA
  • Alternating current AC — Accuracy: ±(1.5 % +5 digits)
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 20 mA
  • Alternating current AC — Resolution: 0,01 mA
  • Alternating current AC — Accuracy: ±(1.5 % +5 digits)
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 200 mA
  • Alternating current AC — Resolution: 0,1 mA
  • Alternating current AC — Accuracy: ±(1.5 % +5 digits)
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 2 A
  • Alternating current AC — Resolution: 0,001 A
  • Alternating current AC — Accuracy: ±(3% +5 digits)
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Alternating current AC — Measuring range: 0 … 20 A
  • Alternating current AC — Resolution: 0,01 A
  • Alternating current AC — Accuracy: ±(3% +5 digits)
  • Alternating current AC — Frequency: range 40 … 400 Hz
  • Resistance — Measuring range: 0 … 200 kΩ
  • Resistance — Resolution: 0,1 Ω
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • Resistance — Measuring range: 0 … 2 kΩ
  • Resistance — Resolution: 0,001 kΩ
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • Resistance — Measuring range: 0 … 20 kΩ
  • Resistance — Resolution: 0,01 kΩ
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • Resistance — Measuring range: 0 … 200 kΩ
  • Resistance — Resolution: 0,1 kΩ
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • Resistance — Measuring range: 0 … 2 M Ω
  • Resistance — Resolution: 0,001 M Ω
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • Resistance — Measuring range: 0 … 20 M Ω
  • Resistance — Resolution: 0,01 M Ω
  • Resistance — Accuracy: ±(1.0% +5 digits)
  • General technical data — Measuring functions: MAX, HOLD, Continuity test
  • General technical data — Display type: LCD with backlight
  • General technical data — Display size: 2,4 Inch
  • General technical data: Automatic power-off 15 min
  • General technical data: Fuse(s)F10A / 500V, F200mA/1000A
  • General technical data — Measuring range: selection Automatic, Manual
  • Diode test Displays the forward voltage.: max. input current µA: 2000 µA
  • Diode test Displays the forward voltage.: mA: 200 mA
  • Diode test Displays the forward voltage.: A: 10 A
  • Diode test Displays the forward voltage.: Max. input voltage 750V AC
  • Diode test Displays the forward voltage.: 1000V DC
  • Diode test Displays the forward voltage. — Menu language: English, English (GB)
  • Diode test Displays the forward voltage. — Protection class (device): IP20
  • Diode test Displays the forward voltage. — (Rechargeable) battery: 2 x 9 V 9V block , Alkali-manganese
  • Diode test Displays the forward voltage. — Capacity: 640 mAh
  • Diode test Displays the forward voltage. — Operating conditions: 0 … 40 °C , 0 … 80 % RH
  • Diode test Displays the forward voltage. — Storage conditions: -10 … 50 °C , 0 … 80 % RH
  • Diode test Displays the forward voltage. — Dimensions: ( L x W x H )190 x 90 x 53 mm
  • Diode test Displays the forward voltage. — Other dimensions: Receiver: L 240 x W 43 x H 24 mm
  • Diode test Displays the forward voltage. — Weight: 370 g
  • Diode test Displays the forward voltage.: Other weights Receiver: 70 g

Documents

FAQ