Digital Multimeter PCE-DC 50 Clamp meter with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth interface / Rubberized housing / Display hold / Automatic switch-off / Test lead max. 48 mm / Many measuring functions
The clamp meter PCE-DC 50 is a measuring device for measuring currents of up to 1000 A AC / DC. In addition to current measurement, the clamp can also measure and test voltage, frequency, duty cycle, resistance, continuity test, capacitors and diodes. The enclosure diameter of the clamp is 48 mm. Thus, you can also perform measurements on cables with a large cross-section. Thanks to the NCVD function, it is possible to use the measuring clamp to check contactlessly whether a voltage is applied to a cable.
This clamp has an integrated Bluetooth interface. Via this Bluetooth interface a connection to the PC or the smartphone can be established with the measuring pliers. This allows the measured data of the measuring clamp to be stored and analyzed. If the PC does not have a Bluetooth interface to connect the measuring pliers, a suitable Bluetooth adapter is included in the delivery.
Another special feature of the measuring clamp is the measurement of temperatures. Two type-K thermocouples can be connected to the measuring clamp and read out at the same time. Here, temperatures of up to 1000°C / 1832°F can be measured. The housing of the measuring pliers consists of a robust plastic, which is additionally coated with a rubber coating. Thanks to the additional rubber coating, the measuring pliers can easily withstand impacts.
Highlights
- Sample rate 2 Hz
- Cover on the test sockets
- AC A and AC V measurement
- Bluetooth interface
- Cable diameter max. 48 mm
- Temperature measurement via 2 thermocouples
- Automatic shutdown
- Non-contact voltage detection
Technical specifications
- Direct voltage DC — Measuring range: 0 … 500 mV
- Direct voltage DC — Resolution: 0,01 mV
- Direct voltage DC — Accuracy: ±(0.1% v.Mw. +8 digits)
- Direct voltage DC — Measuring range: 0 … 5 V
- Direct voltage DC — Resolution: 0,0001 V
- Direct voltage DC — Accuracy: ±( 0.1% v.Mw. +4 digits)
- Direct voltage DC — Measuring range: 0 … 50 V
- Direct voltage DC — Resolution: 0,001 V
- Direct voltage DC — Accuracy: ±( 0.1% v.Mw. +4 digits)
- Direct voltage DC — Measuring range: 0 … 500 V
- Direct voltage DC — Resolution: 0,01 V
- Direct voltage DC — Accuracy: ±( 0.1% v.Mw. +4 digits)
- Direct voltage DC — Measuring range: 0 … 600 V
- Direct voltage DC — Resolution: 0,1 V
- Direct voltage DC — Accuracy: ±( 0.5% v.Mw. +4 digits)
- Direct current DC — Measuring range: 0 … 500 µA
- Direct current DC — Resolution: 0,01 µA
- Direct current DC — Accuracy: ±(1 % of Rd +6 digits)
- Direct current DC — Measuring range: 0 … 5000 µA
- Direct current DC — Resolution: 0,1 µA
- Direct current DC — Accuracy: ±(1 % of Rd +6 digits)
- Direct current DC — Measuring range: 0 … 50 A
- Direct current DC — Resolution: 0,01 A
- Direct current DC — Accuracy: ±(2.5 % of Rd +5 digits)
- Direct current DC — Measuring range: 0 … 1000 A
- Direct current DC — Resolution: 0,1 A
- Direct current DC — Accuracy: ±(2.5% +30 Digits)
- Capacity — Measuring range: 0 … 500 nF
- Capacity — Resolution: 0,01 nF
- Capacity — Accuracy: ±(3.5% v.Mw. +40 digits)
- Capacity — Measuring range: 0 … 5000 nF
- Capacity — Resolution: 0,1 nF
- Capacity — Accuracy: ±(3.5% v.Mw. +10 Digits)
- Capacity — Measuring range: 0 … 50 µF
- Capacity — Resolution: 0,001 µF
- Capacity — Accuracy: ±(3.5% v.Mw. +10 Digits)
- Capacity — Measuring range: 0 … 500 µF
- Capacity — Resolution: 0,01 µF
- Capacity — Accuracy: ±(3.5% v.Mw. +10 Digits)
- Capacity — Measuring range: 0 … 5 mF
- Capacity — Resolution: 0,0001 mF
- Capacity — Accuracy: ±(5% v.Mw. +10 Digits)
- AC voltage — Measuring range: 0 … 500 mV
- AC voltage — Resolution: 0,01 mV
- AC voltage — Accuracy: ±( 0.8% +9 digits)
- AC voltage — Frequency: range 50 … 1000 Hz
- AC voltage — Measuring range: 0 … 5 V
- AC voltage — Resolution: 0,0001 V
- AC voltage — Accuracy: ±(1% v.Mw. +30 Digits)
- AC voltage — Frequency: range 50 … 1000 Hz
- AC voltage — Measuring range: 0 … 50 V
- AC voltage — Resolution: 0,001 V
- AC voltage — Accuracy: ±(1% v.Mw. +30 Digits)
- AC voltage — Frequency: range 50 … 1000 Hz
- AC voltage — Measuring range: 0 … 500 V
- AC voltage — Resolution: 0,01 V
- AC voltage — Accuracy: ±(1% v.Mw. +30 Digits)
- AC voltage — Frequency: range 50 … 1000 Hz
- AC voltage — Measuring range: 0 … 600 V
- AC voltage — Resolution: 0,1 V
- AC voltage — Accuracy: ±(1% v.Mw. +30 Digits)
- AC voltage — Frequency: range 50 … 1000 Hz
- Alternating current AC — Measuring range: 0 … 500 µA
- Alternating current AC — Resolution: 0,01 µA
- Alternating current AC — Accuracy: ±(1.5% v.Mw. +30 Digits)
- Alternating current AC — Frequency: range 50 … 1000 Hz
- Alternating current AC — Measuring range: 0 … 5000 µA
- Alternating current AC — Resolution: 0,1 µA
- Alternating current AC — Accuracy: ±(1.5% v.Mw. +30 Digits)
- Alternating current AC — Frequency: range 50 … 1000 Hz
- Alternating current AC — Measuring range: 0 … 50 A
- Alternating current AC — Resolution: 0,01 A
- Alternating current AC — Accuracy: ±(2.5% v.Mw. +30 Digits)
- Alternating current AC — Frequency: range 50 … 1000 Hz
- Alternating current AC — Measuring range: 0 … 1000 A
- Alternating current AC — Resolution: 0,1 A
- Alternating current AC — Accuracy: ±(2.8% v.Mw. +30 Digits)
- Alternating current AC — Frequency: range 50 … 1000 Hz
- Resistance — Measuring range: 0 … 500 Ω
- Resistance — Resolution: 0,01 Ω
- Resistance — Accuracy: ±(1% v.Mw. +9 Digits)
- Resistance — Measuring range: 0 … 5 kΩ
- Resistance — Resolution: 0,0001 kΩ
- Resistance — Accuracy: ±(1 % of Rd +5 digits)
- Resistance — Measuring range: 0 … 50 kΩ
- Resistance — Resolution: 0,001 kΩ
- Resistance — Accuracy: ±(1 % of Rd +5 digits)
- Resistance — Measuring range: 0 … 500 kΩ
- Resistance — Resolution: 0,01 kΩ
- Resistance — Accuracy: ±(1 % of Rd +5 digits)
- Resistance — Measuring range: 0 … 5 M Ω
- Resistance — Resolution: 0,0001 M Ω
- Resistance — Accuracy: ±(2% v.Mw. +10 Digits)
- Resistance — Measuring range: 0 … 50 M Ω
- Resistance — Resolution: 0,001 M Ω
- Resistance — Accuracy: ±(3% v.Mw. +10 Digits)
- Frequency — Measuring range: 0 … 50 Hz
- Frequency — Resolution: 0,001 Hz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 500 Hz
- Frequency — Resolution: 0,01 Hz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 5 kHz
- Frequency — Resolution: 0,0001 kHz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 50 kHz
- Frequency — Resolution: 0,001 kHz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 500 kHz
- Frequency — Resolution: 0,01 kHz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 5 MHz
- Frequency — Resolution: 0,0001 MHz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Frequency — Measuring range: 0 … 10 MHz
- Frequency — Resolution: 0,001 kHz
- Frequency — Accuracy: ±(0.3% v.Mw. +2 Digits)
- Temperature — Measuring range: -100 … +1000 °C
- Temperature — Resolution: 0,1 °C
- Temperature — Accuracy: ±(1% v.Mw. +2.5°C)
- Temperature — Measuring range: -148 … +1832 °F
- Temperature — Resolution: 0,18 °F
- Temperature — Accuracy: ±(1% of measured value + 4.5°F)
- General technical data — Measuring functions: MIN, MAX, HOLD
- General technical data — Frequency: 10 … 10000 Hz
- General technical data — Display type: LCD with backlight
- General technical data — Display size: 1,8 Inch
- General technical data: Measuring rate 2 Hz
- General technical data — Interface: Wireless
- General technical data: Standard(s)IEC 1010-1, EN 61010-1
- General technical data: Maximum cable diameter 48 mm
- General technical data: Automatic power-off 30 min
- General technical data: Bandwidth 50 … 400 kHz
- General technical data: Safety standard CAT III 600V
- General technical data: Fuse(s)500 mA Ceramic Flink
- General technical data: Diode test 0.3 mA / 2.8V DC
- General technical data — Menu language: English, English (GB)
- General technical data — Protection class (device): IP20
- General technical data — (Rechargeable) battery: 1 x 9 V 9V block , Alkali-manganese
- General technical data — Capacity: 640 mAh
- General technical data — Operating conditions: 5 … 40 °C , 0 … 80 % RH
- General technical data — Storage conditions: -20 … 60 °C , 0 … 80 % RH
- General technical data — Dimensions: ( L x W x H )230 x 76 x 40 mm
- General technical data — Weight: 315 g
Delivery scope
- 1 x Digital Multimeter PCE-DC 50
- 1 x Test lead set
- 1 x Transport case
- 1 x PC software
- 1 x Bluetooth adapter
- 2 x Thermocouples type-K
- 1 x 9V block battery