Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-IT 110 insulation tester / insulation meter

Insulation Tester / Insulation Meter / Test voltage up to 1000V / LCD color display / Time display / Data memory / Automatic switch-off. The Insulation Tester / Insulation Meter combines the functions of a fully-fledged digital multimeter with a powerful Insulation Tester / Insulation Meter and is ideal for professional applications in industry, trade and energy supply.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Andmemälu maht 1800 väärtust
Andmemälu tüüp Sisemälu
Anduri tüüp Termopaar
Ekraan LCD
Eraldusvõime Alalispinge: 0,001 V, Alalispinge: 0,01 V, Alalispinge: 0,1 mV, Alalispinge: 0,1 V, Alalispinge: 1 V, Alalisvool: 0,01 A, Alalisvool: 0,1 mA, Alalisvool: 0,1 µA, Isolatsioonitakistus: 0,001 MΩ, Isolatsioonitakistus: 0,01 MΩ, Isolatsioonitakistus: 0,1 MΩ, Isolatsioonitakistus: 1 MΩ, Mahtuvus: 0,001 µF, Mahtuvus: 0,01 nF, Mahtuvus: 0,01 µF, Mahtuvus: 0,1 nF, Mahtuvus: 0,1 µF, Mahtuvus: 1 µF, Sagedus: 0,01 Hz, Takistus: 0,001 kΩ, Takistus: 0,001 MΩ, Takistus: 0,01 MΩ, Takistus: 0,01 Ω, Takistus: 0,1 kΩ, Takistus: 0,1 Ω, Temperatuur: 0,1 °C, Temperatuur: 0,1 °F, Temperatuur: 1 °C, Temperatuur: 1 °F, Vahelduvpinge: 0,001 V, Vahelduvpinge: 0,01 V, Vahelduvpinge: 0,1 V, Vahelduvpinge: 1 V, Vahelduvvool: 0,01 A, Vahelduvvool: 0,1 mA, Vahelduvvool: 0,1 µA
Weight (kg) 0.569
Kaitseklass IP65
Liides Bluetooth
Mõõtefunktsioonid Diooditest, Maksimaalväärtus, Minimaalväärtus, Näidu hoidmine, Tippväärtus
Mõõteintervall Mõõtesagedus 3 Hz, Salvestusintervall 1 s ... 60 min
Mõõdetav suurus Alalispinge, Alalisvool, Isolatsioonitakistus, Mahtuvus, Sagedus, Takistus, Temperatuur, Vahelduvpinge, Vahelduvvool
Dimensions 215 x 100 x 65 mm
Toiteallikas Patarei
Töötingimused (% RH) 0 - 80
Töötingimused (°C) 5 - 40

Insulation Tester / Insulation Meter / Test voltage up to 1000V / LCD color display / Time display / Data memory / Automatic switch-off

The Insulation Tester / Insulation Meter combines the functions of a fully-fledged digital multimeter with a powerful Insulation Tester / Insulation Meter and is ideal for professional applications in industry, trade and energy supply. In addition to measuring voltage, current and resistance, the device also offers frequency and capacitance measurement as well as temperature measurement via the supplied type K thermocouple. The automatic range selection and the 3.5 inch LCD color display enable simple and precise operation. The Insulation Tester / Insulation Meter allows insulation tests with selectable test voltages from 125 V to 1000 V and measures insulation resistances of up to 6000 MΩ. It also supports the measurement of the polarization index (PI) and the absorption ratio (DAR), which enables a well-founded assessment of the insulation quality of cables, motors, control cabinets and electrical systems.

Thanks to the integrated data memory, measurement results can be called up directly on the device for later analysis. The recorded data can be transferred wirelessly to a smartphone or tablet via Bluetooth – particularly practical for documentation and test reports. Other features such as automatic discharge after the measurement, MIN/MAX/PEAK value recording, hold function and a lock button for hands-free operation round off the device. The Insulation Tester / Insulation Meter fulfils the highest safety requirements in accordance with CAT IV 600V / CAT III 1000V and can therefore also be used safely for work in energy distribution and on building technology.

Typical areas of application for this Insulation Tester / Insulation Meter include electrical installation, switch cabinet construction, maintenance of machines and systems, photovoltaic systems, the service sector and technical training centers. With its combination of versatility, precision and modern connectivity, this Insulation Tester / Insulation Meter is a good tool for any professional.

Highlights

  • Insulation test voltages 125V, 250V, 500V, 1000V
  • Measuring functions: HOLD, MIN, MAX, PEAK
  • PI (polarization index), DAR (absorption ratio)
  • High voltage and overload indicator
  • Diode test
  • Automatic discharge
  • Automatic switch-off
  • Locking button
  • Data memory with logger
  • Bluetooth for app connection
  • Connections for Rogowski coil

Technical specifications

  • Direct voltage DC — Measuring range: 0 … 600 mV
  • Direct voltage DC — Resolution: 0,1 mV
  • Direct voltage DC — Accuracy: ±(0.9% +5 digits)
  • Direct voltage DC: Overload 1000 V
  • Direct voltage DC — Measuring range: 600 mV … 6 V
  • Direct voltage DC — Resolution: 0,001 V
  • Direct voltage DC — Accuracy: ±(0.9% +5 digits)
  • Direct voltage DC — Measuring range: 6 … 60 V
  • Direct voltage DC — Resolution: 0,01 V
  • Direct voltage DC — Accuracy: ±(0.9% +5 digits)
  • Direct voltage DC — Measuring range: 60 … 600 V
  • Direct voltage DC — Resolution: 0,1 V
  • Direct voltage DC — Accuracy: ±(1% +5 digits)
  • Direct voltage DC — Measuring range: 600 … 1000 V
  • Direct voltage DC — Resolution: 1 V
  • Direct voltage DC — Accuracy: ±(1% +5 digits)
  • Direct current DC — Measuring range: 0 … 200 µA
  • Direct current DC — Resolution: 0,1 µA
  • Direct current DC — Accuracy: ±(0.9% +8 digits)
  • Direct current DC — Measuring range: 200 µA … 600 mA
  • Direct current DC — Resolution: 0,1 mA
  • Direct current DC — Accuracy: ±(1.2% +3 Digits)
  • Direct current DC — Measuring range: 600 mA … 10 A
  • Direct current DC — Resolution: 0,01 A
  • Direct current DC — Accuracy: ±(1.5 % +5 digits)
  • Capacity — Measuring range: 0 … 60 nF
  • Capacity — Resolution: 0,01 nF
  • Capacity — Accuracy: ±(5% +35 digits)
  • Capacity — Measuring range: 60 … 600 nF
  • Capacity — Resolution: 0,1 nF
  • Capacity — Accuracy: ±(2.5 % +8 digits)
  • Capacity — Measuring range: 600 nF … 6 µF
  • Capacity — Resolution: 0,001 µF
  • Capacity — Accuracy: ±(3% +5 digits)
  • Capacity — Measuring range: 6 … 60 µF
  • Capacity — Resolution: 0,01 µF
  • Capacity — Accuracy: ±(3% +5 digits)
  • Capacity — Measuring range: 60 … 600 µF
  • Capacity — Resolution: 0,1 µF
  • Capacity — Accuracy: ±(3% +5 digits)
  • Capacity — Measuring range: 600 … 6000 µF
  • Capacity — Resolution: 1 µF
  • Capacity — Accuracy: ±(2.5% +20 Digits)
  • Type K temperature — Measuring range: -20 … +600 °C
  • Type K temperature — Resolution: 0,1 °C
  • Type K temperature — Accuracy: ±(3 % of Rd +5 °C)
  • Type K temperature — Measuring range: 600 … 1000 °C
  • Type K temperature — Resolution: 1 °C
  • Type K temperature — Accuracy: ±(3 % of Rd +5 °C)
  • Type K temperature — Measuring range: -4 … +600 °F
  • Type K temperature — Resolution: 0,1 °F
  • Type K temperature — Accuracy: ±(3% v.Mw. +9°C)
  • Type K temperature — Measuring range: 600 … 1832 °F
  • Type K temperature — Resolution: 1 °F
  • Type K temperature — Accuracy: ±(3% v.Mw. +9°C)
  • AC voltage — Measuring range: 0 … 6 V
  • AC voltage — Resolution: 0,001 V
  • AC voltage — Accuracy: ±(1% +5 Digits) @50 … 60 Hz / ±(3% +5 Digits) @61 … 1000 Hz
  • AC voltage: Overload 1000 V
  • AC voltage — Frequency: range 50 … 1000 Hz
  • AC voltage — Measuring range: 6 … 60 V
  • AC voltage — Resolution: 0,01 V
  • AC voltage — Accuracy: ±(1% +5 Digits) @50 … 60 Hz / ±(3% +5 Digits) @61 … 1000 Hz
  • AC voltage — Frequency: range 50 … 1000 Hz
  • AC voltage — Measuring range: 60 … 600 V
  • AC voltage — Resolution: 0,1 V
  • AC voltage — Accuracy: ±(1% +5 Digits) @50 … 60 Hz / ±(3% +5 Digits) @61 … 1000 Hz
  • AC voltage — Frequency: range 50 … 1000 Hz
  • AC voltage — Measuring range: 600 … 1000 V
  • AC voltage — Resolution: 1 V
  • AC voltage — Accuracy: ±(1.2% +5 Digits) @50 … 60 Hz / ±(3% +5 Digits) @61 … 1000 Hz
  • AC voltage — Frequency: range 50 … 1000 Hz
  • Alternating current AC — Measuring range: 0 … 200 µA
  • Alternating current AC — Resolution: 0,1 µA
  • Alternating current AC — Accuracy: ±(1.2% +8 digits)
  • Alternating current AC — Frequency: range 50 … 1000 Hz
  • Alternating current AC — Measuring range: 200 µA … 600 mA
  • Alternating current AC — Resolution: 0,1 mA
  • Alternating current AC — Accuracy: ±(1.2 % +5 digits)
  • Alternating current AC — Frequency: range 50 … 1000 Hz
  • Alternating current AC — Measuring range: 600 mA … 10 A
  • Alternating current AC — Resolution: 0,01 A
  • Alternating current AC — Accuracy: ±(1.5 % +5 digits)
  • Alternating current AC — Frequency: range 50 … 1000 Hz
  • Insulation resistance: Test voltage DC 125V
  • Insulation resistance — Measuring range: 0,125 … 6 M Ω
  • Insulation resistance — Resolution: 0,001 M Ω
  • Insulation resistance — Accuracy: ±(2% +10 Digits)
  • Insulation resistance: Test voltage DC 250V
  • Insulation resistance — Measuring range: 0,25 … 6 M Ω
  • Insulation resistance — Resolution: 0,001 M Ω
  • Insulation resistance — Accuracy: ±(2% +15 Digits) M Ω
  • Insulation resistance: Test voltage DC 500V
  • Insulation resistance — Measuring range: 0,5 … 6 M Ω
  • Insulation resistance — Resolution: 0,001 M Ω
  • Insulation resistance — Accuracy: ±(2% +10 Digits)
  • Insulation resistance: Test voltage DC 1000V
  • Insulation resistance — Measuring range: 1 … 6 M Ω
  • Insulation resistance — Resolution: 0,001 M Ω
  • Insulation resistance — Accuracy: ±(3% +10 Digits)
  • Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V
  • Insulation resistance — Measuring range: 6 … 60 M Ω
  • Insulation resistance — Resolution: 0,01 M Ω
  • Insulation resistance — Accuracy: ±(2% +10 Digits)
  • Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V
  • Insulation resistance — Measuring range: 60 … 600 M Ω
  • Insulation resistance — Resolution: 0,1 M Ω
  • Insulation resistance — Accuracy: ±(4% +5 digits)
  • Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V
  • Insulation resistance — Measuring range: 600 … 6000 M Ω
  • Insulation resistance — Resolution: 1 M Ω
  • Insulation resistance — Accuracy: ±(5% +10 Digits)
  • Resistance — Measuring range: 0 … 600 Ω
  • Resistance — Resolution: 0,1 Ω
  • Resistance — Accuracy: ±(1.2% +10 Digits)
  • Resistance — Measuring range: 600 Ω … 6 kΩ
  • Resistance — Resolution: 0,001 kΩ
  • Resistance — Accuracy: ±(1.5 % +5 digits)
  • Resistance — Measuring range: 6 … 60 kΩ
  • Resistance — Resolution: 0,01 Ω
  • Resistance — Accuracy: ±(1.5 % +5 digits)
  • Resistance — Measuring range: 60 … 600 kΩ
  • Resistance — Resolution: 0,1 kΩ
  • Resistance — Accuracy: ±(1.5 % +5 digits)
  • Resistance — Measuring range: 600 kΩ … 6 M Ω
  • Resistance — Resolution: 0,001 M Ω
  • Resistance — Accuracy: ±(1.5 % +5 digits)
  • Resistance — Measuring range: 6 … 60 M Ω
  • Resistance — Resolution: 0,01 M Ω
  • Resistance — Accuracy: ±(2.5% +10 digits)
  • Frequency — Measuring range: 40 … 10000 Hz
  • Frequency — Resolution: 0,01 Hz
  • Frequency — Accuracy: ±(1% +5 digits)
  • General technical data — Measuring functions: MIN, MAX, HOLD, PI, DAR
  • General technical data — Display type: LC colour display
  • General technical data — Display size: 3,5 Inch
  • General technical data — Display refresh rate: 3 x per second
  • General technical data: Measuring rate 3 Hz
  • Storage medium Internal memory — Storage capacity: 1800 Values
  • Storage medium Internal memory — Storage interval from: 1 s
  • Storage medium Internal memory — Storage interval to: 60 min.
  • Storage medium Internal memory — Interface: Bluetooth
  • Storage medium Internal memory: Automatic power-off from…to 15 … 60 min.
  • Storage medium Internal memory: Safety standard CAT III 1000V, CAT IV 600V
  • Storage medium Internal memory: Diode test Test current: <1.5 mA
  • Storage medium Internal memory: Max. Voltage in open circuit: 3.2V DC
  • Storage medium Internal memory — Menu language: English, English (GB)
  • Storage medium Internal memory — Protection class (device): IP65
  • Storage medium Internal memory — (Rechargeable) battery: 6 x 1,5 V AA battery , Alkali-manganese
  • Storage medium Internal memory — Capacity: 2500 mAh
  • Storage medium Internal memory — Operating conditions: 5 … 40 °C , 0 … 80 % RH
  • Storage medium Internal memory — Storage conditions: -20 … 60 °C , 0 … 80 % RH
  • Storage medium Internal memory — Dimensions: ( L x W x H )215 x 100 x 65 mm
  • Storage medium Internal memory — Weight: 569 g

Delivery scope

  • 1 x Insulation Tester / Insulation Meter PCE-IT 110
  • 1 x Temperature probe type K
  • 2 x Set of test leads
  • 1 x Transport case
  • 6 x 1.5V AA batteries
  • 1 x Instruction manual You can find the “Meterbox Pro” app in the App Store