Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-HT 422 data logger for temperature and humidity

Data logger for temperature, relative humidity, CO2, TVOC and light intensity / 4GB memory / Power over Ethernet / MQTT / Email alarm / HTTP / FTP. The data logger for temperature and humidity is used to measure and store environmental data such as temperature, humidity, illuminance, CO2 content and TVOC concentration.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Andmemälu maht 4 GB
Eraldusvõime Süsinikdioksiid: 1 ppm, Süsinikdioksiid: 3 ppm, Süsinikdioksiid: 31 ppm, Süsinikdioksiid: 9 ppm, TVOC: 1 ppb, TVOC: 32 ppb, TVOC: 6 ppb
Weight (kg) 0.3
Kaitseklass IP20
Liides Ethernet, FTP, HTTP, Modbus RTU, Modbus TCP, MQTT, RS-485
Mõõtefunktsioonid Alarm
Mõõteintervall Reguleeritav diskreetimis- ja salvestuskiirus
Mõõdetav suurus Absoluutne niiskus, Kastepunkt, Suhteline õhuniiskus, Süsinikdioksiid, Temperatuur, TVOC, Valgustatus
Dimensions 120 x 80 x 25 mm
Toiteallikas Laetav aku, PoE
Power supply 6 V DC

Data logger for temperature, relative humidity, CO2, TVOC and light intensity / 4GB memory / Power over Ethernet / MQTT / Email alarm / HTTP / FTP

The data logger for temperature and humidity is used to measure and store environmental data such as temperature, humidity, illuminance, CO2 content and TVOC concentration. The data logger for temperature and humidity also calculates the dew point, absolute humidity and the water vapor content in the air. The data logger for temperature and humidity is used for stationary monitoring of laboratories, greenhouses, medicine and food stores, museums, etc. The data measured and calculated by the data logger for temperature and humidity are stored in the internal memory and can be called up via Ethernet and sent to the user. In addition to storing the measurement data, the data logger for temperature and humidity can send alarms by email or display them on a website. The data logger for temperature and humidity can be supplied via a power supply unit or autonomously via Power over Ethernet. An internal battery is built into the data logger for temperature and humidity to buffer the memory and the settings.

In addition to the built-in Ethernet interface, the data logger for temperature and humidity also has an RS485 interface available to the user. This can be addressed via Modbus RTU. The user can communicate with the data logger for temperature and humidity via Modbus TCP / IP, HTTP, FTP via the Ethernet interface. A web and FTP server as well as a DHCP and SMTP client complete the functionality of the data logger’s network interface.

Highlights

  • Temperature measuring range (-20 … +60 °C)
  • Relative humidity measuring range (0 … 95%)
  • CO2, TVOC and light measurement
  • Ethernet interface (PoE compatible)
  • Alarm (acoustic, email, visual)
  • 4 GB memory
  • Adjustable sampling / storage rate
  • FTP, HTTP server

Technical specifications

  • Measured variableAir humidity — Measuring range: 0 … 95% r.H.
  • Measured variableAir humidity — Accuracy: ± 3 % of reading (10 .. 90 %)
  • Measured variableAir humidity: ± 5 % of other
  • Measured variableAir humidity — Resolution: –
  • Measured variableTemperature — Measuring range: -20 … 60 °C
  • Measured variableTemperature — Accuracy: ± 0.6 °C (10 … 40 °C)
  • Measured variableTemperature: ± 1 °C of other
  • Measured variableTemperature — Resolution: –
  • Measured variableIlluminance — Measuring range: 0 … 60000 lx
  • Measured variableIlluminance — Accuracy: –
  • Measured variableIlluminance — Resolution: –
  • Measured variableTVOC — Measuring range: 0 … 60000 ppb
  • Measured variableTVOC — Accuracy: –
  • Measured variableTVOC — Resolution: 1 ppb (0 … 2008 ppb)
  • Measured variableTVOC: 6 ppb (… 11110 ppb)
  • Measured variableTVOC: 32 ppb (… 60000 ppb)
  • Measured variableCO2 — Measuring range: 400… 60000 ppm
  • Measured variableCO2 — Accuracy: –
  • Measured variableCO2 — Resolution: 1 ppm (400 ..1479ppm)
  • Measured variableCO2: 3 ppm (… 5144 ppm)
  • Measured variableCO2: 9 ( …17597 ppm)
  • Measured variableCO2: 31 ppm ( .. 60000 ppm)
  • saturated steam pressure, enthalpy — Interface: RS485 (Modbus RTU)
  • Ethernet Modbus TCP, HTTP, FTP, MQTT: Memory 4 GB
  • Ethernet Modbus TCP, HTTP, FTP, MQTT — Power supply: DC power pack 6 V / 1 A
  • Ethernet Modbus TCP, HTTP, FTP, MQTT: PoE IEEE 802.3af
  • Ethernet Modbus TCP, HTTP, FTP, MQTT — Power consumption: < 2 VA
  • Ethernet Modbus TCP, HTTP, FTP, MQTT: Warm-up time 15 minutes
  • Ethernet Modbus TCP, HTTP, FTP, MQTT — Operating conditions: -20 … 60°/ 95% r.H
  • Ethernet Modbus TCP, HTTP, FTP, MQTT: Degree of protection IP20
  • Wall mounting, sensor facing down — Dimensions: 120 x 80 x 25 mm
  • Wall mounting, sensor facing down — Weight: 300 g

Delivery scope

  • 1 x Data Logger for Temperature and Humidity PCE-HT 422
  • 1 x instruction manual Note: The power supply unit must be selected as an option!

Documents

FAQ