Digital Multimeter / automatic and manual measurement range selection / NCV and live test / true RMS and LoZ / min, max and hold functions / integrated LED torch
The Digital Multimeter is a multifunctional meter for the precise measurement of alternating and direct voltage as well as alternating current that can be measured without direct contact to the line. The Digital Multimeter is suitable for measuring resistance, temperature, diodes, continuity, frequencies and capacitance and is particularly useful for diagnosing electrical and electronic components.
For maximum measurement accuracy, the Digital Multimeter supports True RMS for non-sinusoidal waveforms and a Low Impedance (LoZ) function to reduce interference. The non-contact voltage test enables reliable detection of voltages in cables and sockets.
The 2-inch LC display ensures clear readability, even under poor lighting conditions and an integrated LED torch makes it easier to work in dark environments. The device also offers automatic and manual measurement range selection, allowing it to be flexibly adapted to different measuring situations. Other functions include overload protection, data hold, min, max and an automatic power-off after 15 minutes to conserve battery life. The power-off can also be deactivated for longer measurements.
Compact and easy to use, the Digital Multimeter is ideal for electrical installations, maintenance work and use in automation technology. It enables safe and efficient measurements, often without direct intervention in the circuit.
Highlights
- display range: 6000 counts
- measurement range selection: automatic and manual
- min, max and hold function
- 2-inch LC display
- integrated LED torch
- automatic power-off
Technical specifications
- Direct voltage DC — Measuring range: 0,1 … 600 mV
- Direct voltage DC — Resolution: 0,1 mV
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +5 digits)
- Direct voltage DC: Overload 1000 V
- Direct voltage DC — Measuring range: 600 mV … 6 V
- Direct voltage DC — Resolution: 0,001 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +5 digits)
- Direct voltage DC — Measuring range: 6 … 60 V
- Direct voltage DC — Resolution: 0,01 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +5 digits)
- Direct voltage DC — Measuring range: 60 … 600 V
- Direct voltage DC — Resolution: 0,1 V
- Direct voltage DC — Accuracy: ±(0.5 % of Rd +5 digits)
- Direct voltage DC — Measuring range: 600 … 1000 V
- Direct voltage DC — Resolution: 1 V
- Direct voltage DC — Accuracy: ±(0.8 % of Rd +5 digits)
- Capacity — Measuring range: 1 … 10 nF
- Capacity — Resolution: 0,001 nF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 10 … 100 nF
- Capacity — Resolution: 0,001 nF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 100 … 1000 nF
- Capacity — Resolution: 0,01 nF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 1000 nF … 10 µF
- Capacity — Resolution: 0,1 nF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 10 … 100 µF
- Capacity — Resolution: 0,001 µF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 100 … 1000 µF
- Capacity — Resolution: 0,01 µF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 1000 µF … 10 mF
- Capacity — Resolution: 0,1 µF
- Capacity — Accuracy: ±(4.0 % of Rd +5 digits)
- Capacity — Measuring range: 10 … 100 mF
- Capacity — Resolution: 0,001 mF
- Capacity — Accuracy: ±(5.0 % of Rd +10 digits)
- AC voltage — Measuring range: 0,1 … 600 mV
- AC voltage — Resolution: 0,1 mV
- AC voltage — Accuracy: ±(0.8 % of Rd +5 digits)
- AC voltage: Overload 750 V
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 600 mV … 6 V
- AC voltage — Resolution: 0,1 mV
- AC voltage — Accuracy: ±(0.8 % of Rd +5 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 6 … 60 V
- AC voltage — Resolution: 0,001 V
- AC voltage — Accuracy: ±(0.8 % of Rd +5 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 60 … 600 V
- AC voltage — Resolution: 0,01 V
- AC voltage — Accuracy: ±(0.8 % of Rd +5 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- AC voltage — Measuring range: 600 … 750 V
- AC voltage — Resolution: 0,1 V
- AC voltage — Accuracy: ±(1.0 % of Rd +5 digits)
- AC voltage — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 0,1 … 60 A
- Alternating current AC — Resolution: 0,01 A
- Alternating current AC — Accuracy: ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits)
- Alternating current AC — Frequency: range 40 … 400 Hz
- Alternating current AC — Measuring range: 60 … 600 A
- Alternating current AC — Resolution: 0,1 A
- Alternating current AC — Accuracy: ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits)
- Alternating current AC — Frequency: range 40 … 400 Hz
- Alternating current AC — Measuring range: 600 … 1000 A
- Alternating current AC — Resolution: 1 A
- Alternating current AC — Accuracy: ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits)
- Alternating current AC — Frequency: range 40 … 60 Hz
- Resistance — Measuring range: 0,1 … 600 Ω
- Resistance — Resolution: 1 Ω
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Resistance — Measuring range: 600 Ω … 6 kΩ
- Resistance — Resolution: 1 Ω
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Resistance — Measuring range: 6 … 60 kΩ
- Resistance — Resolution: 0,001 kΩ
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Resistance — Measuring range: 60 … 600 kΩ
- Resistance — Resolution: 0,01 kΩ
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Resistance — Measuring range: 600 kΩ … 6 M Ω
- Resistance — Resolution: 0,1 kΩ
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Resistance — Measuring range: 6 … 60 M Ω
- Resistance — Resolution: 0,001 M Ω
- Resistance — Accuracy: ±(1.0 % of Rd +5 digits)
- Frequency — Measuring range: 0 … 10 Hz
- Frequency — Resolution: 0,001 Hz
- Frequency — Accuracy: ±(1.0 % of Rd +3 digits)
- Frequency — Measuring range: 10 … 100 Hz
- Frequency — Resolution: 0,001 Hz
- Frequency — Accuracy: ±(1.0 % of Rd +3 digits)
- Frequency — Measuring range: 100 … 1000 Hz
- Frequency — Resolution: 0,01 Hz
- Frequency — Accuracy: ±(1.0 % of Rd +3 digits)
- Frequency — Measuring range: 1000 Hz … 10 kHz
- Frequency — Resolution: 0,1 Hz
- Frequency — Accuracy: ±(1.0 % of Rd +3 digits)
- Frequency — Measuring range: 10 … 100 kHz
- Frequency — Resolution: 0,001 kHz
- Frequency — Accuracy: ±(1.0 % of Rd +3 digits)
- Frequency — Measuring range: 100 … 1000 kHz
- Frequency — Resolution: 0,01 kHz
- Frequency — Accuracy: ±(1,0 % v.Mw. +3 Digits)
- Frequency — Measuring range: 1000 kHz … 10 MHz
- Frequency — Resolution: 0,1 kHz
- Frequency — Accuracy: ±(3.0% v.Mw. +3 Digits)
- Temperature — Measuring range: -20 … 0 °C
- Temperature — Resolution: 0,1 °C
- Temperature — Accuracy: ±3°C
- Temperature — Measuring range: 0 … 400 °C
- Temperature — Resolution: 0,1 °C
- Temperature — Accuracy: ±1.0 % or ±2 °C
- Temperature — Measuring range: 400 … 1000 °C
- Temperature — Resolution: 0,1 °C
- Temperature — Accuracy: ±2.0 %
- Temperature — Measuring range: -4 … +32 °F
- Temperature — Resolution: 1 °F
- Temperature — Accuracy: ±6 °F
- Temperature — Measuring range: 32 … 752 °F
- Temperature — Resolution: 1 °F
- Temperature — Accuracy: ±1.0 % or ±4 °F
- Temperature — Measuring range: 752 … 1832 °F
- Temperature — Resolution: 1 °F
- Temperature — Accuracy: ±2.0 %
- General technical data — Measuring functions: MIN, MAX, HOLD
- General technical data — Display type: LCD
- General technical data — Display size: 2 Inch
- General technical data: Standard(s)IEC61010-1, IEC 61010-2-032, IEC 61010-2-033
- General technical data: Maximum cable diameter 35 mm
- General technical data: Automatic power-off 15 min
- General technical data: Safety standard CAT III 1000V, CAT IV 600V
- General technical data: max. input impedance 10 M Ω
- General technical data — Measuring range: selection Automatic, Manual
- General technical data: Diode test Test current: approx. 1.5 mA
- General technical data: Test voltage: approx. 1 V
- General technical data: Overload protection: 250 V
- General technical data: Display range 6000 counts
- General technical data — Protection class (device): IP20
- General technical data — (Rechargeable) battery: 3 x 1,5 V AAA battery , Alkali-manganese
- General technical data — Capacity: 1200 mAh
- General technical data — Operating conditions: 0 … 40 °C , 0 … 80 % RH
- General technical data — Storage conditions: -10 … 60 °C , 0 … 70 % RH
- General technical data — Dimensions: ( L x W x H )240 x 85 x 45 mm
- General technical data — Weight: 327 g
Delivery scope
- 1 x Digital Multimeter PCE-CM 6
- 1 x set of test leads
- 1 x K-type thermocouple
- 3 x 1.5 V AAA battery
- 1 x carrying case
- 1 x user manual