PCE-PA 8000 Portable Power Analyzer Real-time current, voltage and power consumption measurement / Built-in data recorder with adjustable rate / Includes current clamps, alligator clips, test leads, SD card memory and 2-year warranty against manufacturer defects
PCE-PA 8000 is a portable handheld Portable Power Analyzer used for the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This handy power quality analyzer not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.
The PCE-PA 8000 Portable Power Analyzer provides true RMS measurements of current and voltage. The Portable Power Analyzer also determines power factor (PF), phase angle (Φ), active power, apparent power and reactive power. The three current clamps included with the Portable Power Analyzer can be used on wires and cables with a diameter of 2.0″ / 50 mm, allowing for use with the power grid. Also included in the delivery contents are four alligator clips, four test leads and an SD card. For real-time current, voltage and power consumption measurements at a glance, the PCE-PA 8000 features an easy-to-read 3.7″ / 94 mm (320 x 240 pixel) LCD screen with backlight.
Highlights
- Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1
- phase / 2 conductors, 1 phase / 3 conductors
- Measures effective real value of current and voltage
- Measures active, apparent, and reactive power
- Power Factor (PF), phase angle (Φ)
- Measures voltage up to 600 V
- Measures current up to 1200 A
- It meets the IEC 1010 and CAT III 600 V standards
- Integrated timer and calendar to record data
- Measured values are recorded in the included SD card
- Data is stored in Excel format for further study
- Data can be transferred to a PC through data cable
- Large 3.7 in / 94 mm LCD display
Technical specifications
- AC voltage — Measuring range: 10 … 600 V
- AC voltage — Resolution: 0,1 V
- AC voltage — Accuracy: ±(0.5 % +0.5 V)
- AC voltage: Overload 720 V RMS
- Alternating current AC — Measuring range: 0,2 … 10 A
- Alternating current AC — Resolution: 0,001 A
- Alternating current AC — Accuracy: ±(0.5 % +1 A)
- Alternating current AC: Overload 1300 A with current clamp
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 10 … 20 A
- Alternating current AC — Resolution: 0,01 A
- Alternating current AC — Accuracy: ±(0.5 % +1 A)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 0,2 … 100 A
- Alternating current AC — Resolution: 0,01 A
- Alternating current AC — Accuracy: ±(0.5 % +5 A)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 100 … 200 A
- Alternating current AC — Resolution: 0,1 mA
- Alternating current AC — Accuracy: ±(0.5 % +5 A)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 0,2 … 1000 A
- Alternating current AC — Resolution: 0,1 mA
- Alternating current AC — Accuracy: ±(0.5 % +5 A)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Alternating current AC — Measuring range: 1000 … 1200 A
- Alternating current AC — Resolution: 1 A
- Alternating current AC — Accuracy: ±(0.5% +5 A)
- Alternating current AC — Frequency: range 40 … 1000 Hz
- Active power — Measuring range: 0 … 9,999 kW
- Active power — Resolution: 0,001 kW
- Active power — Accuracy: ±(1 % +0.008 kW)
- Active power — Measurement range: up to 10 kW
- Active power — Measurement range: from 99,99 kW
- Active power — Resolution: 0,01 kW
- Active power — Accuracy: ±(1% +0.08 kW)
- Active power — Measuring range: 100 … 999,9 kW
- Active power — Resolution: 0,1 kW
- Active power — Accuracy: ±(1% +0.8 kW)
- Active power — Measuring range: 1 … 9,999 MW
- Active power — Resolution: 0,001 MW
- Active power — Accuracy: ±(1 % +0.008 MW)
- Reactive power — Measuring range: 0 … 9,99 kVAR
- Reactive power — Resolution: 0,001 kVAR
- Reactive power — Accuracy: ±(1 % +0.008 kVAR)
- Reactive power — Measuring range: 10 … 99,9 kVAR
- Reactive power — Resolution: 0,01 kVAR
- Reactive power — Accuracy: ±(1 % +0.08 kVAR)
- Reactive power — Measuring range: 100 … 999,9 kVAR
- Reactive power — Resolution: 0,1 kVAR
- Reactive power — Accuracy: ±(1 % +0.8 kVAR)
- Reactive power — Measuring range: 1 … 9,9 MVAR
- Reactive power — Resolution: 0,001 MVAR
- Reactive power — Accuracy: ±(1% +0.008 MVAR)
- Phase angle — Measuring range: -180 … +180 °
- Phase angle — Resolution: 0,1 °
- Phase angle — Accuracy: ±1 °
- Apparent power — Measuring range: 0 … 9,9 kVA
- Apparent power — Resolution: 0,001 kVA
- Apparent power — Accuracy: ±(1% +0.008 kVA)
- Apparent power — Measuring range: 10 … 99,99 kVA
- Apparent power — Resolution: 0,01 kVA
- Apparent power — Accuracy: ±(1% +0.08 kVA)
- Apparent power — Measuring range: 100 … 999,9 kVA
- Apparent power — Resolution: 0,1 kVA
- Apparent power — Accuracy: ±(1 % +0.8 kVA)
- Apparent power — Measuring range: 1 … 9,99 MVA
- Apparent power — Resolution: 0,001 MVA
- Apparent power — Accuracy: ±(1 % +0,008 MVA)
- Power factor — Measuring range: 0 … 1
- Power factor — Resolution: 0.01
- Power factor — Accuracy: ±0.04
- Active energy — Measuring range: 0 … 9,9 kWh
- Active energy — Resolution: 0,001 kWh
- Active energy — Accuracy: ±(1% +0.008 kWh)
- Active energy — Measuring range: 10 … 99,9 kWh
- Active energy — Resolution: 0,01 kWh
- Active energy — Accuracy: ±(1% +0.08 kWh)
- Active energy — Measuring range: 100 … 999,9 kWh
- Active energy — Resolution: 0,1 kWh
- Active energy — Accuracy: ±(1% +0.8 kWh)
- Active energy — Measuring range: 1 … 9,99 MWh
- Active energy — Resolution: 0,001 MWh
- Active energy — Accuracy: ±(1% +0.008 MWh)
- Apparent energy — Measuring range: 0 … 9,9 kVAh
- Apparent energy — Resolution: 0,001 kVAh
- Apparent energy — Accuracy: ±(1 % +0.008 kVAh)
- Apparent energy — Measuring range: 10 … 99,9 kVAh
- Apparent energy — Resolution: 0,01 kVAh
- Apparent energy — Accuracy: ±(1% +0.08 kVAh)
- Apparent energy — Measuring range: 100 … 999,9 kVAh
- Apparent energy — Resolution: 0,1 kVAh
- Apparent energy — Accuracy: ±(1% +0.8 kVAh)
- Apparent energy — Measuring range: 1 … 9,9 MVAh
- Apparent energy — Resolution: 0,001 MVAh
- Apparent energy — Accuracy: ±(1% +0,008 KVAH)
- Reactive energy — Measuring range: 0 … 9,9 kVArh
- Reactive energy — Resolution: 0,001 kVArh
- Reactive energy — Accuracy: ±(1% +0.008 KVARh)
- Reactive energy — Measuring range: 10 … 99,9 kVArh
- Reactive energy — Resolution: 0,01 kVArh
- Reactive energy — Accuracy: ± (1% + 0.08 KVARh)
- Reactive energy — Measuring range: 100 … 999,9 kVArh
- Reactive energy — Resolution: 0,1 kVArh
- Reactive energy — Accuracy: ±(1% +0.8 KVARh)
- Reactive energy — Measuring range: 1 … 9,99 MVARh
- Reactive energy — Resolution: 0,001 MVARh
- Reactive energy — Accuracy: ±(1% +0.008 KVARH)
- Frequency — Measuring range: 45 … 65 Hz
- Frequency — Resolution: 0,1 Hz
- Frequency — Accuracy: 0.1 Hz
- General technical data — Measuring functions: HOLD
- General technical data — Display type: LCD with backlight
- General technical data — Display size: 3,7 Inch
- Storage medium SD card — Storage capacity: 2 GB
- Storage medium SD card — Storage interval from: 2 s
- Storage medium SD card — Storage interval to: 120 min.
- Storage medium SD card — Interface: USB, RS232
- Storage medium SD card: Standard(s)IEC 1010
- Storage medium SD card: Current consumption meter 300 mA DC
- Storage medium SD card: Current consumption current clamp 34 mA DC
- Storage medium SD card: Maximum cable diameter 50 mm
- Storage medium SD card: Safety standard CAT III 600V
- Storage medium SD card: Overload protection Voltage AC 720 V / current AC 1300 A
- Storage medium SD card — Dimensions: Current clamp: 210 x 85 x 33 mm
- Storage medium SD card — Measuring range: selection Automatic, Manual
- Storage medium SD card — Menu language: English, English (GB)
- Storage medium SD card — Protection class (device): IP21
- Storage medium SD card — Power supply: 9V
- Connector type Device-europlug — (Rechargeable) battery: 8 x 1,5 V AA battery , Alkali-manganese
- Connector type Device-europlug — Capacity: 3000 mAh
- Connector type Device-europlug — Operating conditions: 0 … 50 °C , 0 … 80 % RH
- Connector type Device-europlug — Storage conditions: 0 … 50 °C , 0 … 80 % RH
- Connector type Device-europlug — Dimensions: ( L x W x H )225 x 125 x 64 mm
- Connector type Device-europlug — Weight: 811,5 g
Delivery scope
- 1 x PCE-PA 8000 Portable Power Analyzer
- 3 x Current clamps
- 4 x Test cables
- 4 x Alligator clips
- 1 x 2 GB SD card
- 1 x 9 V DC mains component
- 8 x Batteries 1.5 V AA
- 1 x Carrying case