Power Meter PCE-GPA 62 with network analyzer / Power and energy meter (real time) with data logger, graphic display, interface for PC and software
The One-Phase Digital Multimeter (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The Three-Phase Digital Multimeter PCE-GPA 62 comes with a built-in graphic display to show network analyzer values. Measured values can be both recorded and transferred to a PC for further analysis.
The One-Phase Digital Multimeter PCE-GPA 62 is a professional handheld device to determine several parameters. Thanks to the backlight display, it is possible to get an accurate reading of measured values even with poor light conditions. Although the Three-Phase Digital Multimeter PCE-GPA 62 comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when an annual recalibration is required.
Highlights
- Real-time test, register and measurement of voltage and current (real
- effective)
- Measures power factor and phase angle, frequency, energy, active, reactive
- and apparent power (single-
- phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Graphic display
- Auto shut-off after 15 min. (this function may be disabled)
- Optional ISO calibration
Technical specifications
- AC voltage — Measuring range: 4 … 600 V
- AC voltage — Resolution: 0,1 V
- AC voltage — Accuracy: ±0.5 % ±5 digits
- AC voltage: Overload 800V
- AC voltage — Frequency: range 50 … 60 Hz
- Alternating current AC — Measuring range: 4 … 1500 A
- Alternating current AC — Resolution: 0,1 A
- Alternating current AC — Accuracy: ±1% ±5 digits
- Alternating current AC: Overload 2000 A
- Alternating current AC — Frequency: range 50 … 60 Hz
- Active power — Measuring range: 10 … 999,9 W
- Active power — Resolution: 0,1 W
- Active power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Active power — Measurement range: up to 1 kW
- Active power — Measurement range: from 9,999 kW
- Active power — Resolution: 0,001 kW
- Active power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A) W
- Active power — Measuring range: 10 … 99,99 kW
- Active power — Resolution: 0,01 kW
- Active power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Active power — Measuring range: 100 … 999,9 kW
- Active power — Resolution: 0,1 kW
- Active power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Active power — Measuring range: 1000 … 9999 kW
- Active power — Resolution: 1 kW
- Active power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Reactive power — Measuring range: 10 … 999,9 VAR
- Reactive power — Resolution: 0,1 VAR
- Reactive power — Accuracy: ±2% ±30 digits (>20V and >20 A) / ±3% ±40 digits (<20V <20 A)
- Reactive power — Measuring range: 1 … 9,999 kVAR
- Reactive power — Resolution: 0,001 kVAR
- Reactive power — Accuracy: ±2% ±30 digits (>20V and >20 A) / ±3% ±40 digits (<20V <20 A)
- Reactive power — Measuring range: 10 … 99,99 kVAR
- Reactive power — Resolution: 0,01 kVAR
- Reactive power — Accuracy: ±2% ±30 digits (>20V and >20 A) / ±3% ±40 digits (<20V <20 A)
- Reactive power — Measuring range: 100 … 999,9 kVAR
- Reactive power — Resolution: 0,1 kVAR
- Reactive power — Accuracy: ±2% ±30 digits (>20V and >20 A) / ±3% ±40 digits (<20V <20 A)
- Reactive power — Measuring range: 1000 … 9999 kVAR
- Reactive power — Resolution: 1 kVAR
- Reactive power — Accuracy: ±2% ±30 digits (>20V and >20 A) / ±3% ±40 digits (<20V <20 A)
- Phase angle — Measuring range: -180 … +180 °
- Phase angle — Resolution: 0,1 °
- Phase angle — Accuracy: ±1 °
- Phase angle — Measuring range: 0 … 360 °
- Phase angle — Resolution: 0,1 °
- Phase angle — Accuracy: ±1°
- Apparent power — Measuring range: 10 … 999,9 VA
- Apparent power — Resolution: 0,1 VA
- Apparent power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Apparent power — Measuring range: 1 … 9,999 kVA
- Apparent power — Resolution: 0,001 kVA
- Apparent power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Apparent power — Measuring range: 10 … 99,99 kVA
- Apparent power — Resolution: 0,01 kVA
- Apparent power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Apparent power — Measuring range: 100 … 999,9 kVA
- Apparent power — Resolution: 0,1 kVA
- Apparent power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Apparent power — Measuring range: 1000 … 9999 kVA
- Apparent power — Resolution: 1 kVA
- Apparent power — Accuracy: ±1% ±20 digits (>20V and >20 A) / ±2% ±40 digits (<20V <20 A)
- Power factor — Measuring range: 0 … 1
- Power factor — Resolution: 0.001
- Power factor — Accuracy: ±0.04 (>20 V and >20 A) / ±0.1 (<20 V and <20 A)
- Active energy — Measuring range: 0 Wh … 999,999 kVArh
- Active energy — Resolution: 20 Digits
- Active energy — Accuracy: ±1% of Rd
- Apparent energy — Measuring range: 0 VAh … 999,999 kVAh
- Apparent energy — Resolution: 20 Digits
- Apparent energy — Accuracy: ±1% of Rd
- Reactive energy — Measuring range: 0 varh … 999,999 kVArh
- Reactive energy — Resolution: 20 Digits
- Reactive energy — Accuracy: ±1% of Rd
- Frequency — Measuring range: 46 … 65 Hz
- Frequency — Resolution: 0,1 Hz
- Frequency — Accuracy: ±0.3 Hz
- Harmonic measurement (harmonics) — Measuring range: 1 … 50 (ordinal number)
- General technical data — Measuring functions: HOLD
- General technical data — Frequency: 50 … 60 Hz
- General technical data — Display type: LCD graphic display with backlight
- General technical data — Display size: 2 Inch
- Storage medium Internal memory — Storage capacity: 50000 Data records
- Storage medium Internal memory — Interface: USB
- Storage medium Internal memory: Standard(s)EN 61010-2-032
- Storage medium Internal memory: Maximum cable diameter 55 mm
- Storage medium Internal memory: Automatic power-off 15 min
- Storage medium Internal memory: Safety standard CAT III 600V
- Storage medium Internal memory — Dimensions: Current clamp opening: max. 55 mm
- Storage medium Internal memory — Measuring range: selection Automatic
- Storage medium Internal memory — Menu language: English, English (GB)
- Storage medium Internal memory — Protection class (device): IP20
- Storage medium Internal memory — (Rechargeable) battery: 2 x 1,5 V AA battery , Alkali-manganese
- Storage medium Internal memory — Capacity: 3000 mAh
- Storage medium Internal memory — Operating conditions: -10 … 50 °C , 0 … 85 % RH
- Storage medium Internal memory — Storage conditions: -10 … 50 °C , 0 … 85 % RH
- Storage medium Internal memory — Dimensions: ( L x W x H )271 x 112 x 46 mm
- Storage medium Internal memory — Weight: 650 g
Delivery scope
- 1 x Three-Phase Power Meter PCE-GPA 62
- 2 x Isolated measuring pins with 2 m / 6.6 ft of cable each
- 2 x Batteries
- 1 x Carrying case
- 1 x USB cable for a PC
- 1 x Software (in English)
- 1 x User’s manual
