Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-EMF 40 emf measuring device

Categories:

EMF measuring device PCE-EMF 40 Gauss meter with 2.4'' display / Background lighting adjustable in four levels / Measuring range up to 2000V / m / 3-axis measurement / For mobile and fast use. With this gauss meter it is possible to measure magnetic fields up to 2000 mG directly.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Ekraan LCD
Eraldusvõime Magnetvälja tugevus: 0,01 mA/m, Magnetvälja tugevus: 0,01 mV/m, Magnetvälja tugevus: 0,01 µT, Magnetvälja tugevus: 0,01 µW/cm², Magnetvälja tugevus: 0,1 mG, Magnetvälja tugevus: 0,1 µW/m², Magnetvälja tugevus: 1 V/m
Weight (kg) 0.1
Kaitseklass IP20
Mõõtefunktsioonid Alarm, Automaatne väljalülitus, Maksimaalväärtus, Minimaalväärtus, Mõõtühiku valik, Näidu hoidmine
Mõõteintervall 1 Hz
Mõõdetav suurus Magnetvälja tugevus
Dimensions 107 x 60 x 25 mm
Toiteallikas Patarei
Töötingimused (% RH) 0 - 80
Töötingimused (°C) 0 - 50

EMF measuring device PCE-EMF 40 Gauss meter with 2.4” display / Background lighting adjustable in four levels / Measuring range up to 2000V / m / 3-axis measurement / For mobile and fast use

With this gauss meter it is possible to measure magnetic fields up to 2000 mG directly. At the same time, the gauss meter shows the strength of the magnetic field numerically using an X, Y and Z axis. Another measuring function of the gauss meter is the electromagnetic field strength measurement. With this measuring function in the gauss meter, the electromagnetic field strength on supply lines can be determined at a frequency of 50/60 Hz. It is also possible to carry out measurements in the high frequency range with the gauss meter. Thus, measurements can be carried out with the gauss meter on, for example, a WLAN router or a mobile phone. Because of its many measuring functions, the gauss meter is a compact and multifunctional measuring device.

In addition to the numerical display on the gauss meter, a graphical progression of the last 20 measured values ​​is also displayed. The measured value is also displayed as a bar diagram by the gauss meter. This bar chart on the gauss meter is divided into three traffic light colors. As soon as the measured value exceeds a fixed value, so that the bar chart on the gauss meter has reached the red area, an acoustic alarm is activated. This alarm on the gauss meter switches off automatically as soon as the measured value is below the fixed limit threshold.

All three measurement modes can be read off simultaneously on the 2.4” TFT display of the gauss meter. Switching between the individual measurement modes on the gauss meter is therefore not necessary. The background lighting of the gauss meter can be adjusted in 4 levels. Thus, the display of the gauss meter can be adapted to the most varied of environmental conditions at the touch of a button.

Highlights

  • Three different measuring function
  • Many different units can be set
  • Alarm when limit value is exceeded
  • Automatic shutdown
  • With three-axis measurement
  • For low frequencies and high frequencies

Technical specifications

  • Low-frequency magnetic field — Measuring range: 20 … 200 µT
  • Low-frequency magnetic field — Resolution: 0,01 µT
  • Low-frequency magnetic field — Accuracy: ±12% +5 digits
  • Low-frequency magnetic field: Bandwidth 50 … 60 Hz
  • Low-frequency magnetic field — Measuring range: 200 … 2000 mG
  • Low-frequency magnetic field — Resolution: 0,1 mG
  • Low-frequency magnetic field — Accuracy: ±12% +5 digits
  • Low-frequency magnetic field: Bandwidth 50 … 60 Hz
  • Low-frequency electromagnetic field — Measuring range: 50 … 2000 V/m
  • Low-frequency electromagnetic field — Resolution: 1 V/m
  • Low-frequency electromagnetic field — Accuracy: ±7% +20 Digits
  • Low-frequency electromagnetic field: Bandwidth 50 … 60 Hz
  • High-frequency electromagnetic field — Measuring range: 30 mV/m … 11 V/m
  • High-frequency electromagnetic field — Resolution: 0,01 mV/m
  • High-frequency electromagnetic field — Accuracy: 1.0 dB at 1 V/m and 900 MHz, >1 V/m for reference only
  • High-frequency electromagnetic field: Bandwidth 50 … 3500 MHz
  • High-frequency electromagnetic field — Measuring range: 0,02 … 32 µW/cm²
  • High-frequency electromagnetic field — Resolution: 0,01 µW/cm²
  • High-frequency electromagnetic field — Accuracy: 1.0 dB at 1 V/m and 900 MHz, >1 V/m for reference only
  • High-frequency electromagnetic field: Bandwidth 50 … 3500 MHz
  • High-frequency electromagnetic field — Measuring range: 2,3 µw/m² … 320,9 mW/m²
  • High-frequency electromagnetic field — Resolution: 0,1 µw/m²
  • High-frequency electromagnetic field — Accuracy: 1.0 dB at 1 V/m and 900 MHz, >1 V/m for reference only
  • High-frequency electromagnetic field: Bandwidth 50 … 3500 MHz
  • High-frequency electromagnetic field — Measuring range: 0,07 … 29,1 mA/m
  • High-frequency electromagnetic field — Resolution: 0,01 mA/m
  • High-frequency electromagnetic field — Accuracy: 1.0 dB at 1 V/m and 900 MHz, >1 V/m for reference only
  • High-frequency electromagnetic field: Bandwidth 50 … 3500 MHz
  • General technical data — Measuring functions: MIN, MAX, HOLD
  • General technical data — Display type: LCD with backlight
  • General technical data — Display size: 2,4 Inch
  • General technical data: Measuring rate 1 Hz
  • General technical data: Operating time 4,5 h
  • General technical data: Automatic power-off 10 min
  • Alarm Acoustic — Menu language: English, English (GB)
  • Alarm Acoustic — Protection class (device): IP20
  • Alarm Acoustic — (Rechargeable) battery: 3 x 1,5 V AAA battery , Alkali-manganese
  • Alarm Acoustic — Capacity: 1200 mAh
  • Alarm Acoustic — Operating conditions: 0 … 50 °C , 0 … 80 % RH
  • Alarm Acoustic — Storage conditions: 0 … 50 °C , 0 … 80 % RH
  • Alarm Acoustic — Dimensions: ( L x W x H )107 x 60 x 25 mm
  • Alarm Acoustic — Weight: 100 g

Delivery scope

  • 1 x EMF measuring device / EMF test device PCE-EMF 40
  • 3 x 1.5V AAA batteries
  • 1 x Instruction manual

Documents

FAQ