TTR 6600 Adsorption Dryer
Thanks to the heat recovery system integrated into the standard configuration and the electronic control of the dry air flow, the TTR 6600 —like the other TTR adsorption dryers—is one of a kind!
Its sturdy housing and the highest industry standards make the Trotec TTR 6600 a reliable partner for dehumidification, even under harsh conditions.
Advantages:
- High-quality equipment manufactured in Germany
- High moisture removal performance even at low temperatures
- Reliable silica gel sorption rotors with a washable and mechanically very stable design
- Integrated Heat Recovery
- Electric Regenerative Heating
A brief overview of the standard features of the TTR 6600:
- Steel body, galvanized and painted
- Flow Rate Control
- Weather Protection Design
- Millennium Management Module
- Rotor Rotation Control (Rotor and Drive)
- Over-temperature safety system with restart lock (regeneration air)
- Operating Temperature Control (Regeneration Air)
- Filter Monitoring (for each air stream and the common warning light)
- Dual-Valve Control *
- Configurable airflow direction adjustment (easy to change)
- External Connectors: In / Out
- Connection terminals for a hygrostat
- Potential-free contacts (operating, fault, filter)
TTR 6600 Technical Specifications:
- Drying capacity: 37.2 kg/h
- Dry air volume (nominal): 7,200 m³/h at 400 Pa
- Electrical connection: 3x 400 V / 50 Hz
- Regenerative air heating system: 45 kW
- Maximum power consumption: 50.5 kW
- Dimensions L x W x H: 1750 x 1100 x 1700 mm
- Weight: 720 kg
- Dry air inlet and outlet connections, Ø: 500/500 mm
- Connections for regeneration air inlet and outlet, Ø: 300/300 mm
Possible additional features:
- Stainless steel housing
- Humidity/Temperature Control
- Dew point sensor: -80 °C … +20 °C
- Using the Touchscreen Device
- GSM Remote Connection
- WLAN Remote Connection
- Heat Exchanger Module
- Steam Heater for Regenerative Air
- Gas-fired heating system for recirculated air
- Electric Heater for Dry Air
- HG 120 External Hygrostat
- HG 125 External Hygrostat
- Transport frame (stackable), with rollers
* With Duoventic, the output of each fan can be adjusted independently using a potentiometer; no throttling devices are needed on-site
| Dry air (inlet air at 20 °C / 60% RH) | ||
|---|---|---|
| Drying [kg/24h] | 892.8 | |
| Drying [kg/h] | 37.2 | |
| Free airflow [m³/h] | 7,200 | |
| Nominal Air Volume [m³/h] | 6,600 | |
| External pressure [Pa] | 400 | |
| Connection inlet diameter Ø [mm] | 500 | |
| Connection Outlet Ø [mm] | 500 | |
| Regenerative Air | ||
| Nominal Air Flow [m³/h] | 1330 | |
| External pressure [Pa] | 300 | |
| Connection Inlet Diameter Ø [mm] | 300 | |
| Connection Outlet Ø [mm] | 300 | |
| How It Works | ||
| Operating Principle | TTR-Trisorp-Dual | |
| Workspace | ||
| Minimum temperature [°C] | -20 | |
| Maximum temperature [°C] | 40 | |
| Humidity, min. [% RH] | 0 | |
| Maximum relative humidity [% RH (non-condensing)] | 100 | |
| Electrical Values | ||
| Power Connection | 380–480 V / 50–60 Hz | |
| Rated current consumption [A] | 73.5 | |
| Installed capacity [kW] | 50.5 | |
| Heating capacity [kW] | 45 | |
| Recommended protection [A] | 100 | |
| Electrical Connection | ||
| Terminal Connection | ||
| Automatic drying | ||
| Continuous drying | ||
| dimension | ||
| Length (without packaging) [mm] | 1,919 | |
| Width (without packaging) [mm] | 1,110 | |
| Height (without packaging) [mm] | 1680 | |
| weight | ||
| (without packaging) [kg] | 720 | |
| EQUIPMENT, FEATURES, AND FUNCTIONS | ||
|---|---|---|
| Housing Type | ||
| Steel body, galvanized and painted | ||
| plastic | – | |
| Metal-plastic composite housing | – | |
| Powder Coating | – | |
| stainless steel | available upon request | |
| Device Design | ||
| Indoor Installation (Standard) | ||
| Weather Protection | ||
| Rental Version | – | |
| stackable | – | |
| Interior Design | ||
| Wide selection | ||
| Rotor Rotation Control (Rotor and Drive) | ||
| Over-temperature safety system with restart lock (regeneration air) | ||
| Operating Temperature Control (Regeneration Air) | ||
| Filter Monitoring (for each air stream and the common warning light) | ||
| Dual-valve control | ||
| Configurable airflow direction adjustment (easy to change) | ||
| External ON/OFF terminals | ||
| Connection terminals for a hygrostat | ||
| Potential-free contacts (operational, fault, filter) | ||
| Hours Worked Counter | ||
| Airflow Control | ||
| integrated heat recovery | ||
| Sensor-Based Flowmatic Control | ||