Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

Commercial Adsorption Dryer TTR 800 86 l/24 h 950 m³/h 300 Pa

Commercial Adsorption Dryer TTR 800 86 l/24 h 950 m³/h 300 Pa

Thanks to the heat recovery system and electronic energy management integrated into its standard equipment, the Trotec TTR 800 —like other TTR adsorption dryers—is one of the most economical of its kind in the world!

  • In stock
12 546 price including km
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment

TTR 800 Commercial Adsorption Dryer

Powerful rotary dryer

Thanks to the heat recovery system and electronic energy management integrated into its standard equipment, the Trotec TTR 800 —like other TTR adsorption dryers—is one of the most energy-efficient units of its kind in the world!

A sturdy stainless steel housing and technology developed in accordance with the highest industry standards make the TTR 800 adsorption dryer a reliable partner for moisture removal.

Advantages of a dehumidifier:

  • Configurable airflow direction on all TTR models
  • Equipped with a variety of features and a wide range of equipment as standard
  • High cost-effectiveness, thanks to the modular component design
  • Thanks to the many optional accessories, the dryer can be customized for almost any application
  • Professional quality “made in Germany” — Original Troteci products
  • High moisture removal performance even at low temperatures
  • Sturdy stainless steel housing
  • Reliable silica gel sorption rotor
  • Configurable airflow direction adjustment (easy adjustment)
  • Dual-fan control – the performance of each fan can be adjusted separately using a potentiometer
  • The TTR Trisorp Dual principle, featuring separate air ducts for process and regeneration air, for pressure-neutral recirculation
  • Electric Regenerative Heating System
  • Filter Monitoring (Airflow and Collective Warning Light)
  • Thanks to its many configuration options, it can be customized for almost any application

TTR 800 Standard Features at a Glance:

  • Stainless steel housing
  • Rotor Rotation Control (Rotor and Drive)
  • Overheating protection system with a restart lock (regeneration air)
  • Operating Temperature Control (Regeneration Air)
  • Filter Monitoring (Airflow and Collective Warning Light)
  • Duoventic Control*
  • Configurable airflow direction adjustment (easy adjustment)
  • External On/Off Connection Terminals
  • Hygrostat connection terminals
item number TTR 800 TTR 1400 TTR 2000 TTR 2800 TTR 3700 TTR 5200 TTR 6600 TTR 8200 TTR 10000 TTR 12000 TTR 13500
Dry air (supply air at 20°C / 60% RH)
moisture removal [kg/24h] 86,.04 177,6 259,2 376,8 492 698,4 892,8 1108,8 1 322,40 1596 1790,4
moisture removal [kg/h] 3.,6 7.04 10.08 15.07 20.05 29.01.00 37.02.00 46.02.00 55.01.00 66.05.00 74.06.00
Free-flow air volume [m³/h] 950 1750 2350 3150 4300 5800 7200 9000 10 500 12 500 14 700
Nominal air flow rate [m³/h] 750 1450 2000 2800 3700 5200 6600 8200 9800 11 800 13 300
external pressure [Pa] 300 300 300 300 400 400 400 400 300 300 400
Connection Inlet Diameter Ø [mm] 250 250 315 315 315 500 500 500 700 700 700
Connection Port Ø [mm] 250 250 315 315 315 500 500 500 700 700 700
regeneration air
Nominal air flow rate [m³/h] 130 270 380 570 740 1050 1330 1660 1970 2380 2670
external pressure [Pa] 300 300 250 300 200 300 300 300 300 300 200
Connection Inlet Diameter Ø [mm] 160 160 200 200 200 300 300 300 400 400 400
Connection Port Ø [mm] 160 160 200 200 200 300 300 300 400 400 400
operating principle
operating principle TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual TTR Trisorp Dual
Workspace
Minimum temperature [°C] -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
Maximum temperature [°C] 40 40 40 40 40 40 40 40 40 40 40
Relative humidity min [%RH] 0 0 0 0 0 0 0 0 0 0 0
Maximum humidity [% RH (non-condensing)] 100 100 100 100 100 100 100 100 100 100 100
electrical values
power connection 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz 380–480 V/50–60 Hz
Rated current [A] 7.05 15 23 31.07.00 42.08.00 60 73.05.00 93,5 108 129 150
Installed capacity [kW] 4.09 9.08 15 21.06 28.08.00 40 50.05.00 64.05.00 74 89 103
Heating Capacity [kW] 4.01 9 12.05 18.09 24.05.00 36 45 57 66 81 90
Recommended protection [A] 16 16 32 32 63 63 100 125 160 160 250
electrical connection
terminal connection
automatic moisture removal
continuous moisture removal
dimension
Length (without packaging) [mm] 734 734 1,348 1,348 1,348 1919 1919 1919 2,032 2,032 2,032
Length including structure [mm]
Width (without packaging) [mm] 649 649 769 769 769 0,118055556 0,118055556 0,118055556 1460 1460 1460
Width including structure [mm]
Height (without packaging) [mm] 942 942 1,323 1,323 1,323 1680 1680 1680 1,802 1,802 1,802
Height including structure [mm]
Weight
(without packaging) [kg] 85 100 230 250 270 680 720 750 900 1000 1100
Operating Temperature Control (Regeneration Air)

Possible additional options:

  • Millennium Management Module
  • Flowmatic Volume Flow Control
  • Humidity/Temperature Control
  • Dew point sensor -80 °C … +20 °C
  • Touchscreen for device operation
  • GSM Remote Connection
  • Remote Connection via Wi-Fi
  • Heat Exchanger Module
  • Electric Fan Heater for Dry Air
  • HG 120 External Hygrostat
  • HG 125 External Hygrostat
  • Transport frame (stackable), with wheels

*With Duoventic, the power of each fan can be adjusted independently using a potentiometer; there is no need for gas levers on site

Dry air (supply air at 20°C / 60% RH)
Moisture removal [kg/24h] 86.4
Moisture removal [kg/h] 3.6
Free-flow air volume [m³/h] 950
Nominal Air Volume [m³/h] 750
External pressure [Pa] 300
Connection inlet diameter Ø [mm] 250
Connection port Ø [mm] 250
regeneration air
Nominal Air Flow Rate [m³/h] 130
External pressure [Pa] 300
Connection inlet diameter Ø [mm] 160
Connection port Ø [mm] 160
operating principle
Operating Principle TTR Trisorp Dual
Workspace
Minimum temperature [°C] -20
Maximum temperature [°C] 40
Minimum relative humidity [% RH] 0
Maximum humidity [% RH (non-condensing)] 100
electrical values
Power connection 380–480 V/50–60 Hz
Rated Current [A] 7.5
Installed capacity [kW] 4.9
Heating Capacity [kW] 4.1
Recommended protection [A] 16
electrical connection
terminal connection
automatic moisture removal
continuous moisture removal
dimension
Length (without packaging) [mm] 734
Width (without packaging) [mm] 649
Height (without packaging) [mm] 942
Weight
(without packaging) [kg] 85
EQUIPMENT, FEATURES, AND FUNCTIONS
Housing type
stainless steel
Rotor Rotation Control (Rotor and Drive)
Overheating protection system with a restart lock (regeneration air)
Operating Temperature Control (Regeneration Air)
Filter Monitoring (Airflow and Collective Warning Light)
Dual-valve control
Configurable airflow direction adjustment (easy adjustment)
Terminals for external ON/OFF control
Hygrostat connection terminals
Potential-free contacts (operating, fault, filter)
hour meter
airflow control
with integrated heat recovery

FAQ