PCE-HWA 30-ICA Thermal Anemometer with ISO Calibration Certificate
Thanks to its integrated data memory, the anemometer can store up to 960 measured values. The data can be read directly from the anemometer. At the same time, the anemometer’s measured values can be transferred to a computer via the micro-USB port. Software compatible with the anemometer is available on the PCE Instruments download portal for further data processing.
For optimal alignment, the anemometer’s telescoping shaft can be extended up to 750 mm. In addition, the anemometer’s head is semi-rigid, allowing it to be aligned in various ways. The anemometer’s 1000 mAh rechargeable battery enables mobile use. To charge the battery, connect the anemometer to a 5 V DC micro-USB power source.
features
– Software for reading measured values
– Rotatable telescopic arm
– Measurement range: 0.3 … 30.0 m/s
– Data storage for 960 measured values
– Beaufort scale
specification
| wind speed | m/s |
| Measurement range | 0.3 … 30.0 m/s |
| resolution | 0.01 m/s |
| Accuracy | ±3% ±0.1 m/s or Mw. |
| wind speed | feet/min |
| measurement range | 60 … 5,904 feet/min |
| resolution | 0.01, 0.1, 1 foot/min |
| Accuracy | ±3% ±20 feet/min or Mw. |
| wind speed | knots |
| Measurement range | 0.6 … 58.3 knots |
| resolution | 0.01 knots |
| Accuracy | ±3% ±0.2 knots or Mw. |
| wind speed | km/h |
| Measurement range | 1.0 … 108.0 km/h |
| resolution | 0.01 km/h |
| Accuracy | ±3% ±0.4 km/h or Mw. |
| wind speed | mph |
| Measurement range | 0.7 … 67 mph |
| resolution | 0.01 mph |
| Accuracy | ±3% ±0.2 mph v. Mw. |
| volumetric flow | CMM (m³/min) |
| Measuring range | 0 … 999,900 m³/min |
| resolution | 0.001 … 100 m³/min |
| Adjustable area | 0.001 … 999 m² |
| volume flow | CFM (FT³/min) |
| Measurement range | 0 … 999,900 ft³/min |
| resolution | 0.001 … 100 m³/min |
| Adjustable area | 0.001 … 999 m³ |
| Temperature measurement | °C |
| Measurement range | 0…45 °C |
| resolution | 0.1 °C |
| accuracy | ±1.0 °C |
| Temperature Measurement | °F |
| measurement range | 32 … 113 °F |
| resolution | 0.18 °F |
| accuracy | ±1.8 °F |
| Additional Specifications | |
| probe length | 270 … 990 mm |
| probe diameter | Ø0.8 … 1.2 mm |
| interface | micro-USB |
| Data Storage | 960 measured values |
| power source | 3.7 V, 1000 mAh battery |
| 5 V DC, 1 A micro-USB port | |
| Power consumption | 15 … 35 mA without backlight |
| 70 … 100 mA with backlight | |
| battery low indicator | <3.4 V |
| Operating conditions | 0 … 50 °C, 40 … 80 % relative humidity, non-condensing |
| Storage conditions | -20 … 60 °C, < 80% relative humidity, non-condensing |
| Dimensions | 70 x 194 x 35 mm |
| Weight | 400 g |
scope of delivery
1 x Micro USB cable
1 x Carrying case
1 x User Manual
1 x ISO calibration certificate