Data Logger / Data Logging Instrument / Measurement of beta, gamma and X-rays / Adjustable limit values / Progression diagram / Minimum, maximum and average values / Internal memory with PC transfer via software
The Data Logger / Data Logging Instrument is a portable device mainly used for monitoring X, γ and β radiation. The Data Logger / Data Logging Instrument is equipped with a glass Geiger-Müller counter tube (GM tube), which is known for its high measurement accuracy and sensitivity, and has a 2.4-inch TFT LCD display.
The Data Logger / Data Logging Instrument offers audible, visual and vibration alarms with customizable dose rate and total dose limits. It enables simultaneous real-time measurement of the dose rate and recording of the cumulative dose over a set period of time. In addition, the device displays the minimum, maximum and average values of the measurements.
The supplied software enables live measurement and data transfer from the internal memory. Thanks to its compact design, energy efficiency and versatility, the Data Logger / Data Logging Instrument is ideal for both professional and private use.
Highlights
- Real-time value, average value, total dose
- Sensitivity: 1 cps/μSv/h (related to Co-60)
- Adjustable alarm limit for total dose
- Adjustable time dose
- Long-term measurements
- Radiation events in CPS and CPM
- Data memory and software
- Mounting clip
Technical specifications
- Measurement type Real-time value — Measuring range: 0,01 µSv/h … 50 mSv/h
- Measurement type Real-time value — Resolution: 0,01 µSv/h
- Measurement type Real-time value — Accuracy: <10 % at 1 mSv/h
- Measurement type Total dose — Measuring range: 0 µSv … 1000 Sv
- Measurement type Total dose — Resolution: 0,01 µSv
- Measurement type Total dose — Accuracy: <10 % at 1 mSv/h
- General technical data — Measuring functions: MIN, MAX, Average value
- Types of radiation Beta radiation, Gamma rays, X-rays: Energy range 48 … 1500 keV
- Types of radiation Beta radiation, Gamma rays, X-rays — Display type: LCD
- Types of radiation Beta radiation, Gamma rays, X-rays — Display size: 2,4 Inch
- Storage medium Internal memory — Storage capacity: 10000 Values
- Storage medium Internal memory — Interface: USB-C
- Storage medium Internal memory — Sensor: Geiger-Müller counter tube (glass)
- Storage medium Internal memory: Operating time 30 Day(s)
- Alarm optical, Acoustic, Vibration: Alarm modes Setting range for the dose rate: 0 … 9.99 µSv/h
- Alarm optical, Acoustic, Vibration: Setting range for total dose: 0 … 9999 µSv
- Alarm optical, Acoustic, Vibration: Sensitivity 1 cps/μSv/h (related to Co-60)
- Alarm optical, Acoustic, Vibration — Menu language: English, Chinese, English (GB)
- Alarm optical, Acoustic, Vibration — Protection class (device): IP52
- Alarm optical, Acoustic, Vibration — Power supply: 5V DC
- Alarm optical, Acoustic, Vibration — (Rechargeable) battery: 1 x 3,7 V internal , Lithium polymer battery
- Alarm optical, Acoustic, Vibration — Capacity: 1800 mAh
- Alarm optical, Acoustic, Vibration — Operating conditions: -10 … 45 °C , 0 … 95 % RH
- Alarm optical, Acoustic, Vibration — Storage conditions: -10 … 45 °C , 0 … 80 % RH
- Alarm optical, Acoustic, Vibration — Dimensions: ( L x W x H )127 x 65 x 32 mm
- Alarm optical, Acoustic, Vibration — Weight: 160 g
Delivery scope
- 1 x PCE-RDM 15 Data Logger / Data Logging Instrument
- 1 x USB-C cable
- 1 x Operating manual