PCE-830-1 Portable Power Analyzer with 3 phases / Measures power and analyses harmonics / Includes memory, interface, and software
The PCE-830 Portable Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Portable Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Portable Power Analyzer. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductors) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 Portable Power Analyzer the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the included analysis software. The device comes with everything needed to be measuring and analysing from the moment it arrives. Although the Portable Power Analyzer comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when a recalibration is required.
Highlights
- Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1
- phase / 2 conductors, 1 phase / 3 conductors
- Measures effective real value (V 123 and I 123)
- Measures active power (W, KW, MW, GW)
- Measures apparent and reactive power (KVA, KVAR)
- Power Factor (PF), phase angle (Φ)
- Measures energy and work (Wh, KWh, KVARh, PFh)
- Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a
- factory to be determined
- Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4
- conductors])
- CT conditions (1 to 600) and PT (1 to 3000) are programmable
- Indicates current wave forms and voltage overlap.
- 512 KB of memory with programmable intervals to save data every 2 to 3000
- seconds, 17,470 readings using the system of 3 phases / 4 conductors
- Indicates wave forms, efficiency parameters, and harmonic distortion
- Backlit LCD with dot matrix
- Average power (AD in W, KW, MW)
- Maximum power (MD in W, KW, MW) with the programmable period
- Analysis of harmonic distortion up to a curvature of 99
- Indication of up to 50º form of harmonic wave
- Indication of the wave form with maximum value (1024 readings / period)
- Analysis of absolute distortion (%THD-F)
- Diagram of graphic equilibrium with parameters of a 3 phase system
- Detects up to 28 transistors (time and cycles) with a programmable threshold
- (%)
- Relation of 3 phases of voltage or asymmetrical current (VUR)
- Factor of 3 phases of voltage and asymmetrical current (d0%, d2%)
- USB port (optically insulated)
- Integrated timer and calendar to record data
- Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801
- ~30 mm / 1.2 in, PCE-6802 ~55 mm / 2.2 in, PCE-3007 ~170 mm / 6.7 in
Technical specifications
- AC voltage — Measuring range: 20 … 500 V
- AC voltage — Accuracy: ±0.5 % ±5 digits
- Alternating current AC — Measuring range: 0,04 … 100 A
- Alternating current AC — Accuracy: ±0.5 % ±0.05 A
- Alternating current AC: Overload Overload protection AC 200 A
- Phase angle — Measuring range: -180 … +180 °
- Phase angle — Accuracy: ±1 °
- Power factor — Measuring range: 0 … 1
- Power factor — Accuracy: ±0.04
- Frequency — Measuring range: 45 … 65 Hz
- Frequency — Resolution: 0,1 Hz
- Frequency — Accuracy: 0.1 Hz
- General technical data — Measuring functions: HOLD
- General technical data — Frequency: 50 … 60 Hz
- General technical data — Display type: LCD with backlight
- General technical data — Display size: 4,9 Inch
- Storage medium Internal memory — Storage capacity: 52420 Values
- Storage medium Internal memory — Storage interval from: 2 s
- Storage medium Internal memory — Storage interval to: 3000 min.
- Storage medium Internal memory — Interface: RS232, USB
- Storage medium Internal memory: Standard(s)IEC 61010
- Storage medium Internal memory: Maximum cable diameter 30 mm
- Storage medium Internal memory: Safety standard CAT III 600V
- Storage medium Internal memory — Menu language: English
- Storage medium Internal memory — Power supply: 12V
- Connector type Device-europlug — (Rechargeable) battery: 8 x 1,5 V AA battery , Alkali-manganese
- Connector type Device-europlug — Capacity: 3000 mAh
- Connector type Device-europlug — Operating conditions: -10 … 50 °C , 0 … 75 % RH
- Connector type Device-europlug — Storage conditions: -20 … 60 °C , 0 … 75 % RH
- Connector type Device-europlug — Dimensions: ( L x W x H )257 x 155 x 57 mm
- Connector type Device-europlug — Other dimensions: Current clamp PCE-6801 210 x 62 x 36 mm
- Connector type Device-europlug — Weight: 1160 g
- Connector type Device-europlug: Other weights Current clamp PCE-6801 200g
Delivery scope
- 1 x PCE-830 Portable Power Analyzer
- 3 x Amp clamps – PCE-6801
- 4 x Alligator clips
- 4 x Safety test lines (3 m / 3.3 ft long)
- 8 x Batteries
- 1 x Mains adaptor
- 1 x Carrying case
- 1 x USB cable software
- 1 x User’s manual