TTW 45000 Professional Air Blower
Cross-ventilation of large rooms and halls, removal of cold smoke from buildings, cooling of machinery or exhibition spaces, and dramatic ventilation for trade shows, fashion shows, or photo and film shoots — wherever high-capacity direct air transport is needed in the commercial sector, the TTW 45000 fan is the top choice.
This powerful axial fan is designed for durability, reliability, longevity, and value retention. With its extremely durable frame construction and protective grilles on both the intake and discharge sides, this fan impresses even in particularly harsh operating environments thanks to its continuous ventilation. And thanks to high-quality transport wheels with parking brakes, the unit can be moved in a flash while remaining stable when stationary.
Thanks to its unique design and high performance, the TTW 45000 fan is particularly well-suited for use in large halls and film studios:
Since the TTW 45000 can be stacked not only in the warehouse but also during operation, it can be quickly and easily integrated into your network. Install extremely large “air curtains”—and do so with an impressive volume of air!
Benefits of exercise:
100% Trotec – development, design, manufacturing
Powerful axial fan – manufactured to high industrial standards
Extremely durable for continuous professional use, even under the toughest conditions or for rental applications
High air circulation capacity
Robust unit even under harsh operating conditions
Multiple stackingfor ventilation in stacked installations and space-saving storage
Easy to use
Quick relocation thanks to transport casters
Here are some technical details of the TTW 45000:
Air volume: 45,600 m³/h
Max. air pressure: 70 Pa
Max. power consumption: 1.5 kW
Connection: 400 V / 50 Hz
Max. current consumption: 2.8 A
Throw distance: 138 m
Maximum ambient temperature: 40 °C
Fuses: 16 A
Plug: CEE 16 A, 5-pin
Sound level (at 3 m): 65 dB (A)
Length: 1395 mm
Width: 720 mm
Height: 1625 mm
Weight: 88 kg
This fan complies with the ErP 2013 guidelines for fans!
| Air volume | ||
|---|---|---|
| Maximum flow rate – free blowout [m³/h] | 45,600 | |
| Airflow | ||
| while blowing out | ||
| inhalation | ||
| Air discharge velocity | ||
| Ms. | 9.6 | |
| km/h | 34.56 | |
| Throwing Distance | ||
| outside [m] | 20 | |
| Inside [m] | 120 | |
| fan | ||
| axial | + | |
| radial | – | |
| Fan Speed | 1 | |
| Air Pressure | ||
| Maximum pressure [Pa] | 70 | |
| Conveyor Temperature | ||
| max [°C] | 40 | |
| Electrical Values | ||
| Power Connection | 400 V / 50 Hz | |
| Rated Current [A] | 2.8 | |
| Power consumption [kW] | 1.5 | |
| Recommended backup protection [A] | 10 | |
| Electrical Connection | ||
| Connection | CEE 16 A | |
| Cable length [m] | 0.7 | |
| Security Feature | ||
| IP Protection Class | 55 | |
| Sound Values | ||
| Maximum step – distance 3 m [dB (A)] | 65 | |
| dimension | ||
| Length (without packaging) [mm] | 1,395 | |
| Width (without packaging) [mm] | 720 | |
| Height (without packaging) [mm] | 1625 | |
| weight | ||
| (without packaging) [kg] | 88 | |
| EQUIPMENT, FEATURES, AND FUNCTIONS | ||
|---|---|---|
| mobility | ||
| metal wheels with rubber tires | ||
| Forklift | ||
| crane | ||
| mobile | ||
| stackable | ||