TDE 65 V2 Electric Heat Blower
A powerful, classic-style heat blower for rent and for use in construction
This extremely reliable electric space heater has proven itself as a durable solution in the construction and rental sectors for over 20 years.
The double-walled construction prevents the outer shell—made of 1.5 mm thick Zincori steel with a hardened protective coating—from overheating. This means that the body is reliably protected against corrosion even if the coating is damaged. Ideal for applications with extreme demands, such as rental or frequently changing locations.
The TDE 65 features a stainless steel air intake grille and a galvanized exhaust grille, which reduce heat radiation loss.
Thanks to its high, three-stage adjustable heating capacity, even large rooms can be heated quickly—and there is no need to ventilate them, since the TDE 65 does not consume oxygen when operating on electric heat. If necessary, heat can be transported over longer distances via a connectable hot-air hose.
Transporting this electric heater from one construction site to another is just as easy, as it is equipped with two sturdy handles made of heat-insulating material and four sturdy fixed wheels.
The TDE 65 heat blower is suitable for speeding up the drying of buildings when used in conjunction with building dehumidifiers.
Here are a few practical benefits, in brief:
- Development, design, manufacturing: 100% Trotec
- Extremely durable design—ideal for rental and frequent use on construction sites
- Double-wall construction – no insulation in the exterior wall
- Galvanized exhaust grilles
- Stainless steel air intake grille
- Hot-air hose connection option
- Overheating protection to ensure a high level of workplace safety
- Condensation-free heat—does not consume oxygen, making it suitable for use in enclosed spaces
Here are some technical specifications for the TDE 65:
- Heating capacity: 6–9–12 kW
- Fan speed: 3
- Air volume: 600 m³/h
- Voltage: 400 V
- Current: 18 A.
- Rated current / plug: 32 A / CEE 32 A, 5-pin
- Noise level (at a distance of 3 m): 63 dB (A)
- Maximum heating capacity (kcal): 10,300
- Temperature rise ΔT: 60 °C
- Dimensions L x W x H: 610 x 356 x 445 mm
- Weight in kg: 25
| heating capacity | ||
|---|---|---|
| Stage 1 [kW] | 0 | |
| Stage 2 [kW] | 6 | |
| Level 2 [kcal] | 5,160 | |
| Level 3 [kW] | 9 | |
| Level 3 [kcal] | 7,740 | |
| Level 4 [kW] | 12 | |
| Level 4 [kcal] | 10,300 | |
| Maximum Level [kcal] | 10,300 | |
| Air volume | ||
| Max. flow rate [m³/h] | 600 | |
| Air Pressure | ||
| Max. pressure [Pa] | 130 | |
| Rise in temperature | ||
| [°C] | 60 | |
| Rise in temperature | ||
| Minimum temperature [°C] | -20 | |
| Maximum temperature [°C] | 40 | |
| Fans | ||
| axial | + | |
| radial | ||
| Number of fan speeds | 1 | |
| Electrical Values | ||
| Power Connection | 400 V / 50 Hz | |
| Rated current consumption [A] | 18 | |
| Recommended protection [A] | 32 | |
| Power consumption [kW] | 12 | |
| Electrical Connection | ||
| Plug | CEE 32 A, 5-pole | |
| on the client side | ||
| Cable length [m] | 0.2 | |
| Sound Values | ||
| Distance 1 m [dB (A)] | 63 | |
| Hose Connection | ||
| Hose Connection | ||
| Diameter [mm] | 300 | |
| Maximum hose length [M] | 15 | |
| dimension | ||
| Length (without packaging) [mm] | 605 | |
| Width (without packaging) [mm] | 365 | |
| Height (without packaging) [mm] | 465 | |
| weight | ||
| (without packaging) [kg] | 25 | |