Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

Pramac GGW500G UAL gas generator

Model: Pramac GGW500G UAL. Gas Fuelled Generators are suitable for all applications that require extended run time, lower exhaust or noise emissions, or that have location constraints for on-site fuel storage, such as: healthcare, public infrastructure, transportation infrastructure, commercial buildings, data centers and industrial buildings.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Weight (kg) 4619
Ingress protection rating IP 23
Dimensions 3864 x 1747 x 2069 mm, 4705 x 1752 x 2534 mm
Noise level (dB) 68
Power supply 400/230 V / 3 ph / 50 Hz
Power (kW) 360

Model: Pramac GGW500G UAL

Which application is a Gas Generator suitable for?

Gas Fuelled Generators are suitable for all applications that require extended run time, lower exhaust or noise emissions, or that have location constraints for on-site fuel storage, such as: healthcare, public infrastructure, transportation infrastructure, commercial buildings, data centers and industrial buildings.

How do natural gas generators work?

Natural gas generators convert a gaseous supply into electricity. Differently to their diesel relatives, these generators must be able to burn a gaseous (instead of liquid) fuel. That requires a carburetor, which will be specifically designed and configured to handle pressurized gas, blending a precise quantity of fuel and air, and then inject it into the engine to make the generator run.

What are the advantages of a gas generator over a diesel generator?

Gas fuel provides virtually unlimited run-time during an electric power outage, with lower environmental impact and ease of use with the innovative Power Zone™ control system. If compared with traditional diesels, gas generator sets ensure reduced maintenance costs and simplified installation possibilities, especially in elevated areas where storage of large amounts of liquid fuel would be a concern.

Main features

  • Frequency: 50 Hz
  • Voltage: 400/230 V
  • Power factor: 0.8 cos ϕ
  • Phase: 3
  • Fuel: Natural Gas

Power rating

  • Emergency standby power esp: 500 kVA
  • Emergency standby power esp: 400 kW
  • Prime power prp: 450 kVA
  • Prime power prp: 360 kW

Rating definitions

Ratings definition (ISO-8528-1)

ESP

  • Emergency Standby Power:

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.

PRP

  • Prime Power:

It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.

G2 class load acceptance in accordance with ISO 8528-5: Higher performance classes check upon request.

Gensets are compliant with EC mark which includes the following directives and standards and subsequent modification and intregation:

• 2006/42/CE Machinery safety

• 2014/30/UE Electromagnetic compatibility

• 2014/35/UE electrical equipment designed for use within certain voltage limits

• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC) – If applicable

• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2016/1628 EC) – If applicable

• ISO 8528 as applicable

• 2011/65 ROHS

• EN 12100, EN 13857, EN 60204 as referred into the ISO8528-13

Company with quality certification ISO 9001

Engine specifications

  • Engine brand: Generac
  • Nr. of cylinder and disposition: 12 V angle
  • Displacement: 25800 cm³
  • Bore: 132 mm
  • Stroke: 160 mm
  • Compression ratio: 10:1
  • Aspiration: Turbocharged aftercooled
  • Operating speed-nominal: 1500 rpm
  • Speed governor: Electronic
  • Frequency regulation (steady state): 0.25 % (+/-)
  • Fuel: Natural Gas
  • Ignition: Electronic
  • Carburetor: Down Draft
  • Operating fuel pressure: 1.7-2.7 kPa
  • Engine cooling system: Water
  • Cooling fan: Mechanical Type
  • Coolant capacity: 78 l
  • Oil pump: Gear Type
  • Oil filtration: Twin Full Flow Type
  • Oil capacity: 95 l
  • Electric circuit: 24 V

Alternator specifications

  • Alternator: Mecc Alte
  • Model: ECO40-1L
  • Poles: 4
  • Class: H
  • Type: Brushless
  • Standard avr: M3K
  • Voltage tolerance: 1 %
  • Ip protection: 23
  • Voltage regulation system: Electronic

Fuel specifications and consumption

  • Fuel type: Natural Gas
  • Fuel consumption 75% esp: 102.0 sm³/hr
  • Fuel consumption 100% esp: 129.0 sm³/hr
  • Fuel consumption 75% prp: 94.8 sm³/hr
  • Fuel consumption 100% prp: 118.2 sm³/hr

Installation data

  • Total air flow: 632.10 m³/min
  • Exhaust gas flow: 66.5 m³/min
  • Exhaust gas temperature: 685 °C

Electrical data

  • Nominal current: 663.65 A
  • Max current (calculated on label value): 721.71 A
  • Circuit breaker: 800 A

Standard features

​ENGINE SYSTEM

  • Oil Drain Extension
  • Heavy Duty Air Cleaner
  • Fan Guard
  • Stainless Steel Flexible Exhaust Connection
  • Factory-Filled Oil And Coolant
  • Industrial Exhaust Silencer
  • Air Filter restriction indicator

Fuel System

  • Primary And Secondary Fuel Shutoff
  • Fuel Line NPT Connection

Cooling System

  • Close Coolant Recovery System
  • UV/Ozone resistant hoses
  • Factory Installed Radiator
  • 50/50 Ethylene Glycol Antifreeze
  • Radiator Drain Extension

Electrical System

  • Battery Charging Alternator
  • Battery Cables
  • Battery Tray
  • Rubber-Booted Engine Electrical Connections
  • Solenoid Activated Starter Motor

ALTERNATOR SYSTEM

  • Class H Insulation Material
  • 2/3 Pitch
  • Skewed Stator
  • Auxiliary Winding Excitation System
  • Sealed Bearing
  • Amortisseur Widing
  • Full-Load Capacity Alternator

GENERATOR SET

  • Internal Genset Vibration Isolation
  • Wrapped Exhaust Piping (Enclosed Only)
  • Bottom (floor) power cable outlet
  • 1-year Warranty or 1000 hours
  • Exhaust silencer Mounted in the Discharge Hood (Enclosed Sets)
  • Baseframe: ENCLOSURE (if selected) High-Performance Sound Absorbing Material Gasketed Doors Galvanized Sheet Metal Construction Upward Facing Discharge Hood (exhaust) Stainless Steel Hinges

Control panel – options available:

  • Automatic control panel: ACP
  • Modular parallel panel: MPP

Acp – automatic control panel

Power Zone® Advanced integrated gen-set control platform that includes al drives and functions to manage the gas gen-set and perform an optimal combustion of the fuel, while maximizing performance. User Interface (UI)

  • 7″ Colour Display with touch screen
  • User-friendly icons
  • Remote Connection via WiFi or Bluetooth

Mode of Operation

  • Manual – Automatic (ACP)
  • Single gen-set automatic start (2-Wire)
  • Second part of the text: ​Program Functions Programmable Crank Limiter 7-Day programmable Excerciser RS232/485 Communications LAN communication 3-Phase sensing Voltage Regulator 2-Wire start Capability Date/Time Fault History (event Log) Isochronus Governor Control Audible Alarms and shutdown Auto On/Off Manual Switch E-Stop Button (Mushroom) Customizable Alarms, Warnings, Events Modbus protocol Predictive Maintenance Algorithm Sealed Boards Password Parameter Adjustment Protection Single Point Ground Alarm Information Automatically Announced on the touchscreen display
  • Third part of the text: Full System Status Display Power Output (kW) Power Factor Cos(φ) kWh total and last run Active/Reactive/Apparent Power All Phase AC voltage All Phase Currents Oil Pressure Coolant Temperature Coolant Level Engine Speed Battery Voltage Frequency
  • Part4: Alarms And Warnings Oil Pressure Coolant Temperature Coolant Level Low Fuel Pressure Alarm Engine Overspeed Battery Voltage Alarms and Warnings times and date staped Snap Shot of key Operation Parameters during Alarms and Warnings Alarms and Warinings Spelled Out (No Alarm Codes) Multilingual Other Protections 3 Poles circuit breaker Emergency stop button 4-Poles circuit breaker (Optional TIF)

Mpp – modular parallel panel

Deep Sea Electronics DSE G8600 Controller

The G8600 is a parallel genset controller with integral heater designed for complex paralleling applications. The G8600 can be configured to provide paralleling for up to 32 generators on a single site and provides a wide range of high-end features for multiple application environments. Features

  • Multiple bus sectioning
  • Group controller functionality
  • Spinning reserve
  • Load demand schemes
  • Advanced MSC link (AMSC)
  • Advanced PLC functionality
  • Multi-purpose PIDs
  • Phase locking
  • Virtual inputs
  • On-screen mimic (SLDs)
  • Multiple application support
  • Multi-level pin protected front panel editor
  • Integral LCD display heater
  • Enhanced high-resolution 240 x 128 pixel display
  • Single or multiple generator control
  • Load sharing & VAr sharing
  • Virtual shared inputs, outputs and data via AMSC
  • Touch screen panel PC support (DSE SCADA)
  • Zero sequence voltage protection
  • Integral gasket (IP65 protection)
  • Second part of the text: Built-in governor & AVR control DSE digital AVR support Base load (kW export) control Positive & negative kVAr export control Dead bus synchronising Mains (utility) decoupling protection Multiple language support 3-phase generator sensing & protection 3-phase mains (utility) sensing 3-phase bus sensing Mains (utility) failure detection Generator current, protection & power monitoring Configurable timers Integrated SNMP Data logging PC configuration DSENet® (Expansion support) Flexible I/O (inputs/outputs) Automatic and front panel breaker control Power-save mode
  • Part4: Other Protections 3 Poles motorized circuit breaker Emergency stop button 4 Poles motorized circuit breaker (optional TIF)

Dimensional data open version

  • Length: 3864 (L) mm
  • Width: 1747 (W) mm
  • Height: 2069 (H) mm
  • Weight: 4619 kg

Dimensional data canopy version

  • Length: 4705 (L) mm
  • Width: 1752 (W) mm
  • Height: 2534 (H) mm
  • Weight: 5941 kg

Noise level

  • Guaranteed noise level (lwa): 98 dB(A)
  • Noise pressure level @ 1 m: 78 dB(A)
  • Noise pressure level @ 7 m: 68 dB(A)

Genset equipment

  • Coolant pre-heating system (convection type): PHS
  • 3-way catalytic muffler: CAT
  • Upsized alternator: UAL
  • Alternator anti-condensation heater: ACH
  • Permanent magnet generator on alternator: PMG
  • Genset metal nameplate: GMN
  • Starting batteries: BAT
  • Automatic lube oil top up system with lube oil tank: ALS
  • Different canopy color: DCC

Datasheet (PDF)

FAQ