Weight (kg) 2535
Ingress protection rating IP 23
Material Galvanized steel
Dimensions 3400 x 1250 x 1980 mm
Noise level (dB) 65
Tank capacity (L) 350
Power supply 400 V / 3 ph / 50 Hz
Power (kW) 161.78

Model: Pramac GSW220V (Alt. LS)

Main features

  • Frequency: 50 Hz
  • Voltage: 400 V
  • Power factor: 0.8 cos ϕ
  • Phase: 3

Power rating

  • Emergency standby power esp: 220.00 kVA
  • Emergency standby power esp: 176.00 kW
  • Prime power prp: 202.23 kVA
  • Prime power prp: 161.78 kW

Rating definitions

Ratings definition (ISO-8528-1)

ESP

  • Emergency Standby Power:

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.

PRP

  • Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.

Engine specifications

  • Engine brand: Volvo
  • Model: TAD733GE
  • [50hz] exhaust emission level: Stage II
  • Engine cooling system: Water
  • Nr. of cylinder and disposition: 6 in line
  • Displacement: 7150 cm³
  • Aspiration: Turbocharged intercooled
  • Speed governor: Electronic
  • Prime gross power prp: 181 kW
  • Maximum gross power ltp esp: 201 kW
  • Oil capacity: 34 l
  • Lube oil consumption prp (max): 0.10 %
  • Coolant capacity: 38.4 l
  • Fuel: Diesel
  • Specific fuel consumption 75% prp: 214 g/kWh
  • Specific fuel consumption prp: 216 g/kWh
  • Starting system: Electric
  • Starting engine capability: 5 kW
  • Electric circuit: 12 V

Engine equipment

  • Starting system: ENGINE EQUIPMENT Standards The engine performance corresponds to ISO 3046, BS 5514 and DIN 6271. Power output guaranteed within 0 to +2% att rated ambient conditions at delivery. Ratings are based on ISO 8528. Engine speed governing in accordance with ISO 3046/IV, class A1 and ISO 8528-5 class G3 Engine and block • Optimized cast iron cylinder block with optimum distribution of forces • Drop forged steel connecting rods • Keystone top compression rings for long service life • Replaceable valve guides and valve seats Fuel system • Washable fuel prefilter with water separator • Fine fuel filter of disposable type • Rotary low-pressure fuel pump Lubrication system • Rotary displacement oil pump driven by the crankshaft • Deep centre oil sump – Oil filler on top – Oil dipstick, short in front • Integrated full flow oil cooler, side-mounted– Integrated full flow oil cooler, side-mounted Cooling system • Belt driven, maintenance-free coolant pump with high degree of efficiency • Efficient cooling with accurate coolant control through a water distribution duct in the cylinder block • Reliable thermostat with minimum pressure drop

Alternator specifications

  • Alternator: Leroy Somer
  • Model: LSA46.3 S3
  • Voltage: 400 V
  • Frequency: 50 Hz
  • Power factor: 0.8 cos ϕ
  • Poles: 4
  • Type: Brushless
  • Voltage tolerance: 0.5 %
  • Efficiency @ 75% load: 93.1 %
  • Class: H
  • Ip protection: 23

Alternator equipment

  • Mechanical structure text: SPECIALLY ADAPTED TO APPLICATIONS The alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. TOP OF THE RANGE ELECTRICAL PERFORMANCE ● Class H insulation. ● Standard 12 wire re-connectable winding, 2/3 pitch, type no. 6. ● High efficiency and motor starting capacity. ● R 791 interference suppression conforming to standard EN 55011 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM ● Excitation system: AREP
  • Voltage regulator text: REINFORCED MECHANICAL STRUCTURE ● Compact rigid assembly to better withstand generator vibrations. ● Steel frame ● Cast iron flanges and shields. ● Single-bearing designed to be suitable for heat engines. ● Half-key balancing bearing. ● Sealed for life ball bearing. PROTECTION SYSTEM SUITED TO THE ENVIRONMENT ● The LSA is IP 23. ● Winding Protection for clean environments with relative humidity ≤ 95%, including indoor marine environments. COMPLIANT WITH INTERNATIONAL STANDARDS The LSA alternator conforms to the main international standards and regulations: – IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA / UL 1146 (UL 1004 on request), marine regulations, etc. The LSA  is designed, manufactured and marketed in an ISO 9001 environment and ISO 14001.

Genset equipment

BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH:

• Anti-vibration mountings properly sized

• Welded or Screwed support legs. (according to canopy size)

OIL DRAININ PIPE WITH CAP : • Oil draining facilities ENGINE COMPLETE WITH: • Battery • Liquids (no fuel)

CANOPY : • Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. • Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles; Detachable panels, with screws holes protected by rubber tap. • Control panel protection door provided with suitable window and lockable handle. • Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. • Single detachable lifting eye placed on the roof.

  • Baseframe: PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: • Filler neck • Air breather (ventilation pipe) • Minimum fuel level sensor
  • Text noise: SOUNDPROOF : • Noise attenuation thanks to soundproofing material • Efficient residential silencer placed inside the canopy

Dimensional data

  • Length: 3400 (L) mm
  • Width: 1250 (W) mm
  • Height: 1980 (H) mm
  • Dry weight: 2535 kg
  • Fuel tank capacity: 350 l
  • Fuel tank material: Plastic

Autonomy

  • Fuel consumption @ 75% prp: 34.76 l/h
  • Fuel consumption @ 100% prp: 46.54 l/h
  • Running time 75% prp: 10.07 h
  • Running time 100% prp: 7.52 h

Noise level

  • Guaranteed noise level (lwa): 94 dB(A)
  • Noise pressure level @ 7 m: 65 dB(A)

Installation data

  • Total air flow: 238.30 m³/min
  • Exhaust gas flow: 31.8 m³/min
  • Exhaust gas temperature: 530 °C

Electrical data

  • Battery capacity: 140 Ah
  • Max current: 317.55 A
  • Circuit breaker: 320 A

Control panel availability

  • Manual control panel: MCP
  • Manual control panel full option: MPF
  • Automatic control panel: ACP
  • Modular parallel panel: MPP

Mcp – manual control panel

Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle.

INSTRUMENTATION (ANALOGUE)

• Voltmeter (1 phase)
• Ammeter (1 phase)
• Hours-counter

COMMANDS

• Start/stop selector switch with key
• Emergency stop button

  • Second part of the text: PROTECTION WITH ALARM • Low fuel level • Battery charger failure • low oil pressure • high engine temperature • Earth Fault.
  • Third part of the text: PROTECTIONS WITH SHUTDOWN • Low fuel level • Battery charger failure • low oil pressure • high engine temperature. • Circuit breaker protection: III poles • Emergency stop button
  • Part4: OTHERS PROTECTIONS • Panel protected through door with lockable handle.

Out put panel mcp

  • External terminal board (etb): Optional
  • Socket kit: Optional

Mpf – manual control panel full option

Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle

INSTRUMENTATION (ANALOGUE)

• Voltmeter with selector switch (3 phases)
• Frequency meter
• Ammeter with selector switch (3 phases)
• Hours-counter
• Fuel level indicator
• Oil pressure indicator
• Engine temperature indicator

COMMANDS

• Start/stop selector switch with key
• Emergency stop button

  • Second part of the text: PROTECTION WITH ALARM • Low fuel level • Battery charger failure • low oil pressure • high engine temperature • Earth Fault
  • Third part of the text: PROTECTIONS WITH SHUTDOWN • Low fuel level • Battery charger failure • low oil pressure • high engine temperature • Circuit breaker protection: III poles • Emergency stop button
  • Part4: OTHERS PROTECTIONS • Panel protected through door with lockable handle

Out put panel mpf

  • Etb- external terminal board: ETB
  • Socket kit: Standard
  • Individual cb and earth fault protection: √
  • 3p+n+t 400v 63a ip67: 1 n
  • 3p+n+t cee 400v 16a ip67: 1 n
  • 230v/16a 2p+t cee ip67: 1 n
  • 230v 16a schuko ip68: 1 n

Acp – automatic control panel

Mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set, protected through door with lockable handle

DIGITAL INSTRUMENTATION
• Generating set voltage (3 phases)
• Mains voltage
• Generating set frequency
• Generating set current (3 phases)
• Battery voltage
• Power (kVA – kW – kVAr)
• Power factor Cos φ
• Hours-counter
• Engine speed r.p.m.
• Fuel level (%)
• Engine temperature (depending on model)

  • Second part of the text: COMMANDS AND OTHERS • Four operation modes: OFF – Manual starting – Automatic starting – Automatic test • Pushbutton for forcing Mains contactor or Genset contactor • Push-buttons: start/stop, fault reset, up/down/page/enter selection • Remote starting availability • DC system disconnection switch • Acoustic alarm • Automatic battery charger • RS232 Communication port • Settable PASSWORD for protection level
  • Third part of the text: PROTECTIONS WITH ALARM • Engine protections: low fuel level, low oil pressure, high engine temperature • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN • Engine protections: low fuel level, low oil pressure, high engine temperature • Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure • Circuit breaker protection: III poles • Earth Fault included in the control unit
  • Part4: OTHERS PROTECTIONS • Emergency stop button • Panel protected through door with lockable handle

Out put panel acp

  • Predisposed for remote control optional:: RCG
  • External terminal board (etb): Optional
  • Socket kit: Optional

Mpp – modular parallel panel

  • Part mpp: Mounted on the genset, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple gen-sets operating in standby or parallel modes (up to 32 gen-sets in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) • Mains: voltage, Intensity, Frequency. • Mains kW – kVAr -Power factor Cos f. • Generating set voltage (3 phases). • Generating set frequency. • Generating set current (3 phases). • Generating set Power (kVA – kW – kVAr). • Generating set Power factor Cos f. • Generating set kWh and kVAh. • Battery voltage. • Hours-counter. • Engine speed r.p.m. • Fuel level (%). • Engine temperature (depending on model). • Oil pressure (depending on model).
  • Second part of the text: COMMAND AND OTHERS • Graphical display 128×64 pixels. • Operation modes: OFF – AMF function – Single Parallel to mains Island application – Single Parallel to Mains AMF application – Multiple parallel genset Island application. • Pushbutton for forcing Mains Breaker/contactor or Genset Breaker/contactor. • Push-buttons: start/stop, fault reset, up/down/page/enter selection. • Multiple parallel and Power Management operation with digital load  AVR sharing. • Automatic synchronizing and power control (via speed goveroner or ECU) • Baseload Import/Export and Peak shaving • Voltage and PF control (AVR). • Configurable digital I/O (12/12) and analogue inputs (3). • Integrate PLC programmable functions. • Event-based history (up to 500records). • Selectable measurement range 120/277V and 0-1/0-5A. • Remote starting and Blocking signal availability. • DC system disconnection switch. • Acoustic alarm. • Automatic battery charger. • 2xRS232/RS485/USB Comunication ports. • Settable PASSWORD for protection level.
  • Third part of the text: PROTECTION WITH ALARM AND SHUTDOWN • Engine protections: low fuel level, low oil pressure, high engine temperature. • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage • Others: overcurrent, shortcircuit, reverse power, Earth fault
  • Part4: OTHERS PROTECTION : • Circuit breaker protection: IV poles Motorized. • Emergency stop button. • Panel protected through door with lochetable handle

Out put panel mpp

  • Multi-pin connectors (in and out ) for parallel with other generators: 2 n
  • Connecting cable with 2 connectors multipin (length 10m): 1 n
  • External terminal board: ETB

Optional features:

  • To be ordered with equipment (when necessary): :

Control panel supplement

  • Rcg – various supplements for remote controls – available for models:: ACP MPP
  • Tlp – various supplements for remote signals – available for models:: ACP MPP
  • Adi – adjustable differential intensity – available only for models:: ACP
  • Tif – iv poles circuit breaker instead of iii – available for models:: ACP MCP
  • Etb – external terminal board – available for models:: MCP ACP

Socket kit

  • Skb socket kit b – available for models:: ACP MCP
  • Component version: IP67
  • Individual cb and earth fault protection: √
  • 3p+n+t 400v 63a ip67: 1 n
  • 230v/16a 2p+t cee ip67: 1 n
  • 230v 16a schuko ip68: 1 n
  • 3p+n+t cee 400v 16a ip67: 1 n
  • Nb: for assembly is necessary:: ETB

Genset equipment

  • Automatic fuel pump: ACP MPP

Extended fuel tank

  • Fuel tank capacity: 1750 l
  • Length (genset): 3414 (L) mm
  • Width (genset): 1398 (W) mm
  • Height (genset): 2749 (H) mm

Engine supplements

  • Coolant pre-heating system: PHS

Datasheet (PDF)