Model: Pramac GDW_335V/FS2
Which application is GDW Series suitable for?
The GDW Series is designed for emergency standby and continuous power applications: Hospital, Data Center, Retail, Oil & Gas, Mining, Power Plant Production, Mining, Oil & Gas, Water treatment, among others.
Which versions of GDW are available?
The GDW Series is avaliable in three versions: Open, Silenced Enclosure and Extra Silenced Enclosure.
Each version has a sturdy design with robust structure and enclosure. Large control and power sections to meet any power plants requirements. Modular design with a basic core configuration compatible with a wide list of modules, able to cover all stationary application needs.
Power rating
- Emergency standby power esp: 330.0 kVA
- Emergency standby power esp: 264.0 kW
- Prime power prp: 300.0 kVA
- Prime power prp: 240.0 kW
- Voltage: 400/230
- Frequency: 50
- Power factor: 0.8 cos ϕ
- Phases: 3
- Fuel: Diesel
Rating definitions
Ratings definition (ISO-8528-1)
ESP
- Emergency Standby Power:
It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.
PRP
- Prime Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.
G2 class load acceptance in accordance with ISO 8528-5: Higher performance classes check upon request.
Engine specifications
- Engine brand: Volvo
- Model: TAD842GE
- Operation speed nominal: 1500 rpm
- Engine cooling system: Water
- Exhaust emission level: Stage II
- Nr. of cylinder and disposition: 6 in line
- Displacement: 7700 cm³
- Aspiration: Turbocharged Type
- Speed governor: Electronic
- Gross engine power esp: 299 kWm
- Gross engine power prp: 273 kWm
- Fan power: 12 kWm
- Fan air flow: 423 m³/min
- Total oil capacity: 27 l
- Total coolant capacity: 36 l
- Fuel: Diesel
- Specific fuel consumption 100% esp: 196 g/kWh
- Specific fuel consumption 75% prp: 201 g/kWh
- Starting system: Electric
Alternator specifications
- Alternator brand: Mecc Alte
- Model: ECO38 1L4 C
- Winding: Standard
- Winding connections: Series Star Type
- Frequency: 50 Hz
- Voltage: 400 V
- Phases: 3
- Power factor: 0.8 cos ϕ
- Stand-by rating 27°c: 330 kVA
- Continuous nominal rating 40°c: 300 kVA
- Efficiency @ 100% of load: 93.7 %
- Type: Brushless
- Poles: 4
- Voltage tolerance: 1 %
- Class: H
- Ip protection: 23
Installation data
- Total air flow: 473 m³/min
- Exhaust gas flow prp: 18 m³/min
- Exhaust gas temperature: 455 °C
- Fuel consumption 75% prp: 48.69 l/h
- Fuel consumption 100% prp: 63.20 l/h
Fuel tank – options available:
- Mft-xs running time 75% prp: 10.27 h
- Mft-s running time 75% prp: 12.32 h
- Mft-m running time 75% prp: 20.54 h
- Mft-l running time 75% prp: 45.18 h
Fuel tank – options available:
- Metal fuel tank: XS Type
- Mft-xs fuel tank capacity: 500 l
- Mft-xs fuel tank location: Internal
- Metal fuel tank: S Type
- Mft-s fuel tank capacity: 600 l
- Mft-s fuel tank location: Internal
- Metal fuel tank: M Type
- Mft-m fuel tank capacity: 1000 l
- Mft-m fuel tank location: With sub-base
- Mft-m extra length (only for open versions): 647 mm
- Mft-m extra height (for open/canopy versions): 340 mm
- Mft-m extra weight: 548 kg
- Metal fuel tank: L Type
- Mft-l fuel tank capacity: 2200 l
- Mft-l fuel tank location: With sub-base
- Mft-l extra length (only for open versions): 647 mm
- Mft-l extra height (open/canopy versions): 655 mm
- Mft-l extra weight: 826 kg
Electrical data
- Genset voltage: 400/230 V
- Frequency: 50 Hz
- Phases: 3
- Power factor: 0.8 cos ϕ
- Max current: 476 A
- Nominal current: 433 A
- Circuit breaker: 500 A
Acp – automatic control panel
- Auto Mains Failure (AMF) function
- Gen-set controller for single genset operating in standby or prime power modes
- Full gen-set monitoring and protection
- Detailed event and performance log with time and date
- Wide range of remote control modules available as option
- Wide range of I/O expansion modules available as option
Power supply by circuit breaker and/or terminal bus bar
Open version
- Baseframe made of welded steel profile
- Anti-vibration mountings properly sized
- Screwed support legs
- Hole for handling by crane
- Moving and rotating parts protection against accidental contact
- Grounding point to connect all metal parts to ground
Dimensional data open version
- Length: 3055 (L) mm
- Width: 1200 (W) mm
- Height: 1795 (H) mm
Dimensional data open version
- Weight: 2151 kg
Options available (only for open version)
- Residential exhaust system: RES
Canopy version
- Weatherproof Enclosure made of galvanized sheet metal allows to protect genset from corrosion and aggressive condition
- Soundproofed enclosure tanks to high quality soundproof material and residential silencer, allows to have low noise emission level
- Big large lateral doors allows an easy service and maintenance operation
- Doors equipped with key lockable handles
- Baseframe made of welded steel profile
- Anti-vibration mountings properly sized
- Screwed support legs
- Hole for handling by crane
- Moving and rotating parts protection against accidental contact
- Grounding point to connect all metal parts to ground
Dimensional data canopy version
- Length: 3950 (L) mm
- Width: 1200 (W) mm
- Height: 2050 (H) mm
Dimensional data canopy version
- Weight: 2958 kg
Noise level canopy version
- Guaranteed noise level (lwa): 97 dB(A)
- Noise pressure level @ 1 m: 78 dB(A)
- Noise pressure level @ 7 m: 68 dB(A)
Options available (only for canopy versions)
- Roof lifting point: RLP
Optional features
- To be ordered with equipment (when necessary): :
- Pre-heating system: PHS
- Manual battery switch: MBS
- Air shut-off valve: ASV
- Heavy-duty air filter: HDF
- Water separator filter: WSP
- Winding total protection: WTP
- Alternator anti-condensation heater: ACH
- Galvanized skid base with fork lift point: GSB