Model: Pramac GBW15Y
Main features
- Frequency: 50 Hz
- Voltage: 230 V
- Power factor: 1 cos ϕ
- Phase: 1
Power rating
- Emergency standby power esp: 10.76 kVA
- Emergency standby power esp: 10.76 kW
- Prime power prp: 10.08 kVA
- Prime power prp: 10.08 kW
Rating definitions
Ratings definition (ISO-8528-1)
ESP
- Emergency Standby Power:
It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.
PRP
- Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.
Engine specifications
- Engine brand: Yanmar
- Model: 3TNV88F-UGPGE
- [50hz] exhaust emission level: Stage V
- Engine cooling system: Water
- Nr. of cylinder and disposition: 3 in line
- Displacement: 1642 cm³
- Aspiration: Natural
- Speed governor: Mechanical
- Prime gross power prp: 12.4 kW
- Maximum gross power ltp esp: 13.2 kW
- Oil capacity: 6.7 l
- Coolant capacity: 2 l
- Fuel: Diesel
- Specific fuel consumption 75% prp: 227 g/kWh
- Specific fuel consumption prp: 225 g/kWh
- Starting system: Electric
- Starting engine capability: 1.2 kW
- Electric circuit: 12 V
Engine equipment
- Starting system: Engine Equipment Standards The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1 Fuel system • Direct injection system • Fuel filter paper element • Fuel pump Bosch in-Line Lube oil system • Forced feed system • Trochoid pump • Paper element lube oil filter Induction system • Mounted air filter Cooling system • Thermostatically-controlled system with gear-driven circulation pump and belt-driven pusher fan • Mounted radiator and piping
Alternator specifications
- Alternator: Linz
- Model: E1S13ME
- Voltage: 230 V
- Frequency: 50 Hz
- Power factor: 1 cos ϕ
- Poles: 4
- Type: Brushes
- Voltage tolerance: 1.5 %
- Efficiency @ 75% load: 85.22 %
- Class: H
- Ip protection: 21
Alternator equipment
- Mechanical structure: Mechanical structure
- Mechanical structure text: Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups.
- Voltage regulator text: Output voltage wave form: The low harmonic content (<5%) allows supplying any type of load, including distorting loads. Overload: 10% overload for one hour every 6 hours is normally accepted. Short overloads can be very high (three times the rated current).
Genset equipment
BASE FRAME MADE OF WELDER STEEL PROFILE, COMPLETE WITH:
• Anti-vibration mountings properly sized
• Visual fuel level indicator
• Integrated support legs.
OIL DRAININ PIPE WITH CAP: • Oil draining facilities
PROTECTIONS : • Moving and rotating parts protections against accidental contacts ENGINE COMPLETE WITH: • Battery • Liquids (no fuel)
- Baseframe: PLASTIC FUEL TANK, COMPLETE WITH: • Filler neck • Air breather • Fuel refilling
- Text noise: EXHAUST (Standard) : • Industrial silencer
Dimensional data
- Length: 1600 (L) mm
- Width: 870 (W) mm
- Height: 950 (H) mm
- Dry weight: 395 kg
- Fuel tank capacity: 51 l
- Fuel tank material: Plastic
Autonomy
- Fuel consumption @ 75% prp: 2.53 l/h
- Fuel consumption @ 100% prp: 3.32 l/h
- Running time 75% prp: 20.16 h
- Running time 100% prp: 15.36 h
Installation data
- Total air flow: 29.80 m³/min
- Exhaust gas flow: 0.026 m³/min
- Exhaust gas temperature: 425 °C
Electrical data
- Battery capacity: 70 Ah
- Max current: 46.78 A
- Circuit breaker: 50 A
Control panel availability
- Manual control panel: MCP
- Automatic control panel: ACP
Mcp – manual control panel
Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets
INSTRUMENTATION (ANALOGUE)
• Voltmeter (1 phase)
• Ammeter (1 phase)
• Hours-counter
- Second part of the text: COMMANDS AND OTHERS • Start/stop selector switch with key (Glow plugs preheating function also included). • Emergency stop button installed on canopy side.
- Third part of the text: PROTECTION WITH ALARM • Battery charger failure • low oil pressure • high engine temperature • Earth Fault. PROTECTIONS WITH SHUTDOWN • Battery charger failure • low oil pressure • high engine temperature. • Circuit breaker protection
- Part4: OTHERS • Emergency stop button
Out put panel mcp
- Power cables connection to circuit breaker.: √
Acp – automatic control panel
Automatic control panel mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set.
INSTRUMENTATION DIGITAL
• Mains voltage.
• Generating set voltage (3 phases).
• Generating set frequency.
• Generator set current.
• Battery voltage
• Hours-counter.
- Second part of the text: COMMANDS AND OTHERS • Operation modes: OFF – Manual Starting – Automatic Starting. • Push-buttons: start/stop, fault reset, up/down/page/enter selection. • Emergency stop button. • Remote starting availability. • Automatic battery charger. • USB port.
- Third part of the text: PROTECTIONS WITH ALARM • Engine protections: low oil pressure, high engine temperature • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure PROTECTIONS WITH SHUTDOWN • Engine protections: low oil pressure, high engine temperature • Genset protection: under/over voltage, overload, under/over battery voltage • Circuit breaker protection
- Part4: OTHERS • Cover protection Power switch
Out put panel acp
- Plinth row for connection from acp to lts panel.: √
- Power cables connection to circuit breaker.: √
Optional features:
- To be ordered with equipment (when necessary): :
Engine supplements
- Coolant pre-heating system: PHS