PCE Instruments PCE-FST-200-201-H-U wind speed alarm / wind alarm controller

Wind Sensor PCE-FST-200-201-H-U. **Robust wind sensor for permanent installation / Powder coating /.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Kaitseklass IP55
Liides Analoogväljund 0 ... 10 V, Analoogväljund 4 ... 20 mA
Mõõdetav suurus Tuulekiirus
Power supply 12-36 V DC

Wind Sensor PCE-FST-200-201-H-U

**Robust wind sensor for permanent installation / Powder coating /

Weatherproof, by use of seals / Heating**

The wind speed sensor is compatible with and can be mounted on to a wide variety of available measuring equipment. The sensor will detect even the minutest movements of air and the results are then output in analogue form.

The sensor is manufactured from corrosion resistant alloy, thus making it impervious to oxidation or rust. This allows the device to be used in the toughest environments. Sensitive parts are protected with seals, to prevent the ingress of water or fine dust. A heating element prevents the sensor from freezing. The PCE-FST-200-201-H wind speed sensor is a cup anemometer and is sensitive to wind speed down to as little as, less than 0.5 meters per second. The wind speed sensor is available in different versions with different outputs. This one is available with 4 … 20-mA output and a 0 … 10V DC output.

Highlights

  • Alloys
  • Heating
  • Seal protection
  • Analogue output signal
  • Easy assembly
  • Detects minutest movements of air

Technical specifications

  • Output signal0 … 10 V
  • Operating voltage 12 … 36V DC
  • Measurement reading range 0.5 m/s … 50 m/s (1.1 … 111.8 mph)
  • Measurement readings from≤ 0.5 m/s (1.1 mph)
  • Measurement reading accuracy± 0.5 m/s (1.1 mph), (< 5 m/s (11.2 mph))
  • ± 3% from scale end value
  • Heat output 10 W at 24V DC
  • Operating temperature range-20 … 85°C/ -4 … 185°F, at ≤ 95% rel. humidity
  • Maximum wind speed 70 m/s (156.6 mph) at max. 30 minutes
  • Power connection M12
  • Protection class: IP55

Delivery scope

  • 1 x Wind Speed Sensor PCE-FST-200-201-H
  • 1 x Plug M12
  • 1 x 3 m / 9.8 ft cable
  • 1 x Operating Manual