Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-CT 5000H surface testing - coating thickness gauge

PCE-CT 5000H Surface Testing – Coating Thickness Gauge Non-destructive coating and dry film thickness (DFT) measuring device for use on ferrous (Type F) and non-ferrous (Type N) metal substrates. PCE-CT 5000H is a surface-testing coating thickness measuring instrument used for the rapid determination of coating thicknesses on ferrous (Type F) and non-ferrous (Type N) metals.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Andmemälu maht 2000 väärtust
Andmemälu tüüp Sisemälu
Anduri tüüp Magnetinduktsiooniandur, Pöörisvooluandur
Ekraan LCD
Eraldusvõime Kattekihi paksus: 0,01 µm, Kattekihi paksus: 0,1 µm, Kattekihi paksus: 1 µm
Weight (kg) 0.0745
Kalibreerimine Kalibreerimissertifikaat valikuline, Kalibreerimisstandard komplektis
Liides Mini-USB
Mõõtefunktsioonid Alarm, Automaatne väljalülitus, Keskmine väärtus, Maksimaalväärtus, Minimaalväärtus
Mõõteintervall 2 korda sekundis
Mõõdetav suurus Kattekihi paksus
Dimensions 110 x 53 x 24 mm
Toiteallikas Patarei
Töötingimused (% RH) 20 - 90
Töötingimused (°C) 0 - 50

PCE-CT 5000H Surface Testing – Coating Thickness Gauge Non-destructive coating and dry film thickness (DFT) measuring device for use on ferrous (Type F) and non-ferrous (Type N) metal substrates

PCE-CT 5000H is a surface-testing coating thickness measuring instrument used for the rapid determination of coating thicknesses on ferrous (Type F) and non-ferrous (Type N) metals. The coating thickness gauge automatically detects the type of metal to be measured. The PCE-CT 5000H coating thickness gauge uses magnetic induction (ferrous) or eddy current (non-ferrous) to take non-destructive measurements of coating and dry film thickness (DFT) on metal substrates such as steel and aluminum.

This thickness gauge is ideal for painted and powder-coated surface testing, automotive paint inspection, coated material testing, and manufacturing quality control applications. Alarm limits can be set in the coating thickness gauge to notify the user when a coating is too thick or too thin. If a coating thickness measurement falls outside the established limits, a message appears on the display to alert the user.

Highlights

  • Designed for non-destructive testing and inspection
  • Measures coating thickness on Fe and nFe metals
  • Displays measuring units in μm, mm or mils
  • Saves up to 2000 measurements to internal memory
  • Practical V-groove on the measuring head
  • One- to four-point and zero calibration
  • Comfortable one-handed operation
  • Programmable alarm limits
  • High measuring range
  • High measuring accuracy
  • Automatic shutdown
  • Optional ISO calibration certificate available for purchase separately – see
  • accessories tab for details

Technical specifications

  • Layer thickness — Measuring range: 0 … 99,9 µm
  • Layer thickness — Resolution: 0,1 µm
  • Layer thickness — Accuracy: ±(2% +1 µm)
  • Layer thickness — Measuring range: 100 … 999 µm
  • Layer thickness — Resolution: 1 µm
  • Layer thickness — Accuracy: ±(2% +1 µm)
  • Layer thickness — Measuring range: 1000 … 5000 µm
  • Layer thickness — Resolution: 0,01 µm
  • Layer thickness — Accuracy: ±(2% +1 µm)
  • Sensor — Measuring range: 0 … 3000 mm
  • Sensor — Battery: type Eddy current mode (NFe)
  • Sensor: Min. measuring surface 20 mm
  • Sensor: Min. layer thickness 0.05 mm
  • Sensor: Min. radius of curvature convex 5 mm
  • Sensor: Min. radius of curvature concave 25 mm
  • Sensor — Measuring range: 0 … 5000 mm
  • Sensor — Battery: type Magnetic mode (Fe)
  • Sensor: Min. measuring surface 20 mm
  • Sensor: Min. layer thickness 0.05 mm
  • Sensor: Min. radius of curvature convex 5 mm
  • Sensor: Min. radius of curvature concave 25 mm
  • General technical data — Measuring functions: MIN, MAX, Average value
  • Units µm, mm, mils — Display type: LCD
  • Units µm, mm, mils — Display size: 1,6 Inch
  • Units µm, mm, mils: Display resolution 128 x 128
  • Units µm, mm, mils: Measuring rate 2 x per second
  • Storage medium Internal memory: Memory information- Direct measurement: Measurement results are only stored temporarily in RAM and are deleted when the device is switched off; when the RAM is full, the oldest value is
  • is replaced by the latest.: Four data groups (automatic measurement data storage of a maximum of 2000 measured values) are retained when the device is switched off; when the memory is full, the device displays “FL”.
  • is replaced by the latest. — Interface: Mini-USB
  • is replaced by the latest.: Automatic power-off 3 min
  • is replaced by the latest. — Housing: ABS (acrylonitrile-butadiene-styrene copolymers)
  • Alarm optical — Calibration: One-point to four-point calibration, zero calibration
  • Alarm optical: Alarm settings 0 … 5250 µm
  • Alarm optical — Menu language: German, English, Russian, Chinese
  • Alarm optical — (Rechargeable) battery: 2 x 1,5 V AAA battery , Alkali-manganese
  • Alarm optical — Capacity: 1200 mAh
  • Alarm optical — Operating conditions: 0 … 50 °C , 20 … 90 % RH
  • Alarm optical — Storage conditions: -10 … 60 °C , 20 … 90 % RH
  • Alarm optical — Dimensions: ( L x W x H )110 x 53 x 24 mm
  • Alarm optical — Weight: 74,5 g

Delivery scope

  • 1 x PCE-CT 5000H Surface Testing
  • 2 x Zero calibration plates (ferrous and non-ferrous)
  • 5 x Calibration plates
  • 2 x 1.5V AAA batteries
  • 1 x USB cable
  • 1 x PC-compatible software
  • 1 x User manual
  • 1 x Carrying case

Documents

FAQ