Model: Pramac SP12000 400V IP54 #AVR #IPP
THE COMPLETE PROTECTION
This genset has an exceptional quality and strength; it responds to all EEC markets requirements. It is a rare product, with such power, to complying with the EU regulations on noise emission (2000/14/CE). SP 12000 offers a top equipment as standard: insulation monitoring, automatic voltage regulator, IP 54 protection of the control panel and the alternator, for comfort and safety.
What kind of applications is the SP Series suitable for?
The SP Series ensure performance in a wide variety of applications, such as renovation works, industrial, lighting, disaster relief, powercuts and hire companies.
Main features
- Frequency: 50 Hz
- Voltage: 400/230 V
- Power factor: 0.8 cos ϕ
- Phase: 3
Power rating
- Emergency standby power esp: 13.8 kVA
- Emergency standby power esp: 11.1 kW
- Continuous power cop: 11.8 kVA
- Continuous power cop: 9.4 kW
Single phase power rating
- Single phase maximum power: 7.5 kVA
- Single phase continuous power cop: 6.8 kVA
Rating definitions
Ratings definition (According to standard ISO8528 1:2005)
Engine specifications
- Engine brand: Honda
- Model: GX630
- [50hz] exhaust emission level: Stage V
- Engine cooling system: Air
- Displacement: 688 cm³
- Aspiration: Natural
- Operating speed-nominal: 3000 rpm
- Speed governor: Mechanical
- Fuel: Petrol
- Oil capacity: 1.9 l
- Starting system: Electric
- Electric circuit: 12 V
Alternator specifications
- Alternator: KWG
- Type: Brushless
- Class: H
- Ip protection: 54
- Poles: 2
- Frequency: 50 Hz
- Voltage: 400 V
- Voltage regulation system: Electronic
Dimensional data
- Length: 960 (L) mm
- Width: 641 (W) mm
- Height: 667 (H) mm
- Dry weight: 170 kg
- Fuel tank capacity: 24 l
Autonomy
- Fuel consumption at 75% of load: 4.23 l/h
- Fuel consumption at 100% of load: 5.64 l/h
- Running time at 75% of load: 5.67 h
- Running time at 100% of load: 4.26 h
Noise level
- Guaranteed noise level (lwa): 96 dB(A)
- Noise pressure level @ 7 m: 68 dB(A)
Control panels
GENSET CONTROL PANELS IP 54 (IPP)
Mounted on the genset and complete of: instrumentation, control, protection of the generating set and sockets.
Commands:
– Start selector switch with key: OFF – ON – START
Instrumentation:
– Hours-counter
– Voltmeter
Protections:
– Thermal Protection
– Isometer protection
– IP55 cover
– Oil Guard
Socket type
- Schuko 230v 16a ip54: 3
- 3p+n+t cee 400v 16a ip67: 1
- 3p+n+t cee 400v 32a ip67: 1