Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

Pramac GTW-30Y (22.8 kW) electric start soundproof diesel generator

Model: Pramac GTW-30Y. There are two main factors that the operators need to consider: • The type of site application • The electric input accepted by the Base Transceiver Station (BTS).

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Weight (kg) 987
Ingress protection rating IP 22
Material Galvanized steel
Dimensions 2110 x 1135 x 1304 mm
Tank capacity (L) 120
Power supply 230 V / 1 ph / 50 Hz
Power (kW) 22.8

Model: Pramac GTW-30Y

What are the factors to consider before choosing telecom generators?

There are two main factors that the operators need to consider:
• The type of site application
• The electric input accepted by the Base Transceiver Station (BTS)

Which versions of GTW are available?

In addition to the silent model, the GTW Series is designed in two optional versions : Super Silent and Long-running. The Super Silent range is specifically designed for urban areas where low noise emissions are required, while Long-running models are designed to increase running time, allowing to reduce refuelling frequency.

Power rating

  • Emergency standby power esp: 24.0 kVA
  • Emergency standby power esp: 24.0 kW
  • Prime power prp: 22.8 kVA
  • Prime power prp: 22.8 kW
  • Voltage: 230 V
  • Frequency: 50 Hz
  • Power factor: 1 cos ϕ
  • Phases: 1
  • Fuel: Diesel

Rating definitions

Ratings definition (ISO-8528-1)

ESP

  • Emergency Standby Power:

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.

PRP

  • Prime Power:

It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.

G2 class load acceptance in accordance with ISO 8528-5: Higher performance classes check upon request.

Gensets are compliant with EC mark which includes the following directives and standards and subsequent modification and intregation:

• 2006/42/CE Machinery safety

• 2014/30/UE Electromagnetic compatibility

• 2014/35/UE electrical equipment designed for use within certain voltage limits

• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC) – If applicable

• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2016/1628 EC) – If applicable

• ISO 8528 as applicable

• 2011/65 ROHS

• EN 12100, EN 13857, EN 60204 as referred into the ISO8528-13

Company with quality certification ISO 9001

Engine specifications

  • Engine brand: Yanmar
  • Model: 4TNV98-GPGE
  • Operation speed nominal: 1500 rpm
  • Engine cooling system: Water
  • Exhaust emission level: Non Emission Certified
  • Nr. of cylinder and disposition: 4 in line
  • Displacement: 3319 cm³
  • Aspiration: Natural Type
  • Speed governor: Mechanical
  • Gross engine power esp: 34.6 kWm
  • Gross engine power prp: 31.2 kWm
  • Fan power: 0.5 kWm
  • Fan air flow: 62 m³/min
  • Total oil capacity: 10.5 l
  • Total coolant capacity: 4.2 l
  • Fuel: Diesel
  • Specific fuel consumption 75% prp: 215 g/kWh
  • Starting system: Electric
  • Electric circuit: 12 V

Alternator specifications

  • Alternator brand: Pramac
  • Model: PB18G/4
  • Winding: Dedicated
  • Frequency: 50 Hz
  • Voltage: 230 V
  • Phases: 1
  • Power factor: 1 cos ϕ
  • Stand-by rating 27°c: 24 kVA
  • Continuous nominal rating 40°c: 22.8 kVA
  • Efficiency @ 100% of load: 86 %
  • Type: Brushless
  • Poles: 4
  • Voltage tolerance: 1 %
  • Class: H
  • Ip protection: 22
  • Cooling air: 0.095 m³/s

Genset equipment


STEEL SUPPORTING FRAME:

  • Sturdy Supporting Frame for moto-alternator and canopy.
  • Anti-vibration mounting properly sized.

BASEFRAME WITH INTEGRATED METAL FUEL TANK:

  • Metal fuel tank.
  • Filler neck.
  • Air breather (ventilation pipe).
  • Minimum fuel level sensor.
  • Fuel refiling point inside the canopy, protected by lockable doors.
  • Base forcabile by forklift.





EASY AND FAST MAINTENACE SERVICE:

  • Four large lateral doors for an easy maintenance & service.
  • Oil drainin pipe with cap.




ENGINE COMPLETE WITH:

  • Battery
  • Liquids (No Fuel)
  • Water temperature sensor
  • Lube oil pressure sensor


PROTECTIONS ANTITHEFT / VANDALISM:

  • Anti-theft screws.
  • Key Lockable door.
  • Anti-theft hinges.
  • Fuel refiling point inside the canopy, protected by key lockable doors.
  • Control panel positioned inside the canopy, protected by key lockable door.
  • Remote Control (available as option).
  • Door switches with alarm from control unit (available as option)





STACKABLE CANOPY:

  • Weatherproof enclosure made of galvanized sheet metal.
  • Noise attenuation thanks to Soundproofing material.
  • Four removable lifting points for easy Handling.
  • Control Panel inside the canopy, protected by door provided with window and lockable handle.
  • Front easy access power cable passage.
  • Lateral air inlet opening properly protected and soundproofed.
  • Exaust air outlet from the roof, trough wet section protected by rain flap.
  • Efficient residential silencer placed inside the canopy.
              • Baseframe: ​

              Automatic control panel (acp)

              Mounted on the genset, complete with Automatic control unit for monitoring, control and protection of the generating set, protected through door with lockable handle.

              DIGITAL INSTRUMENTATION

              • Generating set voltage (3 phases).
              • Mains voltage.
              • Generating set frequency.
              • Generating set current (3 phases).
              • Battery voltage.
              • Power (kVA – kW – kVAr).
              • Power factor Cos φ.
              • Hours-counter.
              • Engine speed r.p.m.
              • Fuel level (%).
              • Engine temperature.

              • Second part of the text: COMMANDS AND OTHERS Four operation modes: OFF – Manual starting – Automatic starting – Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Remote starting availability. Acoustic alarm. Battery charger. USB, RS232 and RS485 communication ports Settable PIN for protection level.
              • Third part of the text: PROTECTIONS WITH ALARM Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Four poles circuit breaker protection.
              • Part4: OTHERS PROTECTIONS Emergency stop button. Panel protected through door with lockable handle.

              Out put panel

              • Front easy access power cable passage:: √
              • Power cables connection to:: Power Terminals
              • Predisposed for remote control optional:: RGW

              Dimensional data

              • Length: 2110 (L) mm
              • Width: 1135 (W) mm
              • Height: 1304 (H) mm
              • Dry weight: 987 kg
              • Fuel tank material: Metal
              • Fuel tank capacity: 120 l

              Autonomy

              • Fuel consumption 75% prp: 5.16 l/h
              • Running time 75% prp: 23.26 h
              • Fuel consumption 100% prp: 6.95 l/h
              • Running time 100% prp: 17.27 h

              Installation data

              • Total air flow: 70 m³/min
              • Exhaust gas flow prp: 6.4 m³/min
              • Exhaust gas temperature: 540 °C

              Electrical data

              • Max current: 104 A
              • Nominal current: 99 A
              • Circuit breaker: 125 A

              Other configurations and options available:

              • Gtw / lr long running: √
              • Gtw / ss super silent: √
              • Gtw design combination: √
              • Monoblock protections and longer service options: √
              • Anti-theft options: √
              • Fuel tank options: √
              • Electrical options: √

              Gtw / lr long running:

              Designed in order to reduce the fuel refilling frequency, allowing a valuable cost reduction of the fuel transportation.

              Are available different Metal extended fuel tank single or double wall:


              Autonomy with eft:

              • Eft0 – running time 75% prp: 38.76 h
              • Eft1 – running time 75% prp: 96.90 h
              • Eft2 – running time 75% prp: 193.80 h
              • Eft3 – running time 75% prp: 290.70 h
              • Eft4 – running time 75% prp: 387.60 h

              Extended fuel tank eft0

              • Fuel tank capacity: 200 l
              • Length (genset): 2110 (L) mm
              • Width (genset): 1135 (W) mm
              • Height (genset): 1497 (H) mm
              • Extra – dry weight eft single wall:: 72 kg
              • Extra – dry weight eft double wall:: 132 kg

              Extended fuel tank eft1

              • Fuel tank capacity: 500 l
              • Length (genset): 2110 (L) mm
              • Width (genset): 1135 (W) mm
              • Height (genset): 1597 (H) mm
              • Extra – dry weight eft single wall:: 78 kg
              • Extra – dry weight eft double wall:: 161 kg

              Extended fuel tank eft2

              • Fuel tank capacity: 1000 l
              • Length (genset): 2110 (L) mm
              • Width (genset): 1135 (W) mm
              • Height (genset): 1861 (H) mm
              • Extra – dry weight eft single wall:: 128 kg
              • Extra – dry weight eft double wall:: 266 kg

              Extended fuel tank eft3

              • Fuel tank capacity: 1500 l
              • Length (genset): 2110 (L) mm
              • Width (genset): 1135 (W) mm
              • Height (genset): 2116 (H) mm
              • Extra – dry weight eft double wall:: 356 kg

              Extended fuel tank eft4

              • Fuel tank capacity: 2000 l
              • Length (genset): 2110 (L) mm
              • Width (genset): 1135 (W) mm
              • Height (genset): 2399 (H) mm
              • Extra – dry weight eft double wall:: 453 kg

              Gtw / ss- super silent

              Designed in order to reduce the noise level emissions.

              • Second part of the text: The Super Silent version is
                particularly suitable for BTS located near or inside the city centre or in any
                place where noise level emission restrictions are present. Modular design, allows to
                retrofit the sound attenuattion modules (SA), giving the possibility to
                transport genset and SA separately and to reassemble it on site.

              Gtw design combination

              GTW Series design offers several different versions thanks to the total Modularity-Product-Concept.

              Monoblock protections and longer service – options available:

              • Manual oil drain pump: MOP
              • Automatic lube oil: ALS
              • Water separator filter: WSP
              • Heavy duty filter: HDF
              • Pre-heating system: PHS
              • Windings total protection (alternator): WTP
              • Anti-condensation heater (alternator): ACH
              • Ingress protection (alternator): IP45

              Anti-theft – options available:

              • Vandal proof handle: VPH
              • Door switches: DSW

              Fuel tank – option available:

              • External fuel refiling: EFR
              • Automatic fuel pump: AFP
              • Electric fuel pump: EFP

              Electrical – option available:

              • Transfer switch: TWS
              • Terminal low potential: TLP
              • Remote gateway: RGW
              • Electronic engine governor: EEG
              • Surge suppressor: SSP
              • Engine analogue gauges: EAG
              • Fuel analog gauge: FAG
              • Low coolant level: LCL

              Datasheet (PDF)

              FAQ