Model: Pramac GSW-110P (Alt. P)
Main features
- Frequency: 50 Hz
- Voltage: 400 V
- Power factor: 0.8 cos ϕ
- Phase: 3
Power rating
- Emergency standby power esp: 110.00 kVA
- Emergency standby power esp: 88.00 kW
- Prime power prp: 101.70 kVA
- Prime power prp: 81.36 kW
Rating definitions
Ratings definition (ISO-8528-1)
ESP
- Emergency Standby Power:
It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.
PRP
- Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.
Engine specifications
- Engine brand: Perkins
- Model: 1104C-44TAG2
- [50hz] exhaust emission level: Stage II
- Engine cooling system: Water
- Nr. of cylinder and disposition: 4 in line
- Displacement: 4410 cm³
- Aspiration: Turbocharged
- Speed governor: Electronic
- Prime gross power prp: 93.6 kW
- Maximum gross power ltp esp: 103 kW
- Oil capacity: 8 l
- Lube oil consumption prp (max): 0.15 %
- Coolant capacity: 12.6 l
- Fuel: Diesel
- Specific fuel consumption 75% prp: 213.6 g/kWh
- Specific fuel consumption prp: 202.8 g/kWh
- Starting system: Electric
- Starting engine capability: 3 kW
- Electric circuit: 12 V
Engine equipment
- Starting system: Engine Equipment Standards The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1 Fuel system Rotary type pump Lube oil system Wet steel sump with filler and dipstick Filter • Fuel filter • Air filter • Oil filter Cooling system • Mounted radiator • Thermostatically-controlled system with belt driven coolant pump and pusher fan
Alternator specifications
- Alternator: Pramac
- Model: PB27C/4
- Voltage: 400 V
- Frequency: 50 Hz
- Power factor: 0.8 cos ϕ
- Poles: 4
- Type: Brushless
- Voltage tolerance: 1 %
- Efficiency @ 75% load: 91.5 %
- Class: H
- Ip protection: 22
Alternator equipment
- Mechanical structure: Mechanical structure
- Mechanical structure text: Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups.
- Voltage regulator: Voltage regulator
- Voltage regulator text: AVR – STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit.
- Windings / excitation system: Windings & Electrical performance
- Windings / excitation system text: All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.
- Insulation / impregnation: Insulation / Impregnation
- Insulation / impregnation text: The insulation system is class ‘H’. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components.
- Reference standards: Reference standards
- Reference standards text: Pramac Alternators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.
Genset equipment
BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH:
• Anti-vibration mountings properly sized
• Welded or Screwed support legs. (according to canopy size)
OIL DRAININ PIPE WITH CAP : • Oil draining facilities ENGINE COMPLETE WITH: • Battery • Liquids (no fuel)
CANOPY : • Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. • Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles; Detachable panels, with screws holes protected by rubber tap. • Control panel protection door provided with suitable window and lockable handle. • Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. • Single detachable lifting eye placed on the roof.
- Baseframe: PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: • Filler neck • Air breather (ventilation pipe) • Minimum fuel level sensor
- Text noise: SOUNDPROOF : • Noise attenuation thanks to soundproofing material • Efficient residential silencer placed inside the canopy
Dimensional data
- Length: 2398 (L) mm
- Width: 1000 (W) mm
- Height: 1532 (H) mm
- Dry weight: 1400 kg
- Fuel tank capacity: 209 l
- Fuel tank material: Plastic
Autonomy
- Fuel consumption @ 75% prp: 17.85 l/h
- Fuel consumption @ 100% prp: 22.60 l/h
- Running time 75% prp: 11.71 h
- Running time 100% prp: 9.25 h
Noise level
- Guaranteed noise level (lwa): 96 dB(A)
- Noise pressure level @ 7 m: 67 dB(A)
Installation data
- Total air flow: 202.45 m³/min
- Exhaust gas flow: 15.2 m³/min
- Exhaust gas temperature: 514 °C
Electrical data
- Battery capacity: 70 Ah
- Max current: 158.78 A
- Circuit breaker: 175 A
Control panel availability
- Automatic control panel: ACP
Acp – automatic control panel
Mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set protected through door with lockable door
INSTRUMENTATION DIGITAL
• Generating set voltage (3 phases)• Mains voltage
• Generating set frequency
• Generating set current (3 phases)
• Battery voltage• Power (kVA – kW – kVAr)• Power factor Cos• Hours-counter
• Engine speed r.p.m.• Fuel level (%)• Engine temperature (depending on model)
- Second part of the text: COMMANDS AND OTHERS • Four operation modes: OFF – Manual starting – Automatic starting – Automatic test • Pushbutton for forcing Mains contactor or Genset contactor • Push-buttons: start/stop, fault reset, up/down/page/enter selection • Remote starting availability • Acoustic alarm • Automatic battery charger • USB, RS232 and RS485 Communication ports • Settable PIN for protection level
- Third part of the text: PROTECTIONS WITH ALARM • Engine protections: low fuel level, low oil pressure, high engine temperature • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN • Engine protections: low fuel level, low oil pressure, high engine temperature • Genset protection: under/over voltage, overload, under/over battery voltage, battery charge failure
- Part4: OTHERS PROTECTIONS • Emergency stop button
Out put panel acp
- Plinth row for connection from acp to lts panel.: √
- Power cables connection to circuit breaker.: √
Optional features:
- To be ordered with equipment (when necessary): :
Engine supplements
- Coolant pre-heating system: PHS