Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

Pramac GRW100I/S5 soundproof diesel generator

Model: Pramac GRW100I/S5. Yes.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Weight (kg) 2210
Ingress protection rating IP 23
Dimensions 2800 x 1200 x 2035 mm
Noise level (dB) 66
Tank capacity (L) 540
Power supply 400/230 V / 3 ph / 50 Hz, 480/277 V / 3 ph / 60 Hz
Power (kW) 80, 91.8

Model: Pramac GRW100I/S5

Are there special solutions for the GRW Series?

Yes. The GRW Series is available in standard and super silent versions lowering noise emissions with the same generator performance.

What about the generator control system?

Innovative control system that allows work with 6 different operating modes in order to have the most efficient, reliable and suitable power supply on site.

What kind of application is the GRW Series ideal for?

The GRW series works across a wide variety of applications where a temporary power supply is needed, such as, events, constructions, working sites or city centers. These generators are the ideal solution for rental companies, thanks to their versatility, high efficiency and high structural resistance. They are easy to use and guarantee high degrees of protection, low noise emissions and easy access for maintenance.

Power rating

  • Emergency standby power esp: 104.3 kVA
  • Emergency standby power esp: 83.4 kW
  • Prime power prp: 100.0 kVA
  • Prime power prp: 80.0 kW
  • Frequency: 50 Hz
  • Voltage: 400/230 V
  • Phases: 3 №
  • Power factor: 0.8 cos ϕ
  • Fuel: Diesel
  • [50hz] exhaust emission level: Stage V
  • Version switchable [50/60hz]: YES

Rating definitions

Ratings definition (ISO-8528-1)

ESP

  • Emergency Standby Power:

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.

PRP

  • Prime Power:

It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.

G2 class load acceptance in accordance with ISO 8528-5: Higher performance classes check upon request.

Gensets are compliant with EC mark which includes the following directives and standards and subsequent modification and intregation:

• 2006/42/CE Machinery safety

• 2014/30/UE Electromagnetic compatibility

• 2014/35/UE electrical equipment designed for use within certain voltage limits

• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC) – If applicable

• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2016/1628 EC) – If applicable

• ISO 8528 as applicable

• 2011/65 ROHS

• EN 12100, EN 13857, EN 60204 as referred into the ISO8528-13

Company with quality certification ISO 9001

Power supply 60hz 480v three phase (with supplement dfs)

  • Frequency: 60 Hz
  • Voltage: 480/277 V
  • Phases: 3 №
  • Power factor: 0.8 cos ϕ
  • Emergency standby power esp: 114.7 kVA
  • Emergency standby power esp: 91.8 kW
  • Prime power prp: 114.7 kVA
  • Prime power prp: 91.8 kW
  • Max current: 138 A
  • Nominal current: 138 A

Engine specifications

  • Engine brand: FPT
  • Model: F36ETVP02.A94
  • Engine cooling system: Water
  • Nr. of cylinder and disposition: 4 in line
  • Displacement: 3600 cm³
  • Aspiration: Turbocharged aftercooled
  • Speed governor: Electronic
  • Oil capacity: 9.5 l
  • Lube oil consumption prp (max): 0.25 %
  • Coolant capacity: 5.5 l
  • Electric circuit: 12 V
  • Fuel: Diesel
  • Def consumption (as % of fuel consumption): 4.8 %
  • Version switchable [50/60hz]: YES
  • [50hz] operating speed-nominal: 1500 rpm
  • [50hz] exhaust emission level: Stage V
  • [50hz] specific fuel consumption 75% prp: 205 g/kWh
  • [50hz] specific fuel consumption 100% prp: 210 g/kWh
  • [60hz] operating speed-nominal: 1800 rpm
  • [60hz] specific fuel consumption 75% prp: 204 g/kWh
  • [60hz] specific fuel consumption 100% prp: 210 g/kWh

Alternator specifications

  • Alternator: Leroy Somer
  • Model: LSA 44.3 S5
  • Type: Brushless
  • Class: H
  • Ip protection: 23
  • Insulation protection systems: Protection System 2
  • Poles: 4
  • Winding leads: 12
  • Voltage regulation system: Electronic
  • Voltage tolerance: 1 %

Installation data

  • [50hz] cooling air: 129.40 m³/min
  • [50hz] exhaust gas flow prp: 6.7 m³/min
  • [50hz] exhaust gas temperature esp: 740 °C
  • [60hz] cooling air: 163.10 m³/min
  • [60hz] exhaust gas flow prp: 7.5 m³/min
  • [60hz] exhaust gas temperature esp: 740 °C

Electrical data

  • Battery voltage: 12 V
  • Battery capacity: 101 Ah
  • Circuit breaker: 160 A
  • Max current: 150 A

Genset equipment

​CANOPYCanopy painted made up of modular panels with 1000h+ tested salt spray resistant zinced metal sheet, with access doors on each side with high quality gaskets and lockable handles for easy maintenance and service.
BASE FRAMEHeavy duty base guarantees the highest standards of durability and resistance, painted using a high quality powder coating process (1000+h tested salt spray resistance).Fully bunded, able to retain 110% of all the sets fluids, the base frame is provided with integrated fork pockets and pull bar for easy maneuverability and site positioning.

LUBE OIL DRAIN PUMP Makes it easier to the engine oil change. FUEL VALVE (6 WAY) System designed for use the fuel from external tank and increase the autonomy of the generator. FUEL TANK Integrated metal fuel tank complete with double fuel refiling point (one each side). LEAK PROOF TRAY WITH DETECTOR SENSOR Fluid leak check in the leak proof tray.

  • Baseframe: ​ ​ SINGLE LIFTING POINT Access easy by rung and handle incorporated (available on both sides). MANUAL BATTERY SWITCH EARTH ROD Earth stock with cable fixed inside the genset. DOCS HOLDER Box intenal for documents, manuals and electrical drawings. HOT PARTS PROTECTIONS

Fuel tank – autonomy

  • Fuel tank location: Internal
  • Fuel tank material: Metal
  • Fuel tank capacity: 540 l
  • [50hz 400v] fuel consumption 75% prp: 16.65 l/h
  • [50hz 400v] running time 75% prp: 32.43 h
  • [50hz 400v] fuel consumption 100% prp: 22.56 l/h
  • [50hz 400v] running time 100% prp: 23.94 h
  • [60hz 480v] fuel consumption 75% prp: 19.50 l/h
  • [60hz 480v] running time 75% prp: 27.69 h
  • [60hz 480v] fuel consumption 100% prp: 26.26 l/h
  • [60hz 480v] running time 100% prp: 20.56 h

Def tank

  • Def tank capacity: 43 l
  • Def consumption (as % of fuel consumption): 4.8 %
  • [50hz 400v] def autonomy 75% prp: 53.82 h
  • [60hz 480v] def autonomy 75% prp: 45.94 h

Control panel – options available:

  • Automatic control panel: ACP
  • Modular parallel panel: MPP

Acp – automatic control panel

CONTROL SECTION:

  • Auto Mains Failure (AMF) function
  • Gen-set controller for single genset operating in standby or prime power modes
  • Full gen-set monitoring and protection
  • Detailed event and performance log with time and date
  • Emergency push button
  • Extra Instrumentation (analogue): Fuel level meter; Mechanical hour counter
  • Differential protection with internal switch
  • Battery charger.

    SOCKET SECTION:

    • Two wires facility for remote start/stop
    • Plug for auxiliary power supply
    • Socket Kit: Equipment and configurations available as a supplement.

    POWER SECTION:

    • It integrates 4 poles modular circuit breaker suitably rated with thermal and magnetic overloads.
    • Large and robust busbar with cables passage opening from the bottom for easy power cable connection.
    • Provided with safety switch to trip circuit breaker if operator open the power section door to operate on the bus bar.

    Mpp – modular parallel panel

    CONTROL SECTION:

    • Modular parallel panel allows the genset to work in parallel (up to 32 gen-sets)
    • Easy switching between parallel to mains or multiple genset applications
    • Full gen-set monitoring and protection
    • Detailed event and performance log with time and date
    • Colour display 7″ TFT with 800×480 px resolution
    • Wide range of communication and connection capabilities available
    • Emergency push button
    • Extra Instrumentation (analogue): Fuel level meter; Mechanical hour counter
    • Differential protection with internal switch
    • Battery charger.

    SOCKET SECTION:

    • Multi-pin connectors for paralle running.
    • Two wires facility for remote start/stop.
    • Plug for auxiliary power supply.
    • Socket Kit: Equipment and configurations available as a supplement.

    POWER SECTION

    • It integrates 4 poles motorized moulded case circuit breaker suitably rated with thermal and magnetic overloads
    • Large and robust busbar with cables passage opening from the bottom for easy power cable connection.
    • Provided with safety switch to trip circuit breaker if operator open the power section door to operate on the bus bar.

    Canopy version

    • Weatherproof Enclosure made of galvanized sheet metal allows to protect genset from corrosion and aggressive condition.
    • Enclousure soundproofed by means of washable and fireproof soundproofing material, allow to reach low noise level.
    • Exhaust residential silencer integrated inside the genset equipped with rain flap.
    • Enclousure equipped with bumpers to prevent damage during genset handling and transport.

    Dimensional data canopy version

    • Length: 2800 (L) mm
    • Width: 1200 (W) mm
    • Height: 2035 (H) mm

    Dimensional data canopy version

    • Weight: 2210 kg

    Noise level 50hz

    • Guaranteed noise level (lwa): 95 dB(A)
    • Noise pressure level @ 1 m: 77 dB(A)
    • Noise pressure level @ 7 m: 66 dB(A)

    Optional features:

    • To be ordered with equipment (when necessary): :

    Electrical option

    • Internal canopy lighting system with manual switch: ICL
    • Control section internal lighting (automatic with door switch): CLS
    • Dse2157 output (8) expansion module: ARM7
    • Dse890 mkii dsewebnet ® gateway 4g (gsm/ethernet antenna): RGW2
    • Engine analogue gauges (water temp / oil pressure): EAG
    • Insulation monitoring device (replace standard differential protection): IMD
    • Socket kit: SPK
    • Power lock: PWL
    • Bus bar arrangement: ERDF

    Mechanical option

    • Pre-heating system: PHS
    • Air inlet preheater: APH
    • Heavy-duty air filter: HDF
    • Exhaust spark arestor atex certified: ESA
    • Air shut-off valve: ASV
    • Galvanized sliding skid: GGS
    • Baseframe bumpers: BFB
    • Quick fit fuel and urea connectors – stage v: QFC – S5
    • Quick fit fuel and urea connectors inside the canopy – stagev: QFC1 – S5

    Datasheet (PDF)

    FAQ