Weight (kg) 7093
Ingress protection rating IP 23
Dimensions 3962 x 2000 x 2307 mm, 5750 x 2035 x 2678 mm, 6058 x 2444 x 2591 mm
Noise level (dB) 77
Power supply 400/230 V / 3 ph / 50 Hz
Power (kW) 597.2

Model: Pramac GDW825P/FNE

Which application is Higher Power Series suitable for?

The Higher Power Series is designed for emergency standby, prime power and load management applications: healthcare, data center, industry, construction, power production plant, among others.

Power rating

  • Emergency standby power esp: 821.4 kVA
  • Emergency standby power esp: 657.1 kW
  • Prime power prp: 746.5 kVA
  • Prime power prp: 597.2 kW
  • Voltage: 400/230 V
  • Frequency: 50 Hz
  • Power factor: 0.8 cos ϕ
  • Phases: 3
  • Fuel: Diesel

Rating definitions

Ratings definition (ISO-8528-1)

ESP

  • Emergency Standby Power:

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.

PRP

  • Prime Power:

It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.

G2 class load acceptance in accordance with ISO 8528-5: Higher performance classes check upon request.

Gensets are compliant with EC mark which includes the following directives and standards and subsequent modification and intregation:

• 2006/42/CE Machinery safety

• 2014/30/UE Electromagnetic compatibility

• 2014/35/UE electrical equipment designed for use within certain voltage limits

• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC) – If applicable

• 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2016/1628 EC) – If applicable

• ISO 8528 as applicable

• 2011/65 ROHS

• EN 12100, EN 13857, EN 60204 as referred into the ISO8528-13

Company with quality certification ISO 9001

Engine specifications

  • Engine brand: Perkins
  • Model: 4006-23TAG2A
  • Operation speed nominal: 1500 rpm
  • Engine cooling system: Water
  • Exhaust emission level: Unregulated
  • Nr. of cylinder and disposition: 6 in line
  • Displacement: 22921 cm³
  • Aspiration: Turbocharged aftercooled Type
  • Speed governor: Electronic
  • Gross engine power esp: 721 kWm
  • Gross engine power prp: 658 kWm
  • Total oil capacity: 113.4 l
  • Lube oil consumption prp (max): 0,5 % fuel consumption
  • Total coolant capacity: 210 l
  • Fuel: Diesel
  • Specific fuel consumption 100% esp: 210 g/kWh
  • Specific fuel consumption 75% prp: 211 g/kWh
  • Starting system: Electric
  • Electric circuit: 24 V

Radiator

  • Cooling fan: Mechanical Type
  • Cooling fan power: 30 kW
  • Cooling fan airflow rate: 870 m³/min

Alternator specifications

  • Alternator brand: Mecc Alte
  • Model: ECO40 VL4 C
  • Winding: Standard
  • Winding connections: Parallel Star Type
  • Frequency: 50 Hz
  • Voltage: 400 V
  • Phases: 3
  • Power factor: 0.8 cos ϕ
  • Stand-by rating 27°c: 825 kVA
  • Continuous nominal rating 40°c: 750 kVA
  • Efficiency @ 100% of load: 95.1 %
  • Type: Brushless
  • Poles: 4
  • Voltage tolerance: 0.5 %
  • Class: H
  • Ip protection: 23

Installation data

  • Total air flow: 984 m³/min
  • Exhaust gas flow prp: 180 m³/min
  • Exhaust gas temperature: 430 °C
  • Fuel consumption 75% prp: 125.59 l/h
  • Fuel consumption 100% prp: 163.38 l/h

Fuel tank – options available:

  • Pft running time 75% prp: 5.18 h
  • Mft-xs running time 75% prp: 3.98 h
  • Mft-s running time 75% prp: 7.96 h
  • Mft-m running time 75% prp: 15.92 h
  • Mft-l running time 75% prp: 31.85 h

Fuel tank – options available:

  • Plastic fuel tank: 8 Type
  • 8pft fuel tank capacity: 650 l
  • 8pft fuel tank location: Internal
  • Metal fuel tank: XS Type
  • Mft-xs fuel tank capacity: 500 l
  • Mft-xs fuel tank location: Internal
  • Metal fuel tank: S Type
  • Mft-s fuel tank capacity: 1000 l
  • Mft-s fuel tank location: Internal
  • Metal fuel tank: M Type
  • Mft-m fuel tank capacity: 2000 l
  • Mft-m fuel tank location: With sub-base
  • Mft-m extra height (for open/canopy versions): 218 mm
  • Mft-m extra height (for container versions): 305 mm
  • Mft-m extra weight: 703 kg
  • Metal fuel tank: L Type
  • Mft-l fuel tank capacity: 4000 l
  • Mft-l fuel tank location: With sub-base
  • Mft-l extra height (open/canopy versions): 718 mm
  • Mft-l extra weight: 1082 kg

Electrical data

  • Battery voltage: 24 V
  • Battery: 2 n
  • Battery capacity: 220 Ah
  • Genset voltage: 400/230 V
  • Frequency: 50 Hz
  • Phases: 3
  • Power factor: 0.8 cos ϕ
  • Max current: 1186 A
  • Nominal current: 1078 A
  • Circuit breaker: 1250 A

Control panel – options available:

  • Automatic control panel: ACP
  • Modular parallel panel: MPP

Acp – automatic control panel

  • Auto Mains Failure (AMF) function
  • Gen-set controller for single genset operating in standby or prime power modes
  • Full gen-set monitoring and protection
  • Detailed event and performance log with time and date
  • Wide range of remote control modules available as option
  • Wide range of I/O expansion modules available as option

Power supply by circuit breaker and/or terminal bus bar

Acp – power panel – breakers available:

  • Gcb1 – genset circuit breaker 3-pole: 1250 A
  • Gcb2 – genset circuit breaker 4-pole: 1250 A
  • Etb – external terminal board (with gcb): Standard

Mpp – modular parallel panel

  • Modular parallel panel allows the genset to work in parallel (up to 32 gen-sets)
  • Easy switching between parallel to mains or multiple genset applications
  • Full gen-set monitoring and protection
  • Detailed event and performance log with time and date
  • Wide range of communication and connection capabilities available

Power supply by circuit breaker and/or terminal bus bar

Mpp – power panel – breakers available:

  • Gmb1 – genset circuit breaker 3-pole motorized: 1250 A
  • Gmb2 – genset circuit breaker 4-pole motorized: 1250 A
  • Etb – external terminal board (with gmb): Standard

Open version

  • Baseframe made of welded steel profile
  • Anti-vibration mountings properly sized
  • Lifting points on the baseframe for handling by crane
  • Moving and rotating parts protection against accidental contact
  • Grounding point to connect all metal parts to ground

Dimensional data open version

  • Length: 3962 (L) mm
  • Width: 2000 (W) mm
  • Height: 2307 (H) mm

Dimensional data open version

  • Weight: 7093 kg

Canopy version

  • Weatherproof Enclosure made of galvanized sheet metal allows to protect genset from corrosion and aggressive condition
  • Soundproofed enclosure tanks to high quality soundproof material and residential silencer, allows to have low noise emission level
  • Big large lateral doors allows an easy service and maintenance operation
  • Doors equipped with key lockable handles
  • Baseframe made of welded steel profile
  • Anti-vibration mountings properly sized
  • Moving and rotating parts protection against accidental contact
  • Grounding point to connect all metal parts to ground
  • Lifting points for handling by crane

Dimensional data canopy version

  • Length: 5750 (L) mm
  • Width: 2035 (W) mm
  • Height: 2678 (H) mm

Dimensional data canopy version

  • Weight: 8085 kg

Noise level canopy version

  • Guaranteed noise level (lwa): 110 dB(A)
  • Noise pressure level @ 1 m: 89 dB(A)
  • Noise pressure level @ 7 m: 80 dB(A)
  • Noise pressure level @ 10 m: 77 dB(A)

Container version

  • Soundproofed Container adaptable to meet all your requirements and needs, equipped with residential silencer positioned inside or on the roof.
  • Sturdy structure similar to shipping containers: upper and lower corner castings, monolithic structure, walls and roof made of corrugated steel sheet.
  • Reinforced floor structure covered with teardrop patterned steel sheet
  • High resistance to the atmospheric agents.
  • Air inlet and exhaust openings air outlet for genset cooling.
  • Large lateral doors allows an easy service and maintenance operation.
  • Doors fixed by sturdy steel hinges equipped with lever bolt locks and panic bars.

Dimensional data container version

  • Length: 6058 (L) mm
  • Width: 2444 (W) mm
  • Height: 2591 (H) mm

Dimensional data container version

  • Weight: 11253 kg

Noise level container version

  • Noise pressure level @ 7 m: 77+/-3 dB(A)

Supplements available:

  • Manual battery switch: MBS
  • Double automatic fuel pump: DFP
  • Coolant pre-heating system: PHS
  • Heavy-duty air filter: HDF
  • Water separator filter: WSP
  • Alternator anti-condensation heater: ACH
  • Convention for safe container: CSC
  • Double electric start: DES
  • Upsized alternator: UAL

Datasheet (PDF)