O.ERRE GHOST-U 160 ACTIVE Local Heat Recovery Ventilator – 60 m³/h, Turbo 90 m³/h
The O.ERRE GHOST-U 160 ACTIVE is a high-performance local heat recovery ventilation unit, or heat recovery ventilator, that ensures controlled air exchange in a room without the need to install a central ventilation duct system.
The unit is installed through a Ø160 mm opening in an exterior wall and uses a high-efficiency ceramic heat exchanger. According to the manufacturer, the heat recovery efficiency reaches up to 93%.
The GHOST-U 160 ACTIVE is well-suited for single-family homes, apartments, bedrooms, living rooms, offices, and buildings undergoing renovation.
Airflow up to 90 m³/h
The GHOST-U 160 ACTIVE has a nominal maximum airflow of 60 m³/h, but the Turbo function allows the airflow to be temporarily increased to up to 90 m³/h.
This makes the Ø160 model suitable for situations where the airflow from a smaller Ø100 local heat recovery unit is insufficient.
Turbo mode can be used, for example, when there are more people in the room than usual or when more intensive air exchange is temporarily needed.
Heat recovery up to 93%
At the heart of the GHOST-U is a ceramic heat exchanger with a heat recovery efficiency of up to 93%.
According to the manufacturer, the heat exchanger in the Ø160 version is longer than usual— 150 mm compared to 100 mm —which improves average heat recovery efficiency by approximately 5%.
The purpose of heat recovery is to use the energy from the warm indoor air being extracted to raise the temperature of the fresh outdoor air. This allows the room to be ventilated with less heat loss than simply opening windows.
Very low power consumption—only 6.5 W
Despite a basic airflow of up to 60 m³/h, the GHOST-U 160 ACTIVE has a maximum electrical power consumption of just 6.5 W, according to the official technical documentation.
The device uses an electronically commutated brushless DC motor and ball bearings designed for long-term, energy-efficient operation.
Quiet Local Heat Recovery Unit
In the GHOST-U 160 design, the motor is located inside the wall behind the heat exchanger. The purpose of this design is to reduce fan noise entering the room.
According to the manufacturer’s latest official technical data sheet, the GHOST-U 160 ACTIVE has a maximum noise level of 25 dB(A) at a distance of 3 meters.
This makes the unit an attractive option for bedroom ventilation as well.
ACTIVE – Devices Work Together
One of the most important features of the ACTIVE version is the ability to connect multiple GHOST-U devices to each other via a cable to form a Master/Slave system.
Up to 16 GHOST-U devices can be connected to a single system. The role of each device is determined by DIP switches.
This allows you to create a local ventilation system in multiple rooms without traditional central ventilation ductwork.
For example, you can install units in bedrooms and the living room and have them operate in a coordinated manner.
4 operating speeds and night mode
The GHOST-U 160 ACTIVE offers four fan speed settings, one of which is a special night mode.
This allows you to reduce airflow when particularly quiet ventilation is desired in the room.
Integrated humidity sensor
The ACTIVE version features built-in humidity and twilight sensors.
These features allow you to use automatic operating modes and adjust the ventilation according to the conditions in the room.
A humidity sensor is particularly useful in rooms where humidity levels fluctuate throughout the day.
Control via Remote Control
The GHOST-U ACTIVE system can be controlled using a remote control with a display.
It’s important to be precise on the Pro Air product page: the latest English-language product information lists the display remote control as an optional accessory sold separately. Therefore, I would not write “remote control included” unless the set you are shipping specifically includes one.
No condensate drain required
One of the practical advantages of the GHOST-U is that, according to the manufacturer, the device does not require a separate condensate drain.
This simplifies installation, as there is no need to install separate condensate piping to the exterior wall.
Operates at temperatures as low as –30 °C
The operating temperature range for the GHOST-U 160 ACTIVE is:
–30 °C to +50 °C.
This is an important characteristic in Estonia’s climate.
At the same time, it is important to distinguish between the unit’s operating temperature and its heat recovery efficiency—at very low outdoor temperatures, the actual efficiency of heat recovery may decrease. The Estonian distributor also notes this.
IPX4 protection rating
The GHOST-U 160 ACTIVE has an IPX4 protection rating.
This means protection against water splashes in accordance with the IPX4 rating.
Washable filters
The device uses a double washable dust filter that is easily accessible for maintenance.
The LED indicator also signals when the filter needs to be cleaned. On the Ø160 model, the standard filters can be replaced with compatible filters available as optional accessories.
Also suitable for recessed installation
(with accessory)
The GHOST-U 160 ACTIVE can be mounted on the wall in the usual way or installed using the separate Built-in Kit, which allows for a more discreet recessed solution.
The minimum wall thickness for standard wall mounting is 250 mm, and 300 mm for the recessed version.
The duct included in the standard kit is 500 mm long; a 1000 mm version is available as an accessory.
GHOST-U 160 ACTIVE Technical Specifications
| Property | Data |
|---|---|
| Model | GHOST-U 160 ACTIVE |
| Product Code | 0028710 |
| Device type | local heat recovery unit |
| Airflow | up to 60 m³/h |
| Turbo airflow | up to 90 m³/h |
| Heat exchanger | ceramic |
| Maximum power | 6.5 W |
| Power Supply | 220–240 V / 50 Hz |
| Maximum pressure | 54 Pa |
| Noise Level | 25 dB(A) / 3 m |
| Operating temperature | –30…+50 °C |
| Weight | 5 kg |
| Humidity Sensor | Yes |
| Twilight Sensor | Yes |
| Operating Speeds | 4 |
| Master/Slave | Yes |
| Devices in the system | up to 16 |
| Connection | wired |
| Condensate Drain | Not required |
I checked these key specifications in O.ERRE’s latest official GHOST-U technical data sheet.
GHOST-U 160 ACTIVE or GHOST-U 100 ACTIVE?
The main difference lies in the airflow and the size of the installation opening.
GHOST-U 100 ACTIVE: Ø100 mm, up to 30 m³/h.
GHOST-U 160 ACTIVE: Ø160 mm, up to 60 m³/h + Turbo up to 90 m³/h.
Therefore, I would choose the GHOST-U 100 for a smaller room or a situation where a Ø160 mm duct opening cannot be installed.
The GHOST-U 160 is the better choice if you want greater air exchange, for example, in a bedroom, living room, or office.
Who is the GHOST-U 160 ACTIVE suitable for?
The GHOST-U 160 ACTIVE is a good choice if you want:
- ventilation with local heat recovery;
- reduce high CO₂ levels;
- improve bedroom ventilation;
- reduce the need to open windows;
- remove excess moisture;
- avoid the installation of central ventilation ductwork;
- combine multiple local heat recovery units into a single system;
- achieve a higher airflow rate than a standard local heat recovery unit.
The manufacturer has designed the GHOST-U for use in various rooms throughout the home, and synchronized units can be combined to form a more comprehensive ventilation system.
Frequently Asked Questions
What is the airflow rate of the GHOST-U 160 ACTIVE?
Up to 60 m³/h in standard mode and up to 90 m³/h with the Turbo function.
How efficient is heat recovery?
According to the manufacturer, the efficiency of a ceramic heat exchanger can reach up to 93%.
How much electricity does the device consume?
The official technical specifications list the maximum power consumption as 6.5 W.
Is the GHOST-U 160 ACTIVE suitable for a bedroom?
Yes. To reduce noise, the unit’s motor is located inside the wall behind the heat exchanger, and the official noise level is up to 25 dB(A) at a distance of 3 meters.
Can the units be connected to each other?
Yes. ACTIVE models use a wired connection, and up to 16 units can be connected in a single Master/Slave system.
Is a condensate drain required?
No. According to the manufacturer’s documentation, the GHOST-U does not require a separate condensate drain.
Is a remote control included in the package?
It depends on the package being sold. The latest product information lists the remote control with a display as a separately sold accessory.