Model: Pramac ES8000 400V 50Hz
LONG RUN ENERGY
A petrol generator designed specifically for intensive operations where performance power is demanded by professional user, over an extended period of time.
What kind of applications is the ES Series suitable for?
The ES Series ensure performance in a wide variety of applications, such as lighting, renovation works, gardening, disaster relief and hire companies.
Main features
- Frequency: 50 Hz
- Voltage: 400/230 V
- Power factor: 0.8 cos ϕ
- Phase: 3
Power rating
- Emergency standby power esp: 8.3 kVA
- Emergency standby power esp: 6.6 kW
- Continuous power cop: 7.0 kVA
- Continuous power cop: 5.6 kW
Single phase power rating
- Single phase maximum power: 4.0 kVA
- Single phase continuous power cop: 3.7 kVA
Rating definitions
Ratings definition (ISO-8528)
MAX
- Maximum Power:
It is defined as the power given by multiplying the current and voltage that the generating set is capable of delivering for at least 5 min. Prescribed output voltage shall be within ±10 % of the rated voltage and prescribed output frequency shall be within ±8 % of the rated frequency.
COP
- Continuos Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously for an unlimited number of hours, with the maintenance intervals and procedure being carried out as prescribed by the manufacturers.
Engine specifications
- Engine brand: Honda
- Model: GX390 Recoil
- Engine cooling system: Air
- Displacement: 389 cm³
- Aspiration: Natural
- Operating speed-nominal: 3000 rpm
- Speed governor: Mechanical
- Fuel: Petrol
- Oil capacity: 1.1 l
- Starting system: Recoil
Alternator specifications
- Alternator: NSM
- Type: Brushes
- Class: H
- Ip protection: 23
- Poles: 2
- Frequency: 50 Hz
- Voltage: 400 V
- Voltage regulation system: Compound
- Voltage tolerance: 6 %
Dimensional data
- Length: 729 (L) mm
- Width: 500 (W) mm
- Height: 536 (H) mm
- Dry weight: 81 kg
- Fuel tank capacity: 11 l
Autonomy
- Fuel consumption at 75% of load: 2.15 l/h
- Fuel consumption at 100% of load: 2.86 l/h
- Running time at 75% of load: 5.12 h
- Running time at 100% of load: 3.85 h
Noise level
- Guaranteed noise level (lwa): 97 dB(A)
- Noise pressure level @ 7 m: 69 dB(A)
Control panels
GENSET CONTROL
COMMANDS:
- Selector switch: OFF – ON
- Starting systems: Recoil
- Fuel Cock
PROTECTIONS STANDARD:
- Thermal protection
- Oil Guard
Socket type
- Schuko 230v 16a ip54: 1
- 2p+t cee 230v 16a ip44: 1
- 3p+n+t cee 400v 16a ip44: 1
Supplements control (available when ordered)
- Ascodif: Electrical box DPP + HM Extra Protection with: • Differential protection 30mA • Circuit breaker • Hourmeter