Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-AM 45 data logger for temperature and humidity

Data Logger for Temperature and Humidity with Beaufort scale / Wind direction display / Measuring range 0.3 … 45.0 m/s / 0.9 … 147 ft/s / Data memory for 960 measured values ​​/ Software for transferring the measured values ​​/ Velocity and volume flow measurement. The data logger for temperature and humidity determines the wind speed via an impeller with a diameter of 65 mm / 2.5".

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Andmemälu maht 960 väärtust
Anduri tüüp Tiivikandur
Ekraan LCD
Eraldusvõime Õhuvooluhulk: 0,1 m³/min, Õhuvooluhulk: 1 m³/min, Õhuvooluhulk: 10 m³/min, Õhuvooluhulk: 100 m³/min, Suhteline õhuniiskus: 0,1 % RH, Temperatuur: 0,1 °C, Temperatuur: 0,18 °F, Tuule suund: 1 °, Tuulekiirus: 0,01 km/h, Tuulekiirus: 0,01 knots, Tuulekiirus: 0,01 m/s, Tuulekiirus: 0,01 mph, Tuulekiirus: 0,1 ft/min
Weight (kg) 0.22
Kaitseklass IP20
Liides Micro-USB
Mõõtefunktsioonid Keskmine väärtus, Maksimaalväärtus, Minimaalväärtus, Näidu hoidmine
Mõõdetav suurus Õhuvooluhulk, Suhteline õhuniiskus, Temperatuur, Tuule suund, Tuulekiirus, Vooluhulk
Dimensions 194 x 70 x 38 mm
Toiteallikas Patarei
Töötingimused (% RH) 40 - 80
Töötingimused (°C) 0 - 50

Data Logger for Temperature and Humidity with Beaufort scale / Wind direction display / Measuring range 0.3 … 45.0 m/s / 0.9 … 147 ft/s / Data memory for 960 measured values ​​/ Software for transferring the measured values ​​/ Velocity and volume flow measurement

The data logger for temperature and humidity determines the wind speed via an impeller with a diameter of 65 mm / 2.5″. The anemometer can reliably determine the speed in a measuring range of 0.3 … 45.0 m/s / 0.9 … 147 ft/s. In addition to the speed measurement with the anemometer, a volume flow measurement can also be carried out. In addition to the normal measured value display on the anemometer, a Beaufort scale is stored. The wind strength level is displayed directly on the Beaufort scale on the anemometer.

Depending on the orientation of the impeller, the data logger for temperature and humidity can also be used to determine the wind direction. This is made possible by the anemometer’s built-in gyroscope. At the same time, the current ambient temperature between 0 … 45 °C / 32 … 113 °F is displayed on the anemometer. For optimal alignment, the telescopic arm of the anemometer can be extended up to 315 mm / 12.4″.

With the integrated data memory of 960 measured values, individual measured values ​​can be saved on the data logger for temperature and humidity at the touch of a button. All measured values ​​can then be transferred to a PC via the micro USB data interface. With the software in the PCE download portal, the values ​​measured by the anemometer can be analyzed and further processed. Live measurement on the PC is also possible with the anemometer and the software.

Highlights

  • Battery operation for mobile use
  • Telescopic probe with a length of 270 … 540 mm / 10.63 … 21.26“
  • Impeller opening of 65 mm / 2.5″
  • Velocity and volume flow measurement
  • Measuring range 0.3 … 45.0 m/s / 0.9 … 147 ft/s
  • Backlit LC display

Technical specifications

  • Speed — Measuring range: 0,3 … 45 m/s
  • Speed — Resolution: 0.01 m/s
  • Speed — Accuracy: ±3 % of Rd ±0.1 m/s
  • Speed — Measuring range: 60 … 8800 ft/min
  • Speed — Resolution: 0.1 ft/min
  • Speed — Accuracy: ±3 % of Rd ±20 ft/min
  • Speed — Measuring range: 0,6 … 88 knots
  • Speed — Resolution: 0.01 knots
  • Speed — Accuracy: ±3 % of Rd ±0.2 knots
  • Speed — Measuring range: 1 … 140 km/h
  • Speed — Resolution: 0.01 km/h
  • Speed — Accuracy: ±3 % of Rd ±0.4 km/h
  • Speed — Measuring range: 0,7 … 100 mph
  • Speed — Resolution: 0.01 mph
  • Speed — Accuracy: ±3 % of Rd ±0.2 mph
  • Volume flow — Measuring range: 0 … 999,9 m³/min
  • Volume flow — Resolution: 0,1 m³/min
  • Volume flow — Accuracy: calculated from wind speed and area
  • Volume flow — Measuring range: 1000 … 9999 m³/min
  • Volume flow — Resolution: 1 m³/min
  • Volume flow — Measuring range: 10000 … 99990 m³/min
  • Volume flow — Resolution: 10 m³/min
  • Volume flow — Measuring range: 100000 … 999900 m³/min
  • Volume flow — Resolution: 100 m³/min
  • Wind direction — Measuring range: 0 … 360 °
  • Wind direction — Resolution: 1 °
  • Relative humidity — Measuring range: 10 … 90 % RH
  • Relative humidity — Resolution: 0,1 % RH
  • Relative humidity — Accuracy: ±5 % RH
  • Temperature — Measuring range: 0 … 45 °C
  • Temperature — Resolution: 0,1 °C
  • Temperature — Accuracy: ±1.0 °C
  • Temperature — Measuring range: 32 … 113 °F
  • Temperature — Resolution: 0,18 °F
  • Temperature — Accuracy: ±1.8 °F
  • Sensor — Battery: type Vane
  • Sensor: Dimension Opening: Ø65 mm, length: 270 … 545 mm, width: 75 mm, height: 36 mm
  • General technical data — Measuring functions: HOLD, MAX, MIN, AVG
  • General technical data — Display type: LCD with backlight
  • General technical data — Display size: 3 Inch
  • General technical data — Display refresh rate: 3 x per second
  • General technical data — Storage capacity: 960 Values
  • General technical data — Interface: Micro-USB
  • General technical data: Automatic power-off 5 min
  • General technical data — Housing: ABS (acrylonitrile-butadiene-styrene copolymers)
  • General technical data — Menu language: English, English (GB)
  • General technical data — Protection class (device): IP20
  • General technical data — (Rechargeable) battery: 4 x 1,5 V AAA battery , Alkali-manganese
  • General technical data — Capacity: 1200 mAh
  • General technical data — Operating conditions: 0 … 50 °C , 40 … 80 % RH
  • General technical data — Storage conditions: -20 … 60 °C , 0 … 80 % RH
  • General technical data — Dimensions: ( L x W x H )194 x 70 x 38 mm
  • General technical data — Weight: 220 g

Delivery scope

  • 1 x Data Logger for Temperature and Humidity PCE-AM 45
  • 1 x Micro USB cable
  • 1 x Transport case
  • 4 x 1.5 V AAA batteries
  • 1 x Instruction manual

Documents

FAQ