Kuma tee 4, Peetri, Estonia
Mon–Fri 9:00 a.m.–5:00 p.m.

PCE Instruments PCE-ADL 11 wind speed meter

PCE-ADL 11A Wind speed meterwind gauge for different units (m / s, knots, km / h) / Data logger function / Measured value memory for up to 60,000 values ​​/ USB interface / Software for evaluation / Configurable via PC software / Threaded hole for mounting. The wind speed meter PCE-ADL 11 is a data logger for wind speeds.

  • In stock
Free shipping For orders over €250
14-Day Return Policy Worry-Free Right to Purchase
Safe Payment
Andmemälu maht 60000 väärtust
Andmemälu tüüp Sisemälu
Anduri tüüp Tiivikandur
Eraldusvõime Tuulekiirus: 0,01 m/s, Tuulekiirus: 0,1 km/h, Tuulekiirus: 0,1 knots, Tuulekiirus: 0,1 mph, Tuulekiirus: 1 ft/min
Weight (kg) 0.06
Kaitseklass IP42
Liides USB
Mõõtefunktsioonid Keskmine väärtus, Maksimaalväärtus, Minimaalväärtus
Mõõteintervall 3 s ... 12 h, Salvestusintervall 3 s ... 12 h
Mõõdetav suurus Tuulekiirus
Dimensions 140 x 30 x 25 mm
Reageerimisaeg Tiivik reageerib väikestele voolukiirustele
Toiteallikas Patarei
Töötingimused (% RH) 0 - 80
Töötingimused (°C) 0 - 50

PCE-ADL 11A Wind speed meterwind gauge for different units (m / s, knots, km / h) / Data logger function / Measured value memory for up to 60,000 values ​​/ USB interface / Software for evaluation / Configurable via PC software / Threaded hole for mounting

The wind speed meter PCE-ADL 11 is a data logger for wind speeds. The configuration on the wind measuring device is carried out via the supplied software and provides multiple settings for measurement.The wind speed meter measures various parameters. These include m / sec, km / h, knots, mph and ft / min. In addition to the measurement parameters, the measurement intervals can be set on the software by the wind measuring device. The data logger function accommodates 60,000 measured values. After completing the series of measurements, the data from the wind gauge can be read out on the computer via the software. The measurement results are displayed as either graphically as a curve or in tabular form.

The impeller installed on the wind gauge already responds to low flow velocities. In this case, the wind speed meter can be fixed by means of a mounting device. There is a threaded hole on the bottom of the wind gauge, so you can attach the unit firmly to the mounting bracket.

Highlights

  • Threaded hole on the device
  • Configuration via the software
  • Easy to use
  • Direct-reacting, smooth-running impeller
  • Various measuring units selectable
  • Evaluation on the PC (graphic representation)
  • Alarm when limit value exceeded
  • Measurement memory for up to 60,000 values

Technical specifications

  • Speed — Measuring range: 1,2 … 30 m/s
  • Speed — Resolution: 0.01 m/s
  • Speed — Accuracy: ±(3 % +0.20 m/s)
  • Speed — Measuring range: 4,3 … 108 km/h
  • Speed — Resolution: 0.1 km/h
  • Speed — Accuracy: ±(3% +1.0 km/h)
  • Speed — Measuring range: 2,33 … 58,32 knots
  • Speed — Resolution: 0.1 knots
  • Speed — Accuracy: ±(3 % +0.4 knots)
  • Speed — Measuring range: 2,69 … 67,2 mph
  • Speed — Resolution: 0.1 mph
  • Speed — Accuracy: ±(3 % +0.4 mph)
  • Speed — Measuring range: 236 … 5906 ft/min
  • Speed — Resolution: 1 ft/min
  • Speed — Accuracy: ±(3 % +40 ft/m)
  • General technical data — Measuring functions: MIN, MAX, AVG
  • Storage medium Internal memory — Storage capacity: 60000 Values
  • Storage medium Internal memory: Memory information The stored data is read out on the computer using the software.
  • Storage medium Internal memory — Storage interval from: 3 s
  • Storage medium Internal memory — Storage interval to: 12 h
  • Storage medium Internal memory — Interface: USB
  • Storage medium Internal memory — Other dimensions: Vane Ø157 x 45 mm
  • Alarm optical, Acoustic — Protection class (device): IP42
  • Alarm optical, Acoustic — (Rechargeable) battery: 1 x 3,6 V 1/2 AA (LS 14250) , Lithium thionyl chloride
  • Alarm optical, Acoustic — Capacity: 1200 mAh
  • Alarm optical, Acoustic — Operating conditions: 0 … 50 °C , 0 … 80 % RH
  • Alarm optical, Acoustic — Storage conditions: 0 … 50 °C , 0 … 80 % RH
  • Alarm optical, Acoustic — Dimensions: ( L x W x H )140 x 30 x 25 mm
  • Alarm optical, Acoustic — Weight: 60 g

Delivery scope

  • 1 x Wind Speed Meter / Wind Speed Meters for all applications PCE-ADL 11
  • 1 x Mounting device
  • 1 x Software
  • 1 x Impeller
  • 1 x 3.6V lithium thionyl chloride battery
  • 1 x User manual

Documents