{"id":55959,"date":"2026-11-24T10:27:13","date_gmt":"2026-11-24T10:27:13","guid":{"rendered":"https:\/\/proair.ee\/toode\/pramac-gdw900b-fne-ual-400-230-v-3-ph-elektristarteriga-diiselgeneraator\/"},"modified":"2026-11-24T14:08:55","modified_gmt":"2026-11-24T14:08:55","slug":"pramac-gdw900b-fne-ual-400-230-v-3-ph-elektristarteriga-diiselgeneraator","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pramac-gdw900b-fne-ual-400-230-v-3-ph-elektristarteriga-diiselgeneraator\/","title":{"rendered":"Pramac GDW900B\/FNE UAL (400\/230 V \/ 3 ph) electric start diesel generator"},"content":{"rendered":"<p>Model: Pramac GDW900B\/FNE UAL<\/p>\n<h3>Which application is Higher Power Series suitable for?<\/h3>\n<p>The Higher Power Series is designed for emergency standby, prime power and load management applications: healthcare, data center, industry, construction, power production plant, among others.<\/p>\n<h3>Power rating<\/h3>\n<ul>\n<li>Emergency standby power esp: 910.2 kVA<\/li>\n<li>Emergency standby power esp: 728.2 kW<\/li>\n<li>Prime power prp: 829.5 kVA<\/li>\n<li>Prime power prp: 663.6 kW<\/li>\n<li>Voltage: 400\/230 V<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Phases: 3<\/li>\n<li>Fuel: Diesel<\/li>\n<\/ul>\n<h3>Power rating dcp<\/h3>\n<ul>\n<li>Data center power dcp: 829 kVA<\/li>\n<li>Data center power dcp: 663 kW<\/li>\n<li>Voltage: 400\/230 V<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Phase: 3<\/li>\n<li>Fuel: Diesel<\/li>\n<\/ul>\n<h3>Engine specifications<\/h3>\n<ul>\n<li>Engine brand: Baudouin<\/li>\n<li>Model: 12M26 G900\/5<\/li>\n<li>Operation speed nominal: 1500 rpm<\/li>\n<li>Engine cooling system: Water<\/li>\n<li>Exhaust emission level: Non Emission Certified<\/li>\n<li>Nr. of cylinder and disposition: 12 V angle<\/li>\n<li>Displacement: 31800 cm\u00b3<\/li>\n<li>Aspiration: Turbocharged aftercooled Type<\/li>\n<li>Speed governor: Electronic<\/li>\n<li>Gross engine power esp: 793 kWm<\/li>\n<li>Gross engine power prp: 725 kWm<\/li>\n<li>Gross data center power dcp: 725 kWm<\/li>\n<li>Total oil capacity: 109 l<\/li>\n<li>Lube oil consumption prp (max): 0.3 % fuel consumption<\/li>\n<li>Total coolant capacity: 204 l<\/li>\n<li>Fuel: Diesel<\/li>\n<li>Specific fuel consumption 100% esp: 202.1 g\/kWh<\/li>\n<li>Specific fuel consumption 75% prp: 205.6 g\/kWh<\/li>\n<li>Starting system: Electric<\/li>\n<li>Electric circuit: 24 V<\/li>\n<\/ul>\n<h3>Radiator<\/h3>\n<ul>\n<li>Cooling fan: Mechanical Type<\/li>\n<li>Cooling fan power: 26.5 kW<\/li>\n<li>Cooling fan airflow rate: 840 m\u00b3\/min<\/li>\n<\/ul>\n<h3>Alternator specifications<\/h3>\n<ul>\n<li>Alternator brand: Leroy Somer<\/li>\n<li>Model: LSA49.3 L9<\/li>\n<li>Winding: Standard<\/li>\n<li>Winding connections: Star Type<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Voltage: 400 V<\/li>\n<li>Phases: 3<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Stand-by rating 27\u00b0c: 1020 kVA<\/li>\n<li>Continuous nominal rating 40\u00b0c: 910 kVA<\/li>\n<li>Efficiency @ 100% of load: 95 %<\/li>\n<li>Type: Brushless<\/li>\n<li>Poles: 4<\/li>\n<li>Voltage tolerance: 0.5 %<\/li>\n<li>Class: H<\/li>\n<li>Ip protection: 23<\/li>\n<\/ul>\n<h3>Installation data<\/h3>\n<ul>\n<li>Total air flow: 956 m\u00b3\/min<\/li>\n<li>Exhaust gas flow prp: 137.9 m\u00b3\/min<\/li>\n<li>Exhaust gas temperature: 550 \u00b0C<\/li>\n<\/ul>\n<h3>Fuel tank &#8211; options available:<\/h3>\n<ul>\n<li>Plastic fuel tank: 8 Type<\/li>\n<li>8pft  fuel tank capacity: 650 l<\/li>\n<li>8pft fuel tank location: Internal<\/li>\n<li>Metal fuel tank: XS Type<\/li>\n<li>Mft-xs  fuel tank capacity: 500 l<\/li>\n<li>Mft-xs fuel tank location: Internal<\/li>\n<li>Metal fuel tank: S Type<\/li>\n<li>Mft-s  fuel tank capacity: 1000 l<\/li>\n<li>Mft-s fuel tank location: Internal<\/li>\n<li>Metal fuel tank: M Type<\/li>\n<li>Mft-m  fuel tank capacity: 2000 l<\/li>\n<li>Mft-m fuel tank location: With sub-base<\/li>\n<li>Mft-m extra height  (for open\/canopy versions): 218 mm<\/li>\n<li>Mft-m extra height  (for container versions): 305 mm<\/li>\n<li>Mft-m  extra weight: 703 kg<\/li>\n<li>Metal fuel tank: L Type<\/li>\n<li>Mft-l  fuel tank capacity: 4000 l<\/li>\n<li>Mft-l fuel tank location: With sub-base<\/li>\n<li>Mft-l extra height (open\/canopy versions): 718 mm<\/li>\n<li>Mft-l  extra weight: 1082 kg<\/li>\n<\/ul>\n<h3>Electrical data<\/h3>\n<ul>\n<li>Battery voltage: 24 V<\/li>\n<li>Battery: 2 n<\/li>\n<li>Battery capacity: 220 Ah<\/li>\n<li>Genset voltage: 400\/230 V<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Phases: 3<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Max current: 1314 A<\/li>\n<li>Nominal current: 1197 A<\/li>\n<li>Circuit breaker: 1600 A<\/li>\n<\/ul>\n<h3>Acp &#8211; power panel &#8211; breakers available:<\/h3>\n<ul>\n<li>Gcb1 &#8211; genset circuit breaker 3-pole: 1600 A<\/li>\n<li>Gcb2 &#8211; genset circuit breaker 4-pole: 1600 A<\/li>\n<li>Etb &#8211; external terminal board (with gcb): Standard<\/li>\n<\/ul>\n<h3>Mpp &#8211; power panel &#8211; breakers available:<\/h3>\n<ul>\n<li>Gmb1 &#8211; genset circuit breaker 3-pole motorized: 1600 A<\/li>\n<li>Gmb2 &#8211; genset circuit breaker 4-pole motorized: 1600 A<\/li>\n<li>Etb &#8211; external terminal board (with gmb): Standard<\/li>\n<\/ul>\n<h3>Dimensional data open version<\/h3>\n<ul>\n<li>Length: 3962 (L) mm<\/li>\n<li>Width: 2000 (W) mm<\/li>\n<li>Height: 2160 (H) mm<\/li>\n<\/ul>\n<h3>Dimensional data open version<\/h3>\n<ul>\n<li>Weight: 7834 kg<\/li>\n<\/ul>\n<h3>Dimensional data canopy version<\/h3>\n<ul>\n<li>Length: 5750 (L) mm<\/li>\n<li>Width: 2035 (W) mm<\/li>\n<li>Height: 2678 (H) mm<\/li>\n<\/ul>\n<h3>Dimensional data canopy version<\/h3>\n<ul>\n<li>Weight: 8826 kg<\/li>\n<\/ul>\n<h3>Noise level canopy version<\/h3>\n<ul>\n<li>Guaranteed noise level (lwa): 84 dB(A)<\/li>\n<li>Noise pressure level @ 1 m: 63 dB(A)<\/li>\n<li>Noise pressure level @ 7 m: 54 dB(A)<\/li>\n<li>Noise pressure level @ 10 m: 51 dB(A)<\/li>\n<\/ul>\n<h3>Dimensional data container version<\/h3>\n<ul>\n<li>Length: 6058 (L) mm<\/li>\n<li>Width: 2444 (W) mm<\/li>\n<li>Height: 2591 (H) mm<\/li>\n<\/ul>\n<h3>Dimensional data container version<\/h3>\n<ul>\n<li>Weight: 11994 kg<\/li>\n<\/ul>\n<h3>Noise level container version<\/h3>\n<ul>\n<li>Noise pressure level @ 7 m: 77+\/-3 dB(A)<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.pramac.com\/api\/v1\/get-pdf-product-card?product_code=198107&amp;url=https%3A%2F%2Fwww.pramac.com%2Fproduct-card%3FprodKrid%3D198107%26folder%3D369%26charType%3D3%26brandKrid%3D1%26kLang%3Den_GB%26marketKid%3D252\">Datasheet (PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model: Pramac GDW900B\/FNE UAL. The Higher Power Series is designed for emergency standby, prime power and load management applications: healthcare, data center, industry, construction, power production plant, among others.<\/p>\n","protected":false},"featured_media":54454,"template":"","meta":{"_acf_changed":false},"product_brand":[8760],"product_cat":[1033],"product_tag":[],"class_list":["post-55959","product","type-product","status-publish","has-post-thumbnail","product_brand-pramac","product_cat-industrial-generators","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/55959","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/54454"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=55959"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=55959"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=55959"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=55959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}