{"id":54649,"date":"2026-11-24T09:36:28","date_gmt":"2026-11-24T09:36:28","guid":{"rendered":"https:\/\/proair.ee\/toode\/pramac-gbw15p-10-17-kw-murasummutusega-diiselgeneraator\/"},"modified":"2026-11-24T11:00:40","modified_gmt":"2026-11-24T11:00:40","slug":"pramac-gbw15p-10-17-kw-murasummutusega-diiselgeneraator","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pramac-gbw15p-10-17-kw-murasummutusega-diiselgeneraator\/","title":{"rendered":"Pramac GBW15P (10.17 kW) soundproof diesel generator"},"content":{"rendered":"<p>Model: Pramac GBW15P<\/p>\n<h3>Main features<\/h3>\n<ul>\n<li>Frequency: 50 Hz<\/li>\n<li>Voltage: 230 V<\/li>\n<li>Power factor: 1 cos \u03d5<\/li>\n<li>Phase: 1<\/li>\n<\/ul>\n<h3>Power rating<\/h3>\n<ul>\n<li>Emergency standby power esp: 11.27 kVA<\/li>\n<li>Emergency standby power esp: 11.27 kW<\/li>\n<li>Prime power prp: 10.17 kVA<\/li>\n<li>Prime power prp: 10.17 kW<\/li>\n<\/ul>\n<h3>Rating definitions<\/h3>\n<p><b>Ratings definition (ISO-8528-1)<\/b><\/p>\n<p>ESP<\/p>\n<ul>\n<li>Emergency Standby Power:<\/li>\n<\/ul>\n<p>It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.<\/p>\n<p>PRP<\/p>\n<ul>\n<li>Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.<\/li>\n<\/ul>\n<h3>Engine specifications<\/h3>\n<ul>\n<li>Engine brand: Perkins<\/li>\n<li>Model: 403D-15G<\/li>\n<li>[50hz] exhaust emission level: Unregulated<\/li>\n<li>Engine cooling system: Water<\/li>\n<li>Nr. of cylinder and disposition: 3 in line<\/li>\n<li>Displacement: 1496 cm\u00b3<\/li>\n<li>Aspiration: Natural<\/li>\n<li>Speed governor: Mechanical<\/li>\n<li>Prime gross power prp: 12.2 kW<\/li>\n<li>Maximum gross power ltp esp: 13.5 kW<\/li>\n<li>Oil capacity: 6 l<\/li>\n<li>Coolant capacity: 6 l<\/li>\n<li>Fuel: Diesel<\/li>\n<li>Specific fuel consumption 75% prp: 252 g\/kWh<\/li>\n<li>Specific fuel consumption prp: 248 g\/kWh<\/li>\n<li>Starting system: Electric<\/li>\n<li>Starting engine capability: 2 kW<\/li>\n<li>Electric circuit: 12 V<\/li>\n<\/ul>\n<h3>Engine equipment<\/h3>\n<ul>\n<li>Starting system: Engine Equipment Standards The above ratings represent the engine performance capabilities to conditions specified in ISO 8528\/1, ISO 3046\/1:1986, BS 5514\/1 Fuel system Rotary type pump Lube oil system Wet steel sump with filler and dipstick Filter \u2022 Fuel filter \u2022 Air filter \u2022 Oil filter Cooling system \u2022 Mounted radiator \u2022 Thermostatically-controlled system with belt driven coolant pump and pusher fan<\/li>\n<\/ul>\n<h3>Alternator specifications<\/h3>\n<ul>\n<li>Alternator: Linz<\/li>\n<li>Model: E1S13ME<\/li>\n<li>Voltage: 230 V<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Power factor: 1 cos \u03d5<\/li>\n<li>Poles: 4<\/li>\n<li>Type: Brushes<\/li>\n<li>Voltage tolerance: 1.5 %<\/li>\n<li>Efficiency @ 75% load: 85.22 %<\/li>\n<li>Class: H<\/li>\n<li>Ip protection: 21<\/li>\n<\/ul>\n<h3>Alternator equipment<\/h3>\n<ul>\n<li>Mechanical structure: Mechanical structure<\/li>\n<li>Mechanical structure text: Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups.<\/li>\n<li>Voltage regulator text: Output voltage wave form: The low harmonic content (&lt;5%) allows supplying any type of load, including distorting loads. Overload: 10% overload for one hour every 6 hours is normally accepted. Short overloads can be very high (three times the rated current).<\/li>\n<\/ul>\n<h3>Genset equipment<\/h3>\n<p><strong>BASE FRAME MADE OF WELDER STEEL PROFILE, COMPLETE WITH:<\/strong><\/p>\n<p><strong><br \/><\/strong><\/p>\n<p>\u2022 Anti-vibration mountings properly sized<\/p>\n<p>\u2022 Visual fuel level indicator<\/p>\n<p>\u2022 Integrated support legs.<\/p>\n<p>OIL DRAININ PIPE WITH CAP: \u2022 Oil draining facilities<\/p>\n<p>CANOPY : \u2022 Single piece hinged soundproof canopy equipped with pneumatic arms and handles to lift up the canopy allowing easy access to the genset for maintenance purposes. \u2022 Simple handling operations with central lifting eye<\/p>\n<ul>\n<li>Baseframe: PLASTIC FUEL TANK, COMPLETE WITH: \u2022 Filler neck \u2022 Air breather (ventilation pipe) \u2022 External fuel refilling<\/li>\n<li>Text noise: SOUNDPROOF : \u2022 Noise attenuation thanks to soundproofing material (polyurethane foam) and efficient residential silencer placed inside the canopy.<\/li>\n<\/ul>\n<h3>Dimensional data<\/h3>\n<ul>\n<li>Length: 1645 (L) mm<\/li>\n<li>Width: 870 (W) mm<\/li>\n<li>Height: 1072 (H) mm<\/li>\n<li>Dry weight: 472 kg<\/li>\n<li>Fuel tank capacity: 51 l<\/li>\n<li>Fuel tank material: Plastic<\/li>\n<\/ul>\n<h3>Autonomy<\/h3>\n<ul>\n<li>Fuel consumption @ 75% prp: 2.75 l\/h<\/li>\n<li>Fuel consumption @ 100% prp: 3.60 l\/h<\/li>\n<li>Running time 75% prp: 18.55 h<\/li>\n<li>Running time 100% prp: 14.17 h<\/li>\n<\/ul>\n<h3>Noise level<\/h3>\n<ul>\n<li>Guaranteed noise level (lwa): 95 dB(A)<\/li>\n<li>Noise pressure level @ 7 m: 66 dB(A)<\/li>\n<\/ul>\n<h3>Installation data<\/h3>\n<ul>\n<li>Total air flow: 42.38 m\u00b3\/min<\/li>\n<li>Exhaust gas flow: 2.7 m\u00b3\/min<\/li>\n<li>Exhaust gas temperature: 445 \u00b0C<\/li>\n<\/ul>\n<h3>Electrical data<\/h3>\n<ul>\n<li>Max current: 49.00 A<\/li>\n<li>Circuit breaker: 50 A<\/li>\n<\/ul>\n<h3>Control panel availability<\/h3>\n<ul>\n<li>Manual control panel: MCP<\/li>\n<li>Automatic control panel: ACP<\/li>\n<\/ul>\n<h3>Mcp &#8211; manual control panel<\/h3>\n<p>Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets<\/p>\n<p><strong>INSTRUMENTATION (ANALOGUE<\/strong>)<br \/>\u2022 Voltmeter (1 phase)<br \/>\u2022 Ammeter (1 phase)<br \/>\u2022 Hours-counter<\/p>\n<ul>\n<li>Second part of the text: COMMANDS AND OTHERS \u2022 Start\/stop selector switch with key (Glow plugs preheating function also included). \u2022 Emergency stop button installed on canopy side.<\/li>\n<li>Third part of the text: PROTECTION WITH ALARM \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature \u2022 Earth Fault. PROTECTIONS WITH SHUTDOWN \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature. \u2022 Circuit breaker protection<\/li>\n<li>Part4: OTHERS \u2022 Emergency stop button<\/li>\n<\/ul>\n<h3>Out put panel mcp<\/h3>\n<ul>\n<li>Power cables connection to circuit breaker.: \u221a<\/li>\n<\/ul>\n<h3>Acp &#8211; automatic control panel<\/h3>\n<p>Automatic control panel mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set. <\/p>\n<p><strong>INSTRUMENTATION DIGITAL<\/p>\n<p><\/strong>\u2022 Mains voltage.<br \/>\u2022 Generating set voltage (3 phases).<br \/>\u2022 Generating set frequency.<br \/>\u2022 Generator set current.<br \/>\u2022 Battery voltage<br \/>\u2022 Hours-counter.<\/p>\n<p><\/p>\n<ul>\n<li>Second part of the text: COMMANDS AND OTHERS \u2022 Operation modes: OFF &#8211; Manual Starting &#8211; Automatic Starting. \u2022 Push-buttons: start\/stop, fault reset, up\/down\/page\/enter selection. \u2022 Emergency stop button. \u2022 Remote starting availability. \u2022 Automatic battery charger. \u2022 USB port.<\/li>\n<li>Third part of the text: PROTECTIONS WITH ALARM \u2022 Engine protections: low oil pressure, high engine temperature \u2022 Genset protections: under\/over voltage, overload, under\/over frequency, starting failure, under\/over battery voltage, battery charger failure PROTECTIONS WITH SHUTDOWN \u2022 Engine protections: low oil pressure, high engine temperature \u2022 Genset protection: under\/over voltage, overload, under\/over battery voltage \u2022 Circuit breaker protection<\/li>\n<li>Part4: OTHERS \u2022 Cover protection Power switch<\/li>\n<\/ul>\n<h3>Out put panel acp<\/h3>\n<ul>\n<li>Plinth row for connection from acp to lts panel.: \u221a<\/li>\n<li>Power cables connection to circuit breaker.: \u221a<\/li>\n<\/ul>\n<h3>Optional features:<\/h3>\n<ul>\n<li>To be ordered with equipment  (when necessary): :<\/li>\n<\/ul>\n<h3>Engine supplements<\/h3>\n<ul>\n<li>Coolant pre-heating system: PHS<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.pramac.com\/api\/v1\/get-pdf-product-card?product_code=1175&amp;url=https%3A%2F%2Fwww.pramac.com%2Fproduct-card%3FprodKrid%3D1175%26folder%3D290%26charType%3D3%26brandKrid%3D1%26kLang%3Den_GB%26marketKid%3D252\">Datasheet (PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model: Pramac GBW15P. Frequency: 50 Hz.<\/p>\n","protected":false},"featured_media":54237,"template":"","meta":{"_acf_changed":false},"product_brand":[8760],"product_cat":[1033],"product_tag":[],"class_list":["post-54649","product","type-product","status-publish","has-post-thumbnail","product_brand-pramac","product_cat-industrial-generators","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/54649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/54237"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=54649"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=54649"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=54649"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=54649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}