{"id":54613,"date":"2026-11-24T09:31:38","date_gmt":"2026-11-24T09:31:38","guid":{"rendered":"https:\/\/proair.ee\/toode\/pramac-gsw220v-alt-ls-murasummutusega-diiselgeneraator\/"},"modified":"2026-11-24T10:59:19","modified_gmt":"2026-11-24T10:59:19","slug":"pramac-gsw220v-alt-ls-murasummutusega-diiselgeneraator","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pramac-gsw220v-alt-ls-murasummutusega-diiselgeneraator\/","title":{"rendered":"Pramac GSW220V (Alt. LS) soundproof diesel generator"},"content":{"rendered":"<p>Model: Pramac GSW220V (Alt. LS)<\/p>\n<h3>Main features<\/h3>\n<ul>\n<li>Frequency: 50 Hz<\/li>\n<li>Voltage: 400 V<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Phase: 3<\/li>\n<\/ul>\n<h3>Power rating<\/h3>\n<ul>\n<li>Emergency standby power esp: 220.00 kVA<\/li>\n<li>Emergency standby power esp: 176.00 kW<\/li>\n<li>Prime power prp: 202.23 kVA<\/li>\n<li>Prime power prp: 161.78 kW<\/li>\n<\/ul>\n<h3>Rating definitions<\/h3>\n<p><b>Ratings definition (ISO-8528-1)<\/b><\/p>\n<p>ESP<\/p>\n<ul>\n<li>Emergency Standby Power:<\/li>\n<\/ul>\n<p>It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.<\/p>\n<p>PRP<\/p>\n<ul>\n<li>Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power.<\/li>\n<\/ul>\n<h3>Engine specifications<\/h3>\n<ul>\n<li>Engine brand: Volvo<\/li>\n<li>Model: TAD733GE<\/li>\n<li>[50hz] exhaust emission level: Stage II<\/li>\n<li>Engine cooling system: Water<\/li>\n<li>Nr. of cylinder and disposition: 6 in line<\/li>\n<li>Displacement: 7150 cm\u00b3<\/li>\n<li>Aspiration: Turbocharged intercooled<\/li>\n<li>Speed governor: Electronic<\/li>\n<li>Prime gross power prp: 181 kW<\/li>\n<li>Maximum gross power ltp esp: 201 kW<\/li>\n<li>Oil capacity: 34 l<\/li>\n<li>Lube oil consumption prp (max): 0.10 %<\/li>\n<li>Coolant capacity: 38.4 l<\/li>\n<li>Fuel: Diesel<\/li>\n<li>Specific fuel consumption 75% prp: 214 g\/kWh<\/li>\n<li>Specific fuel consumption prp: 216 g\/kWh<\/li>\n<li>Starting system: Electric<\/li>\n<li>Starting engine capability: 5 kW<\/li>\n<li>Electric circuit: 12 V<\/li>\n<\/ul>\n<h3>Engine equipment<\/h3>\n<ul>\n<li>Starting system: ENGINE EQUIPMENT Standards The engine performance corresponds to ISO 3046, BS 5514 and DIN 6271. Power output guaranteed within 0 to +2% att rated ambient conditions at delivery. Ratings are based on ISO 8528. Engine speed governing in accordance with ISO 3046\/IV, class A1 and ISO 8528-5 class G3 Engine and block \u2022 Optimized cast iron cylinder block with optimum distribution of forces \u2022 Drop forged steel connecting rods \u2022 Keystone top compression rings for long service life \u2022 Replaceable valve guides and valve seats Fuel system \u2022 Washable fuel prefilter with water separator \u2022 Fine fuel filter of disposable type \u2022 Rotary low-pressure fuel pump Lubrication system \u2022 Rotary displacement oil pump driven by the crankshaft \u2022 Deep centre oil sump \u2013 Oil filler on top \u2013 Oil dipstick, short in front \u2022 Integrated full flow oil cooler, side-mounted\u2013 Integrated full flow oil cooler, side-mounted Cooling system \u2022 Belt driven, maintenance-free coolant pump with high degree of efficiency \u2022 Efficient cooling with accurate coolant control through a water distribution duct in the cylinder block \u2022 Reliable thermostat with minimum pressure drop<\/li>\n<\/ul>\n<h3>Alternator specifications<\/h3>\n<ul>\n<li>Alternator: Leroy Somer<\/li>\n<li>Model: LSA46.3 S3<\/li>\n<li>Voltage: 400 V<\/li>\n<li>Frequency: 50 Hz<\/li>\n<li>Power factor: 0.8 cos \u03d5<\/li>\n<li>Poles: 4<\/li>\n<li>Type: Brushless<\/li>\n<li>Voltage tolerance: 0.5 %<\/li>\n<li>Efficiency @ 75% load: 93.1 %<\/li>\n<li>Class: H<\/li>\n<li>Ip protection: 23<\/li>\n<\/ul>\n<h3>Alternator equipment<\/h3>\n<ul>\n<li>Mechanical structure text: SPECIALLY ADAPTED TO APPLICATIONS The alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. TOP OF THE RANGE ELECTRICAL PERFORMANCE \u25cf Class H insulation. \u25cf Standard 12 wire re-connectable winding, 2\/3 pitch, type no. 6. \u25cf High efficiency and motor starting capacity. \u25cf R 791 interference suppression conforming to standard EN 55011 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM \u25cf Excitation system: AREP<\/li>\n<li>Voltage regulator text: REINFORCED MECHANICAL STRUCTURE \u25cf Compact rigid assembly to better withstand generator vibrations. \u25cf Steel frame \u25cf Cast iron flanges and shields. \u25cf Single-bearing designed to be suitable for heat engines. \u25cf Half-key balancing bearing. \u25cf Sealed for life ball bearing. PROTECTION SYSTEM SUITED TO THE ENVIRONMENT \u25cf The LSA is IP 23. \u25cf Winding Protection for clean environments with relative humidity \u2264 95%, including indoor marine environments. COMPLIANT WITH INTERNATIONAL STANDARDS The LSA alternator conforms to the main international standards and regulations: &#8211; IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA \/ UL 1146 (UL 1004 on request), marine regulations, etc. The LSA \u00a0is designed, manufactured and marketed in an ISO 9001 environment and ISO 14001.<\/li>\n<\/ul>\n<h3>Genset equipment<\/h3>\n<p><strong>BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH:<\/strong><\/p>\n<p>\u2022 Anti-vibration mountings properly sized<\/p>\n<p>\u2022 Welded or Screwed support legs. (according to canopy size)<sub><\/p>\n<p><\/sub><\/p>\n<p>OIL DRAININ PIPE WITH CAP : \u2022 Oil draining facilities ENGINE COMPLETE WITH: \u2022 Battery \u2022 Liquids (no fuel)<\/p>\n<p>CANOPY : \u2022 Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. \u2022 Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles; Detachable panels, with screws holes protected by rubber tap. \u2022 Control panel protection door provided with suitable window and lockable handle. \u2022 Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. \u2022 Single detachable lifting eye placed on the roof.<\/p>\n<ul>\n<li>Baseframe: PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: \u2022 Filler neck \u2022 Air breather (ventilation pipe) \u2022 Minimum fuel level sensor<\/li>\n<li>Text noise: SOUNDPROOF : \u2022 Noise attenuation thanks to soundproofing material \u2022 Efficient residential silencer placed inside the canopy<\/li>\n<\/ul>\n<h3>Dimensional data<\/h3>\n<ul>\n<li>Length: 3400 (L) mm<\/li>\n<li>Width: 1250 (W) mm<\/li>\n<li>Height: 1980 (H) mm<\/li>\n<li>Dry weight: 2535 kg<\/li>\n<li>Fuel tank capacity: 350 l<\/li>\n<li>Fuel tank material: Plastic<\/li>\n<\/ul>\n<h3>Autonomy<\/h3>\n<ul>\n<li>Fuel consumption @ 75% prp: 34.76 l\/h<\/li>\n<li>Fuel consumption @ 100% prp: 46.54 l\/h<\/li>\n<li>Running time 75% prp: 10.07 h<\/li>\n<li>Running time 100% prp: 7.52 h<\/li>\n<\/ul>\n<h3>Noise level<\/h3>\n<ul>\n<li>Guaranteed noise level (lwa): 94 dB(A)<\/li>\n<li>Noise pressure level @ 7 m: 65 dB(A)<\/li>\n<\/ul>\n<h3>Installation data<\/h3>\n<ul>\n<li>Total air flow: 238.30 m\u00b3\/min<\/li>\n<li>Exhaust gas flow: 31.8 m\u00b3\/min<\/li>\n<li>Exhaust gas temperature: 530 \u00b0C<\/li>\n<\/ul>\n<h3>Electrical data<\/h3>\n<ul>\n<li>Battery capacity: 140 Ah<\/li>\n<li>Max current: 317.55 A<\/li>\n<li>Circuit breaker: 320 A<\/li>\n<\/ul>\n<h3>Control panel availability<\/h3>\n<ul>\n<li>Manual control panel: MCP<\/li>\n<li>Manual control panel full option: MPF<\/li>\n<li>Automatic control panel: ACP<\/li>\n<li>Modular parallel panel: MPP<\/li>\n<\/ul>\n<h3>Mcp &#8211; manual control panel<\/h3>\n<p>Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle.<\/p>\n<p><strong>INSTRUMENTATION (ANALOGUE<\/strong>)<\/p>\n<p>\u2022 Voltmeter (1 phase)<br \/>\u2022 Ammeter (1 phase)<br \/>\u2022 Hours-counter<\/p>\n<p><strong>COMMANDS <\/strong><\/p>\n<p>\u2022 Start\/stop selector switch with key <br \/>\u2022 Emergency stop button <\/p>\n<p><\/p>\n<ul>\n<li>Second part of the text: PROTECTION WITH ALARM \u2022 Low fuel level \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature \u2022 Earth Fault.<\/li>\n<li>Third part of the text: PROTECTIONS WITH SHUTDOWN \u2022 Low fuel level \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature. \u2022 Circuit breaker protection: III poles \u2022 Emergency stop button<\/li>\n<li>Part4: OTHERS PROTECTIONS \u2022 Panel protected through door with lockable handle.<\/li>\n<\/ul>\n<h3>Out put panel mcp<\/h3>\n<ul>\n<li>External terminal board (etb): Optional<\/li>\n<li>Socket kit: Optional<\/li>\n<\/ul>\n<h3>Mpf &#8211; manual control panel full option<\/h3>\n<p>Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle<\/p>\n<p><strong>INSTRUMENTATION (ANALOGUE<\/strong>)<\/p>\n<p>\u2022 Voltmeter with selector switch (3 phases)<br \/>\u2022 Frequency meter<br \/>\u2022 Ammeter with selector switch (3 phases)<br \/>\u2022 Hours-counter<br \/>\u2022 Fuel level indicator<br \/>\u2022 Oil pressure indicator<br \/>\u2022 Engine temperature indicator<\/p>\n<p><strong>COMMANDS <\/strong><\/p>\n<p>\u2022 Start\/stop selector switch with key <br \/>\u2022 Emergency stop button <\/p>\n<ul>\n<li>Second part of the text: PROTECTION WITH ALARM \u2022 Low fuel level \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature \u2022 Earth Fault<\/li>\n<li>Third part of the text: PROTECTIONS WITH SHUTDOWN \u2022 Low fuel level \u2022 Battery charger failure \u2022 low oil pressure \u2022 high engine temperature \u2022 Circuit breaker protection: III poles \u2022 Emergency stop button<\/li>\n<li>Part4: OTHERS PROTECTIONS \u2022 Panel protected through door with lockable handle<\/li>\n<\/ul>\n<h3>Out put panel mpf<\/h3>\n<ul>\n<li>Etb- external terminal board: ETB<\/li>\n<li>Socket kit: Standard<\/li>\n<li>Individual cb and earth fault protection: \u221a<\/li>\n<li>3p+n+t 400v 63a ip67: 1 n<\/li>\n<li>3p+n+t cee 400v 16a ip67: 1 n<\/li>\n<li>230v\/16a 2p+t cee ip67: 1 n<\/li>\n<li>230v 16a schuko ip68: 1 n<\/li>\n<\/ul>\n<h3>Acp &#8211; automatic control panel<\/h3>\n<p>Mounted on the genset, complete with digital control unit for monitoring, control and protection of the generating set, protected through door with lockable handle<\/p>\n<p><strong>DIGITAL INSTRUMENTATION <\/strong><br \/>\u2022 Generating set voltage (3 phases)<br \/>\u2022 Mains voltage<br \/>\u2022 Generating set frequency <br \/>\u2022 Generating set current (3 phases) <br \/>\u2022 Battery voltage<br \/>\u2022 Power (kVA &#8211; kW &#8211; kVAr)<br \/>\u2022 Power factor Cos \u03c6<br \/>\u2022 Hours-counter<br \/>\u2022 Engine speed r.p.m.<br \/>\u2022 Fuel level (%) <br \/>\u2022 Engine temperature (depending on model)<\/p>\n<ul>\n<li>Second part of the text: COMMANDS AND OTHERS \u2022 Four operation modes: OFF &#8211; Manual starting &#8211; Automatic starting &#8211; Automatic test \u2022 Pushbutton for forcing Mains contactor or Genset contactor \u2022 Push-buttons: start\/stop, fault reset, up\/down\/page\/enter selection \u2022 Remote starting availability \u2022 DC system disconnection switch \u2022 Acoustic alarm \u2022 Automatic battery charger \u2022 RS232 Communication port \u2022 Settable PASSWORD for protection level<\/li>\n<li>Third part of the text: PROTECTIONS WITH ALARM \u2022 Engine protections: low fuel level, low oil pressure, high engine temperature \u2022 Genset protections: under\/over voltage, overload, under\/over frequency, starting failure, under\/over battery voltage PROTECTIONS WITH SHUTDOWN \u2022 Engine protections: low fuel level, low oil pressure, high engine temperature \u2022 Genset protection: under\/over voltage, overload, under\/over battery voltage, battery charger failure \u2022 Circuit breaker protection: III poles \u2022 Earth Fault included in the control unit<\/li>\n<li>Part4: OTHERS PROTECTIONS \u2022 Emergency stop button \u2022 Panel protected through door with lockable handle<\/li>\n<\/ul>\n<h3>Out put panel acp<\/h3>\n<ul>\n<li>Predisposed for remote control optional:: RCG<\/li>\n<li>External terminal board (etb): Optional<\/li>\n<li>Socket kit: Optional<\/li>\n<\/ul>\n<h3>Mpp &#8211; modular parallel panel<\/h3>\n<ul>\n<li>Part  mpp: Mounted on the genset, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple gen-sets operating in standby or parallel modes (up to 32 gen-sets in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) \u2022 Mains: voltage, Intensity, Frequency. \u2022 Mains kW &#8211; kVAr -Power factor Cos f. \u2022 Generating set voltage (3 phases). \u2022 Generating set frequency. \u2022 Generating set current (3 phases). \u2022 Generating set Power (kVA &#8211; kW &#8211; kVAr). \u2022 Generating set Power factor Cos f. \u2022 Generating set kWh and kVAh. \u2022 Battery voltage. \u2022 Hours-counter. \u2022 Engine speed r.p.m. \u2022 Fuel level (%). \u2022 Engine temperature (depending on model). \u2022 Oil pressure (depending on model).<\/li>\n<li>Second part of the text: COMMAND AND OTHERS \u2022 Graphical display 128&#215;64 pixels. \u2022 Operation modes: OFF &#8211; AMF function &#8211; Single Parallel to mains Island application &#8211; Single Parallel to Mains AMF application &#8211; Multiple parallel genset Island application. \u2022 Pushbutton for forcing Mains Breaker\/contactor or Genset Breaker\/contactor. \u2022 Push-buttons: start\/stop, fault reset, up\/down\/page\/enter selection. \u2022 Multiple parallel and Power Management operation with digital load\u00a0 AVR sharing. \u2022 Automatic synchronizing and power control (via speed goveroner or ECU) \u2022 Baseload Import\/Export and Peak shaving \u2022 Voltage and PF control (AVR). \u2022 Configurable digital I\/O (12\/12) and analogue inputs (3). \u2022 Integrate PLC programmable functions. \u2022 Event-based history (up to 500records). \u2022 Selectable measurement range 120\/277V and 0-1\/0-5A. \u2022 Remote starting and Blocking signal availability. \u2022 DC system disconnection switch. \u2022 Acoustic alarm. \u2022 Automatic battery charger. \u2022 2xRS232\/RS485\/USB Comunication ports. \u2022 Settable PASSWORD for protection level.<\/li>\n<li>Third part of the text: PROTECTION WITH ALARM AND SHUTDOWN \u2022 Engine protections: low fuel level, low oil pressure, high engine temperature. \u2022 Genset protections: under\/over voltage, overload, under\/over frequency, starting failure, under\/over battery voltage \u2022 Others: overcurrent, shortcircuit, reverse power, Earth fault<\/li>\n<li>Part4: OTHERS PROTECTION : \u2022 Circuit breaker protection: IV poles Motorized. \u2022 Emergency stop button. \u2022 Panel protected through door with lochetable handle<\/li>\n<\/ul>\n<h3>Out put panel mpp<\/h3>\n<ul>\n<li>Multi-pin  connectors (in and out ) for parallel with other generators: 2 n<\/li>\n<li>Connecting cable with 2 connectors multipin  (length 10m): 1 n<\/li>\n<li>External terminal board: ETB<\/li>\n<\/ul>\n<h3>Optional features:<\/h3>\n<ul>\n<li>To be ordered with equipment  (when necessary): :<\/li>\n<\/ul>\n<h3>Control panel supplement<\/h3>\n<ul>\n<li>Rcg &#8211; various supplements for remote controls &#8211; available for models:: ACP MPP<\/li>\n<li>Tlp &#8211; various supplements for remote signals &#8211; available for models:: ACP MPP<\/li>\n<li>Adi &#8211; adjustable differential intensity &#8211;  available only for models:: ACP<\/li>\n<li>Tif &#8211; iv poles circuit breaker instead of iii &#8211; available for models:: ACP MCP<\/li>\n<li>Etb &#8211; external terminal board &#8211; available for models:: MCP ACP<\/li>\n<\/ul>\n<h3>Socket kit<\/h3>\n<ul>\n<li>Skb socket kit b &#8211; available for models:: ACP MCP<\/li>\n<li>Component version: IP67<\/li>\n<li>Individual cb and earth fault protection: \u221a<\/li>\n<li>3p+n+t 400v 63a ip67: 1 n<\/li>\n<li>230v\/16a 2p+t cee ip67: 1 n<\/li>\n<li>230v 16a schuko ip68: 1 n<\/li>\n<li>3p+n+t cee 400v 16a ip67: 1 n<\/li>\n<li>Nb:  for assembly is necessary:: ETB<\/li>\n<\/ul>\n<h3>Genset equipment<\/h3>\n<ul>\n<li>Automatic fuel pump: ACP MPP<\/li>\n<\/ul>\n<h3>Extended fuel tank<\/h3>\n<ul>\n<li>Fuel tank capacity: 1750 l<\/li>\n<li>Length (genset): 3414 (L) mm<\/li>\n<li>Width (genset): 1398 (W) mm<\/li>\n<li>Height (genset): 2749 (H) mm<\/li>\n<\/ul>\n<h3>Engine supplements<\/h3>\n<ul>\n<li>Coolant pre-heating system: PHS<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.pramac.com\/api\/v1\/get-pdf-product-card?product_code=11641&amp;url=https%3A%2F%2Fwww.pramac.com%2Fproduct-card%3FprodKrid%3D11641%26folder%3D290%26charType%3D3%26brandKrid%3D1%26kLang%3Den_GB%26marketKid%3D252\">Datasheet (PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model: Pramac GSW220V (Alt. LS).<\/p>\n","protected":false},"featured_media":54227,"template":"","meta":{"_acf_changed":false},"product_brand":[8760],"product_cat":[1033],"product_tag":[],"class_list":["post-54613","product","type-product","status-publish","has-post-thumbnail","product_brand-pramac","product_cat-industrial-generators","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/54613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/54227"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=54613"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=54613"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=54613"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=54613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}