{"id":53067,"date":"2026-10-19T13:37:01","date_gmt":"2026-10-19T13:37:01","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-ite-50-isolatsioonitester\/"},"modified":"2026-10-19T18:09:00","modified_gmt":"2026-10-19T18:09:00","slug":"pce-instruments-pce-ite-50-isolatsioonitester","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-ite-50-isolatsioonitester\/","title":{"rendered":"PCE Instruments PCE-ITE 50 insulation tester"},"content":{"rendered":"<p>Robust Insulation Tester\/ Electrical resistance \/Earthing resistance \/<\/p>\n<p>**Loop impedance \/ Voltage measurement \/Low resistance measurement \/RCD test**<\/p>\n<p>The PCE-ITE 50 is a robust installation tester with a large 3.5&quot; TFT color LCD display. The installation tester PCE-ITE 50 also offers, in addition to the various measuring modes such as insulation resistance, grounding resistance, loop impedance, voltage, low-impedance measurement and RCD test with the camera function, the possibility of documenting suitable photos with the measurements. With the installation tester PCE-ITE 50, you can ensure that fixed installations are safely and correctly installed. Thanks to the dual display, the intuitive symbols and the high viewing angle, you can comfortably and quickly perform your measurements with the PCE-ITE 50 installation tester.With the low-resistance measurement of the PCE-ITE 50 installation tester, you can check grounding conductors, potential equalization rails and protective conductors for low impedance.<\/p>\n<p>The measuring range for low-resistance measurement with the installation teser PCE-ITE 50 is in the range of 0 &#8211; 2000 \u03a9 with a resolution of 0.001 &#8211; 1 \u03a9. Probably the most important measurement of the installation tester PCE-ITE 50 is the measurement of insulation resistance. Electrical cables are placed under voltage during the insulation measurement in order to detect fault currents, Which generate material migration or heat. In most cases, these current faults are so minimal that they are not detected by protective devices and in the worst case they can lead to a fire. The installation tester PCE-ITE 50 can carry out installation measurement with a test voltage of 125V, 250V, 500V or 1000V. The load current is in each case 1 mA. The PCE-ITE 50 installation tester is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (ground reference or potential reference) and to protect against short-circuit currents and overvoltages, the earthing resistor should be as low-impedance as possible. With a measuring range of 0 &#8230; 2000 \u03a9 with a resolution of 0.01 &#8230; 1 \u03a9, the installation tester PCE-ITE 50 offers all the prerequisites for a meaningful measurement of the grounding resistance.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>3.5&quot; color TFT LCD display<\/li>\n<li>Loop resistance L-N, L-PE and N-PE<\/li>\n<li>Adjustable FI test current<\/li>\n<li>SD card and Bluetooth<\/li>\n<li>Dual display<\/li>\n<li>Good \/ bad FI test<\/li>\n<li>Low Ohm measurement<\/li>\n<li>Up to 1000V terminal voltage<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<p>Isolation test Terminal voltage Measuring range Resolution Accuracy Load current Short circuit current 125V (0 &#8230; 10 %)0,125 &#8230; 4 M\u03a9 0.001 M\u03a9\u00b1 (2% + 10 digits)1-mA @ Last 125 k\u03a9&lt;= 1-mA 4,001 &#8230; 40 M\u03a9 0.01 M\u03a9\u00b1 (2% + 10 digits) 40,01 &#8230; 400 M\u03a9 0.1 M\u03a9\u00b1 (4% + 5 digits) 400,1 &#8230; 1000 M\u03a9 1 M\u03a9\u00b1 (5% + 5 digits) 250V (0 &#8230; 10 %)0,125 &#8230; 4 M\u03a9 0.001 M\u03a9\u00b1 (2% + 10 digits)1-mA @ Last 250 k\u03a9&lt;= 1-mA 4,001 &#8230; 40 M\u03a9 0.01 M\u03a9\u00b1 (2% + 10 digits) 40,01 &#8230; 400 M\u03a9 0.1 M\u03a9\u00b1 (3% + 2 digits) 400,1 &#8230; 1000 M\u03a9 1 M\u03a9\u00b1 (3% + 2 digits) 500V (0 &#8230; 10 %)0,125 &#8230; 4 M\u03a9 0.001 M\u03a9\u00b1 (2% + 10 digits)1-mA @ Last 500 k\u03a9&lt;= 1-mA 4,001 &#8230; 40 M\u03a9 0.01 M\u03a9\u00b1 (2% + 10 digits) 40,01 &#8230; 400 M\u03a9 0.1 M\u03a9\u00b1 (3% + 2 digits) 400,1 &#8230; 1000 M\u03a9 1 M\u03a9\u00b1 (4% + 5 digits) 1000 V (0 &#8230; 10 %)0,125 &#8230; 4 M\u03a9 0.001 M\u03a9\u00b1 (3% + 10 digits)1-mA @ Last 1 M\u03a9&lt;= 1-mA 4,001 &#8230; 40 M\u03a9 0.01 M\u03a9\u00b1 (2% + 10 digits) 40,01 &#8230; 400 M\u03a9 0.1 M\u03a9\u00b1 (3% + 2 digits) 400,1 &#8230; 1000 M\u03a9 1 M\u03a9\u00b1 (4% + 5 digits) Low Ohm Measuring range Resolution Accuracy Max. open circuit voltage Overload protection 2,000 \u03a9 0.001 \u03a9\u00b1 (1.5% + 30 digits)5.8V 250 Vrms 20,00 \u03a9 0.01 \u03a9\u00b1 (1.5% + 3 digits)5.8V 250 Vrms 200,0 \u03a9 0.1 \u03a9\u00b1 (1.5% + 3 digits)5.8V 250 Vrms 2000 \u03a9 1 \u03a9\u00b1 (1.5% + 5 digits)5.8V 250 Vrms Continuity tester Measuring range Resolution Max. open circuit voltage Overload protection Short circuit current 2000 \u03a9 0.01 \u03a9 5.8V 250 Vrms&gt;= 200-mA Grinding resistance L-PE (Hi-Amp): Load current 4.0 A Measuring range Resolution Accuracy 0.23 &#8230; 9.99 \u03a9 0.01 \u03a9\u00b1 (4% + 4 digits) 10.0 &#8230; 99.9 \u03a9 0.1 \u03a9\u00b1 (4% + 4 digits) 100 &#8230; 999 \u03a9 1 \u03a9\u00b1 (4% + 4 digits) L-PE (without tripping): Load current 15-mA Measuring range Resolution Accuracy 0.23 &#8230; 9.99 \u03a9 0.01 \u03a9\u00b1 (5% + 6 digits) 10.0 &#8230; 99.9 \u03a9 0.1 \u03a9\u00b1 (5% + 6 digits) 100 &#8230; 999 \u03a9 1 \u03a9\u00b1 (5% + 6 digits) L-N: Load current 4.0 A Measuring range Resolution Accuracy 0.23 &#8230; 9.99 \u03a9 0.01 \u03a9\u00b1 (4% + 4 digits) 10.0 &#8230; 99.9 \u03a9 0.1 \u03a9\u00b1 (4% + 4 digits) 100 &#8230; 999 \u03a9 1 \u03a9\u00b1 (4% + 4 digits) RCD Test RCD (In)10-mA, 30-mA, 100-mA, 300-mA, 650-mA, 1 A Factors x 1\/2, x1, x2, x5 Accuracy of the tripping time\u00b1 (1% + 1 ms) Signal form of the test current Sine (AC) Tripping characteristics G and S Release time 0\u00b0 or 180\u00b0 Voltage range 194 &#8230; 260V AC (50\/60 Hz) Accuracy of current measurement\u00b1 (5% + 2 digits) RCD Types Type A, Type B Voltage measurement Measuring range Resolution Accuracy 80&#8230;500 V AC\/DC 1 V\u00b1 (2 % + 2 digits) Frequency measurement Measuring range Resolution Accuracy 45&#8230;65 Hz 1 Hz\u00b12 Hz Grounding measurement Measuring range Resolution Accuracy 0.00&#8230;99.99 \u03a9 0.01 \u03a9\u00b1 (2% + 30 digits) 100.0&#8230;999.9 \u03a9 0.1 \u03a9\u00b1 (2% + 6 digits) 1000&#8230;2000 \u03a9 1 \u03a9\u00b1 (2% + 6 digits) General specifications Power supply 8 x 1.2 &#8230; 1.5V AA batteries Operating time ca. 15 h Measurement category CAT III 600V Protection class IP 65 Display 3.5&quot; TFT (320 x 240 Pixel) Operating environment 0 &#8230; 45\u00b0C 0 &#8230; 95% rH, non condensing Measurements 24.2 x 10.5 x 14.5 cm Weight 1.56 kg \/ 3.4 lbs<\/p>\n<h3>Delivery scope<\/h3>\n<p>1 x Insulation Tester PCE-ITE 50 1 x User manual<\/p>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=2871765&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=1715842&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Robust Insulation Tester\/ Electrical resistance \/Earthing resistance \/. **Loop impedance \/ Voltage measurement \/Low resistance measurement \/RCD test**.<\/p>\n","protected":false},"featured_media":51766,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[975],"product_tag":[],"class_list":["post-53067","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-measuring-instruments","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/53067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/51766"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=53067"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=53067"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=53067"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=53067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}