{"id":49745,"date":"2026-10-16T16:29:55","date_gmt":"2026-10-16T16:29:55","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-pdfl-10-temperatuuri-ja-niiskusandmeloger\/"},"modified":"2026-10-16T20:51:21","modified_gmt":"2026-10-16T20:51:21","slug":"pce-instruments-pce-pdfl-10-temperatuuri-ja-niiskusandmeloger","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-pdfl-10-temperatuuri-ja-niiskusandmeloger\/","title":{"rendered":"PCE Instruments PCE-PDFL 10 temperature data logger"},"content":{"rendered":"<p>Temperature Data Logger with abs. air pressure sensor \/ measuring range -30 &#8230; 60\u00b0C (-22 &#8230; 140\u00b0F)\/<\/p>\n<p>instant data export via PDF and CSV \/ software \/ LC display \/ USB-A \/<\/p>\n<p>data memory for 13340 measuring points \/ optional with ISO calibration certificate<\/p>\n<p>The Temperature Data Logger has a measuring range of -30 &#8230; 60\u00b0C\/ -22 &#8230; 140\u00b0F and can be used in cold environments. In addition to temperature and humidity measurement, the Temperature Data Logger can also measure the absolute air pressure in the ambient atmosphere in a measuring range between 700 &#8230; 1100 hpa. Due to the different sensors, the Temperature Data Logger already covers a wide range of measuring tasks. Typical applications of the Temperature Data Logger are, for example, the monitoring of refrigeration facilities, greenhouses or also in the monitoring of an office workplace.<\/p>\n<p>The measured values are stored on the internal memory of the Temperature Data Logger. The Temperature Data Logger has a memory capacity of 13340 measuring points. Once a measurement run has been completed, the stored measurement data can be read out from the Temperature Data Logger independently of the operating system. This is possible because the Temperature Data Logger is recognised as a mass data memory. When storing the measurement data, the measurement points are saved in a .pdf and in a .csv file.<\/p>\n<p>With the corresponding software for the Temperature Data Logger, the measured values can be displayed graphically. In addition, settings for the Temperature Data Logger can be made via the software. For example, the storage interval can be set between 1 minute and 24 hours, visual alarm limits and start\/stop pulses can be set for the Temperature Data Logger. Optionally, the Temperature Data Logger can be equipped with an ISO calibration certificate.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>Temperature, relative humidity, air pressure<\/li>\n<li>Software for evaluating the measured data<\/li>\n<li>Measuring range: -30 &#8230; 60\u00b0C \/ -22 &#8230; 140\u00b0F<\/li>\n<li>Data memory with 13340 measuring points<\/li>\n<li>Data export immediately in PDF and CSV<\/li>\n<li>Optionally with ISO calibration certificate<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<ul>\n<li>Absolute pressure \u2014 Measuring range: 700 &#8230; 1100 hPa<\/li>\n<li>Absolute pressure \u2014 Resolution: 1 hPa<\/li>\n<li>Absolute pressure \u2014 Accuracy: \u00b13 hPa<\/li>\n<li>Absolute pressure \u2014 Measurement range: min.525 mmHg<\/li>\n<li>Absolute pressure \u2014 Measurement range: 825 mmHg<\/li>\n<li>Absolute pressure \u2014 Resolution: 0,1 mmHg<\/li>\n<li>Absolute pressure \u2014 Accuracy: \u00b12.5 mmHg<\/li>\n<li>Absolute pressure \u2014 Measurement range: min.20,67 inHg<\/li>\n<li>Absolute pressure \u2014 Measurement range: 32,48 inHg<\/li>\n<li>Absolute pressure \u2014 Resolution: 0,01 inHg<\/li>\n<li>Absolute pressure \u2014 Accuracy: \u00b10.1 inHg<\/li>\n<li>Relative humidity \u2014 Measuring range: 0 &#8230; 20 % RH<\/li>\n<li>Relative humidity \u2014 Resolution: 0,1 % RH<\/li>\n<li>Relative humidity \u2014 Accuracy: \u00b15 % RH<\/li>\n<li>Relative humidity \u2014 Measuring range: 20 &#8230; 40 % RH<\/li>\n<li>Relative humidity \u2014 Resolution: 0,1 % RH<\/li>\n<li>Relative humidity \u2014 Accuracy: \u00b13.5 % RH<\/li>\n<li>Relative humidity \u2014 Measuring range: 40 &#8230; 60 % RH<\/li>\n<li>Relative humidity \u2014 Resolution: 0,1 % RH<\/li>\n<li>Relative humidity \u2014 Accuracy: \u00b13 % RH<\/li>\n<li>Relative humidity \u2014 Measuring range: 60 &#8230; 80 % RH<\/li>\n<li>Relative humidity \u2014 Resolution: 0,1 % RH<\/li>\n<li>Relative humidity \u2014 Accuracy: \u00b13.5 % RH<\/li>\n<li>Relative humidity \u2014 Measuring range: 80 &#8230; 100 % RH<\/li>\n<li>Relative humidity \u2014 Resolution: 0,1 % RH<\/li>\n<li>Relative humidity \u2014 Accuracy: \u00b15 % RH<\/li>\n<li>Temperature \u2014 Measuring range: -30 &#8230; 0 \u00b0C<\/li>\n<li>Temperature \u2014 Resolution: 0,1 \u00b0C<\/li>\n<li>Temperature \u2014 Accuracy: \u00b11.0 \u00b0C<\/li>\n<li>Temperature \u2014 Measuring range: 0 &#8230; 60 \u00b0C<\/li>\n<li>Temperature \u2014 Resolution: 0,1 \u00b0C<\/li>\n<li>Temperature \u2014 Accuracy: \u00b10.5 \u00b0C<\/li>\n<li>Temperature \u2014 Measuring range: -22 &#8230; +32 \u00b0F<\/li>\n<li>Temperature \u2014 Resolution: 0,1 \u00b0F<\/li>\n<li>Temperature \u2014 Accuracy: 1.8 \u00b0F<\/li>\n<li>Temperature \u2014 Measuring range: 32 &#8230; 140 \u00b0F<\/li>\n<li>Temperature \u2014 Resolution: 0,1 \u00b0F<\/li>\n<li>Temperature \u2014 Accuracy: 0.9 \u00b0F<\/li>\n<li>General technical data \u2014 Display type: LCD<\/li>\n<li>General technical data \u2014 Display size: 0,25 Inch<\/li>\n<li>Storage medium Internal memory \u2014 Storage capacity: 13340 Measurements<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval from: 1 min.<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval to: 24 h<\/li>\n<li>Storage medium Internal memory \u2014 Interface: USB-A<\/li>\n<li>Storage medium Internal memory: Operating time 3 Year(s)<\/li>\n<li>file format CSV, PDF \u2014 Menu language: English, English (GB)<\/li>\n<li>file format CSV, PDF \u2014 Protection class (device): IP20<\/li>\n<li>file format CSV, PDF \u2014 Power supply: 5 V DC, 0.1 A<\/li>\n<li>Connector type USB-A \u2014 (Rechargeable) battery: 1 x 3 V CR2450 , lithium<\/li>\n<li>Connector type USB-A \u2014 Capacity: 600 mAh<\/li>\n<li>Connector type USB-A \u2014 Operating conditions: -30 &#8230; 60 \u00b0C , 0 &#8230; 95 % RH<\/li>\n<li>Connector type USB-A \u2014 Storage conditions: -30 &#8230; 60 \u00b0C , 0 &#8230; 95 % RH<\/li>\n<li>Connector type USB-A \u2014 Dimensions: ( L x W x H )75 x 35 x 15 mm<\/li>\n<li>Connector type USB-A \u2014 Weight: 33 g<\/li>\n<\/ul>\n<h3>Delivery scope<\/h3>\n<ul>\n<li>1 x PCE-PDFL 10 Temperature Data Logger \/ Temperature Logger<\/li>\n<li>1 x 3V button battery (CR2450)<\/li>\n<li>1 x Software CD<\/li>\n<li>1 x Instruction manual<\/li>\n<\/ul>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-u6639f5d3a1da622b.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-t6629e4eb41e284df.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=6489701&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-o67d810c8366dbdba.zip\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Temperature Data Logger with abs. air pressure sensor \/ measuring range -30 &#8230; 60\u00b0C (-22 &#8230; 140\u00b0F)\/. instant data export via PDF and CSV \/ software \/ LC display \/ USB-A \/.<\/p>\n","protected":false},"featured_media":49291,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[976],"product_tag":[],"class_list":["post-49745","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-temperature-and-humidity","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/49745","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/49291"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=49745"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=49745"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=49745"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=49745"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}