{"id":49723,"date":"2026-10-16T16:25:43","date_gmt":"2026-10-16T16:25:43","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-pa-6500-r11-energiakulu-mootja\/"},"modified":"2026-10-16T20:50:56","modified_gmt":"2026-10-16T20:50:56","slug":"pce-instruments-pce-pa-6500-r11-energiakulu-mootja","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-pa-6500-r11-energiakulu-mootja\/","title":{"rendered":"PCE Instruments PCE-PA 6500 R11 power quality analyser \/ power analyzer"},"content":{"rendered":"<p>Power Quality Analyser \/ Power Analyzer for energy monitoring \/ configuration and data transfer via app \/ measurement without interrupting the power supply \/ incl. test leads \/ compact design<\/p>\n<p>The Power Quality Analyser \/ Power Analyzer measures current and voltage values using the connected current transformers and test leads. From this, the active, apparent and reactive power are determined and transmitted to the measuring platform every second via Wi-Fi. The data is then filed historically on the Power Quality Analyser \/ Power Analyzer, processed graphically and can be analysed or exported. The measurement with the Power Quality Analyser \/ Power Analyzer is carried out using Rogowski coils or folding current transformers.<\/p>\n<p>Alternatively (if no internet connection is available), the data can be recorded in the built-in 32 GB flash memory in the form of a CSV file for further processing at a later date. An SD card adaptor is also available as an accessory, which means that the recording duration is more than one year, even when recording to the second. It is also possible to send the CSV files periodically by e-mail, upload them to a server via FTP or transfer them to the measurement platform once the measurement has been completed. Interaction with the Power Quality Analyser \/ Power Analyzer is mainly via Wi-Fi and web browser or via app (BLE).<\/p>\n<p>Power is supplied and measured via magnetic measuring tips and connection terminals or probes. The Power Quality Analyser \/ Power Analyzer can be connected into any main and sub-distribution board as well as into devices and systems &#8211; the power supply does not have to be interrupted. Managing the power supply is the top priority. Without measuring consumption and recording instrumental values such as current, voltage, frequency and power, it is virtually impossible to improve efficiency. The Power Quality Analyser \/ Power Analyzer makes it possible to monitor the entire energy consumption and helps to reduce energy costs.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>active, apparent and reactive power<\/li>\n<li>power factor and electrical energy<\/li>\n<li>8 MB internal memory<\/li>\n<li>app for Android<\/li>\n<li>data as CSV file<\/li>\n<li>measurement via Rogowski coils<\/li>\n<li>no additional mains connection necessary<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<ul>\n<li>AC voltage \u2014 Measuring range: 40 &#8230; 400 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,01 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b11 % of Rd<\/li>\n<li>Alternating current AC \u2014 Measuring range: 0 &#8230; 80 A<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,01 A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b11 % of Rd<\/li>\n<li>Active power \u2014 Measuring range: 0 W &#8230; 32 kW<\/li>\n<li>Active power \u2014 Resolution: 0,01 W<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% of Rd W<\/li>\n<li>Reactive power \u2014 Measuring range: 0 VAR &#8230; 32 kVAR<\/li>\n<li>Reactive power \u2014 Resolution: 0,01 VAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b11% of Rd<\/li>\n<li>Apparent power \u2014 Measuring range: 0 VA &#8230; 32 kVA<\/li>\n<li>Apparent power \u2014 Resolution: 0,01 VA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% of Rd<\/li>\n<li>Power factor \u2014 Measuring range: 0 &#8230; 1<\/li>\n<li>Power factor \u2014 Resolution: 0.01<\/li>\n<li>Power factor \u2014 Accuracy: \u00b11 % of Rd<\/li>\n<li>General technical data: Measuring rate 26000 Hz<\/li>\n<li>Storage medium Internal memory \u2014 Storage capacity: 32 GB<\/li>\n<li>Storage medium Internal memory: Memory capacity (additional information)separate phases: 22000 data records, summarised phases: 38000 data records<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval from: 1 s<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval to: 60 min.<\/li>\n<li>Storage medium Internal memory: Current consumption current clamp 100 mA DC<\/li>\n<li>Storage medium Internal memory: Maximum cable diameter 10 mm<\/li>\n<li>Storage medium Internal memory: Safety standard CAT III 300V<\/li>\n<li>Storage medium Internal memory: Fuse(s)1000 V, 250 mA, FF<\/li>\n<li>Storage medium Internal memory: Max. power-off capacity 100 kA<\/li>\n<li>Storage medium Internal memory \u2014 Menu language: German, English (GB), English, Spanish, French<\/li>\n<li>Storage medium Internal memory \u2014 Protection class (device): IP40<\/li>\n<li>Storage medium Internal memory \u2014 Power supply: 100 &#8230; 240 V 50\/60 Hz (+\/- 10%)<\/li>\n<li>(between neutral conductor and phase A) \u2014 (Rechargeable) battery: 1 x 3 V CR 2032 (button cell 3V) , Lithium-ion manganese oxide<\/li>\n<li>(between neutral conductor and phase A) \u2014 Capacity: 245 mAh<\/li>\n<li>(between neutral conductor and phase A): Performance 0,735 Wh<\/li>\n<li>(between neutral conductor and phase A) \u2014 Operating conditions: -5 &#8230; 40 \u00b0C , 0 &#8230; 80 % RH<\/li>\n<li>(between neutral conductor and phase A) \u2014 Storage conditions: -5 &#8230; 40 \u00b0C , 0 &#8230; 80 % RH<\/li>\n<li>(between neutral conductor and phase A) \u2014 Dimensions: ( L x W x H )123 x 96 x 36 mm<\/li>\n<li>(between neutral conductor and phase A) \u2014 Weight: 202 g<\/li>\n<\/ul>\n<h3>Delivery scope<\/h3>\n<ul>\n<li>1 x PCE-PA 6500 R11 Power Quality Analyser \/ Power Analyzer<\/li>\n<li>4 x test leads (blue, brown, black, grey) 2 m<\/li>\n<li>3 x Rogowski coils<\/li>\n<li>3 x magnetic measuring adaptors 6.6 mm<\/li>\n<li>1 x blue crocodile clip<\/li>\n<li>1 x user manual<\/li>\n<li>1 x service bag You can find the &#8220;PCE-PA 6500&#8221; app in the Play Store or in the download area.<\/li>\n<\/ul>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-k66f27ea4b3c02484.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-s66bdff5c7f8d04d4.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=5386681&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-u66b31a93e9bc4d6e.zip\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Power Quality Analyser \/ Power Analyzer for energy monitoring \/ configuration and data transfer via app \/ measurement without interrupting the power supply \/ incl. test leads \/ compact design. The Power Quality Analyser \/ Power Analyzer measures current and voltage values using the connected current transformers and test leads.<\/p>\n","protected":false},"featured_media":49228,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1004],"product_tag":[],"class_list":["post-49723","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-energy-consumption-meter","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/49723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/49228"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=49723"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=49723"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=49723"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=49723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}