{"id":49615,"date":"2026-10-16T16:02:33","date_gmt":"2026-10-16T16:02:33","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-it-110-isolatsioonitakistuse-mootur\/"},"modified":"2026-10-16T20:38:58","modified_gmt":"2026-10-16T20:38:58","slug":"pce-instruments-pce-it-110-isolatsioonitakistuse-mootur","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-it-110-isolatsioonitakistuse-mootur\/","title":{"rendered":"PCE Instruments PCE-IT 110 insulation tester \/ insulation meter"},"content":{"rendered":"<p>Insulation Tester \/ Insulation Meter \/ Test voltage up to 1000V \/ LCD color display \/ Time display \/ Data memory \/ Automatic switch-off<\/p>\n<p>The Insulation Tester \/ Insulation Meter combines the functions of a fully-fledged digital multimeter with a powerful Insulation Tester \/ Insulation Meter and is ideal for professional applications in industry, trade and energy supply. In addition to measuring voltage, current and resistance, the device also offers frequency and capacitance measurement as well as temperature measurement via the supplied type K thermocouple. The automatic range selection and the 3.5 inch LCD color display enable simple and precise operation. The Insulation Tester \/ Insulation Meter allows insulation tests with selectable test voltages from 125 V to 1000 V and measures insulation resistances of up to 6000 M\u03a9. It also supports the measurement of the polarization index (PI) and the absorption ratio (DAR), which enables a well-founded assessment of the insulation quality of cables, motors, control cabinets and electrical systems.<\/p>\n<p>Thanks to the integrated data memory, measurement results can be called up directly on the device for later analysis. The recorded data can be transferred wirelessly to a smartphone or tablet via Bluetooth &#8211; particularly practical for documentation and test reports. Other features such as automatic discharge after the measurement, MIN\/MAX\/PEAK value recording, hold function and a lock button for hands-free operation round off the device. The Insulation Tester \/ Insulation Meter fulfils the highest safety requirements in accordance with CAT IV 600V \/ CAT III 1000V and can therefore also be used safely for work in energy distribution and on building technology.<\/p>\n<p>Typical areas of application for this Insulation Tester \/ Insulation Meter include electrical installation, switch cabinet construction, maintenance of machines and systems, photovoltaic systems, the service sector and technical training centers. With its combination of versatility, precision and modern connectivity, this Insulation Tester \/ Insulation Meter is a good tool for any professional.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>Insulation test voltages 125V, 250V, 500V, 1000V<\/li>\n<li>Measuring functions: HOLD, MIN, MAX, PEAK<\/li>\n<li>PI (polarization index), DAR (absorption ratio)<\/li>\n<li>High voltage and overload indicator<\/li>\n<li>Diode test<\/li>\n<li>Automatic discharge<\/li>\n<li>Automatic switch-off<\/li>\n<li>Locking button<\/li>\n<li>Data memory with logger<\/li>\n<li>Bluetooth for app connection<\/li>\n<li>Connections for Rogowski coil<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<ul>\n<li>Direct voltage DC \u2014 Measuring range: 0 &#8230; 600 mV<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,1 mV<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.9% +5 digits)<\/li>\n<li>Direct voltage DC: Overload 1000 V<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 600 mV &#8230; 6 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,001 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.9% +5 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 6 &#8230; 60 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,01 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.9% +5 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 60 &#8230; 600 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,1 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(1% +5 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 600 &#8230; 1000 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 1 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(1% +5 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 0 &#8230; 200 \u00b5A<\/li>\n<li>Direct current DC \u2014 Resolution: 0,1 \u00b5A<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(0.9% +8 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 200 \u00b5A &#8230; 600 mA<\/li>\n<li>Direct current DC \u2014 Resolution: 0,1 mA<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(1.2% +3 Digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 600 mA &#8230; 10 A<\/li>\n<li>Direct current DC \u2014 Resolution: 0,01 A<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 0 &#8230; 60 nF<\/li>\n<li>Capacity \u2014 Resolution: 0,01 nF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(5% +35 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 60 &#8230; 600 nF<\/li>\n<li>Capacity \u2014 Resolution: 0,1 nF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.5 % +8 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 600 nF &#8230; 6 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,001 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(3% +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 6 &#8230; 60 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,01 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(3% +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 60 &#8230; 600 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,1 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(3% +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 600 &#8230; 6000 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 1 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.5% +20 Digits)<\/li>\n<li>Type K temperature \u2014 Measuring range: -20 &#8230; +600 \u00b0C<\/li>\n<li>Type K temperature \u2014 Resolution: 0,1 \u00b0C<\/li>\n<li>Type K temperature \u2014 Accuracy: \u00b1(3 % of Rd +5 \u00b0C)<\/li>\n<li>Type K temperature \u2014 Measuring range: 600 &#8230; 1000 \u00b0C<\/li>\n<li>Type K temperature \u2014 Resolution: 1 \u00b0C<\/li>\n<li>Type K temperature \u2014 Accuracy: \u00b1(3 % of Rd +5 \u00b0C)<\/li>\n<li>Type K temperature \u2014 Measuring range: -4 &#8230; +600 \u00b0F<\/li>\n<li>Type K temperature \u2014 Resolution: 0,1 \u00b0F<\/li>\n<li>Type K temperature \u2014 Accuracy: \u00b1(3% v.Mw. +9\u00b0C)<\/li>\n<li>Type K temperature \u2014 Measuring range: 600 &#8230; 1832 \u00b0F<\/li>\n<li>Type K temperature \u2014 Resolution: 1 \u00b0F<\/li>\n<li>Type K temperature \u2014 Accuracy: \u00b1(3% v.Mw. +9\u00b0C)<\/li>\n<li>AC voltage \u2014 Measuring range: 0 &#8230; 6 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,001 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% +5 Digits) @50 &#8230; 60 Hz \/ \u00b1(3% +5 Digits) @61 &#8230; 1000 Hz<\/li>\n<li>AC voltage: Overload 1000 V<\/li>\n<li>AC voltage \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 6 &#8230; 60 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,01 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% +5 Digits) @50 &#8230; 60 Hz \/ \u00b1(3% +5 Digits) @61 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 60 &#8230; 600 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,1 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% +5 Digits) @50 &#8230; 60 Hz \/ \u00b1(3% +5 Digits) @61 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 600 &#8230; 1000 V<\/li>\n<li>AC voltage \u2014 Resolution: 1 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1.2% +5 Digits) @50 &#8230; 60 Hz \/ \u00b1(3% +5 Digits) @61 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 0 &#8230; 200 \u00b5A<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,1 \u00b5A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1.2% +8 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 200 \u00b5A &#8230; 600 mA<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,1 mA<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1.2 % +5 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 600 mA &#8230; 10 A<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,01 A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 50 &#8230; 1000 Hz<\/li>\n<li>Insulation resistance: Test voltage DC 125V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 0,125 &#8230; 6 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(2% +10 Digits)<\/li>\n<li>Insulation resistance: Test voltage DC 250V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 0,25 &#8230; 6 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(2% +15 Digits) M \u03a9<\/li>\n<li>Insulation resistance: Test voltage DC 500V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 0,5 &#8230; 6 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(2% +10 Digits)<\/li>\n<li>Insulation resistance: Test voltage DC 1000V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 1 &#8230; 6 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(3% +10 Digits)<\/li>\n<li>Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 6 &#8230; 60 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,01 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(2% +10 Digits)<\/li>\n<li>Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 60 &#8230; 600 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 0,1 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(4% +5 digits)<\/li>\n<li>Insulation resistance: Test voltage DC 125V, 250V, 500V, 1000V<\/li>\n<li>Insulation resistance \u2014 Measuring range: 600 &#8230; 6000 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Resolution: 1 M \u03a9<\/li>\n<li>Insulation resistance \u2014 Accuracy: \u00b1(5% +10 Digits)<\/li>\n<li>Resistance \u2014 Measuring range: 0 &#8230; 600 \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,1 \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.2% +10 Digits)<\/li>\n<li>Resistance \u2014 Measuring range: 600 \u03a9 &#8230; 6 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,001 k\u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 6 &#8230; 60 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,01 \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 60 &#8230; 600 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,1 k\u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 600 k\u03a9 &#8230; 6 M \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.5 % +5 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 6 &#8230; 60 M \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,01 M \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(2.5% +10 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 40 &#8230; 10000 Hz<\/li>\n<li>Frequency \u2014 Resolution: 0,01 Hz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(1% +5 digits)<\/li>\n<li>General technical data \u2014 Measuring functions: MIN, MAX, HOLD, PI, DAR<\/li>\n<li>General technical data \u2014 Display type: LC colour display<\/li>\n<li>General technical data \u2014 Display size: 3,5 Inch<\/li>\n<li>General technical data \u2014 Display refresh rate: 3 x per second<\/li>\n<li>General technical data: Measuring rate 3 Hz<\/li>\n<li>Storage medium Internal memory \u2014 Storage capacity: 1800 Values<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval from: 1 s<\/li>\n<li>Storage medium Internal memory \u2014 Storage interval to: 60 min.<\/li>\n<li>Storage medium Internal memory \u2014 Interface: Bluetooth<\/li>\n<li>Storage medium Internal memory: Automatic power-off from&#8230;to 15 &#8230; 60 min.<\/li>\n<li>Storage medium Internal memory: Safety standard CAT III 1000V, CAT IV 600V<\/li>\n<li>Storage medium Internal memory: Diode test Test current: &lt;1.5 mA<\/li>\n<li>Storage medium Internal memory: Max. Voltage in open circuit: 3.2V DC<\/li>\n<li>Storage medium Internal memory \u2014 Menu language: English, English (GB)<\/li>\n<li>Storage medium Internal memory \u2014 Protection class (device): IP65<\/li>\n<li>Storage medium Internal memory \u2014 (Rechargeable) battery: 6 x 1,5 V AA battery , Alkali-manganese<\/li>\n<li>Storage medium Internal memory \u2014 Capacity: 2500 mAh<\/li>\n<li>Storage medium Internal memory \u2014 Operating conditions: 5 &#8230; 40 \u00b0C , 0 &#8230; 80 % RH<\/li>\n<li>Storage medium Internal memory \u2014 Storage conditions: -20 &#8230; 60 \u00b0C , 0 &#8230; 80 % RH<\/li>\n<li>Storage medium Internal memory \u2014 Dimensions: ( L x W x H )215 x 100 x 65 mm<\/li>\n<li>Storage medium Internal memory \u2014 Weight: 569 g<\/li>\n<\/ul>\n<h3>Delivery scope<\/h3>\n<ul>\n<li>1 x Insulation Tester \/ Insulation Meter PCE-IT 110<\/li>\n<li>1 x Temperature probe type K<\/li>\n<li>2 x Set of test leads<\/li>\n<li>1 x Transport case<\/li>\n<li>6 x 1.5V AA batteries<\/li>\n<li>1 x Instruction manual You can find the &#8220;Meterbox Pro&#8221; app in the App Store<\/li>\n<\/ul>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-z68b19e8bdd6ab6f0.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-s686662b9af075e91.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=3794073&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Insulation Tester \/ Insulation Meter \/ Test voltage up to 1000V \/ LCD color display \/ Time display \/ Data memory \/ Automatic switch-off. The Insulation Tester \/ Insulation Meter combines the functions of a fully-fledged digital multimeter with a powerful Insulation Tester \/ Insulation Meter and is ideal for professional applications in industry, trade and energy supply.<\/p>\n","protected":false},"featured_media":49032,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1003],"product_tag":[],"class_list":["post-49615","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-digital-multimeters","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/49615","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/49032"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=49615"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=49615"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=49615"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=49615"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}