{"id":49567,"date":"2026-10-16T15:52:08","date_gmt":"2026-10-16T15:52:08","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-gpa-62-energiakulu-mootja\/"},"modified":"2026-10-16T20:38:20","modified_gmt":"2026-10-16T20:38:20","slug":"pce-instruments-pce-gpa-62-energiakulu-mootja","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-gpa-62-energiakulu-mootja\/","title":{"rendered":"PCE Instruments PCE-GPA 62 power meter"},"content":{"rendered":"<p>Power Meter PCE-GPA 62 with network analyzer \/ Power and energy meter (real time) with data logger, graphic display, interface for PC and software<\/p>\n<p>The One-Phase Digital Multimeter (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50\u00ba of the harmonic waveform. The Three-Phase Digital Multimeter PCE-GPA 62 comes with a built-in graphic display to show network analyzer values. Measured values can be both recorded and transferred to a PC for further analysis.<\/p>\n<p>The One-Phase Digital Multimeter PCE-GPA 62 is a professional handheld device to determine several parameters. Thanks to the backlight display, it is possible to get an accurate reading of measured values even with poor light conditions. Although the Three-Phase Digital Multimeter PCE-GPA 62 comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when an annual recalibration is required.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>Real-time test, register and measurement of voltage and current (real<\/li>\n<li>effective)<\/li>\n<li>Measures power factor and phase angle, frequency, energy, active, reactive<\/li>\n<li>and apparent power (single-<\/li>\n<li>phase or three-phase in symmetrical networks).<\/li>\n<li>Max. conductor diameter: 55 mm \/ 2.2 in<\/li>\n<li>Graphic display<\/li>\n<li>Auto shut-off after 15 min. (this function may be disabled)<\/li>\n<li>Optional ISO calibration<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<ul>\n<li>AC voltage \u2014 Measuring range: 4 &#8230; 600 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,1 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b10.5 % \u00b15 digits<\/li>\n<li>AC voltage: Overload 800V<\/li>\n<li>AC voltage \u2014 Frequency: range 50 &#8230; 60 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 4 &#8230; 1500 A<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,1 A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b11% \u00b15 digits<\/li>\n<li>Alternating current AC: Overload 2000 A<\/li>\n<li>Alternating current AC \u2014 Frequency: range 50 &#8230; 60 Hz<\/li>\n<li>Active power \u2014 Measuring range: 10 &#8230; 999,9 W<\/li>\n<li>Active power \u2014 Resolution: 0,1 W<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Active power \u2014 Measurement range: up to 1 kW<\/li>\n<li>Active power \u2014 Measurement range: from 9,999 kW<\/li>\n<li>Active power \u2014 Resolution: 0,001 kW<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A) W<\/li>\n<li>Active power \u2014 Measuring range: 10 &#8230; 99,99 kW<\/li>\n<li>Active power \u2014 Resolution: 0,01 kW<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Active power \u2014 Measuring range: 100 &#8230; 999,9 kW<\/li>\n<li>Active power \u2014 Resolution: 0,1 kW<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Active power \u2014 Measuring range: 1000 &#8230; 9999 kW<\/li>\n<li>Active power \u2014 Resolution: 1 kW<\/li>\n<li>Active power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Reactive power \u2014 Measuring range: 10 &#8230; 999,9 VAR<\/li>\n<li>Reactive power \u2014 Resolution: 0,1 VAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b12% \u00b130 digits (&gt;20V and &gt;20 A) \/ \u00b13% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Reactive power \u2014 Measuring range: 1 &#8230; 9,999 kVAR<\/li>\n<li>Reactive power \u2014 Resolution: 0,001 kVAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b12% \u00b130 digits (&gt;20V and &gt;20 A) \/ \u00b13% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Reactive power \u2014 Measuring range: 10 &#8230; 99,99 kVAR<\/li>\n<li>Reactive power \u2014 Resolution: 0,01 kVAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b12% \u00b130 digits (&gt;20V and &gt;20 A) \/ \u00b13% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Reactive power \u2014 Measuring range: 100 &#8230; 999,9 kVAR<\/li>\n<li>Reactive power \u2014 Resolution: 0,1 kVAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b12% \u00b130 digits (&gt;20V and &gt;20 A) \/ \u00b13% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Reactive power \u2014 Measuring range: 1000 &#8230; 9999 kVAR<\/li>\n<li>Reactive power \u2014 Resolution: 1 kVAR<\/li>\n<li>Reactive power \u2014 Accuracy: \u00b12% \u00b130 digits (&gt;20V and &gt;20 A) \/ \u00b13% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Phase angle \u2014 Measuring range: -180 &#8230; +180 \u00b0<\/li>\n<li>Phase angle \u2014 Resolution: 0,1 \u00b0<\/li>\n<li>Phase angle \u2014 Accuracy: \u00b11 \u00b0<\/li>\n<li>Phase angle \u2014 Measuring range: 0 &#8230; 360 \u00b0<\/li>\n<li>Phase angle \u2014 Resolution: 0,1 \u00b0<\/li>\n<li>Phase angle \u2014 Accuracy: \u00b11\u00b0<\/li>\n<li>Apparent power \u2014 Measuring range: 10 &#8230; 999,9 VA<\/li>\n<li>Apparent power \u2014 Resolution: 0,1 VA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Apparent power \u2014 Measuring range: 1 &#8230; 9,999 kVA<\/li>\n<li>Apparent power \u2014 Resolution: 0,001 kVA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Apparent power \u2014 Measuring range: 10 &#8230; 99,99 kVA<\/li>\n<li>Apparent power \u2014 Resolution: 0,01 kVA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Apparent power \u2014 Measuring range: 100 &#8230; 999,9 kVA<\/li>\n<li>Apparent power \u2014 Resolution: 0,1 kVA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Apparent power \u2014 Measuring range: 1000 &#8230; 9999 kVA<\/li>\n<li>Apparent power \u2014 Resolution: 1 kVA<\/li>\n<li>Apparent power \u2014 Accuracy: \u00b11% \u00b120 digits (&gt;20V and &gt;20 A) \/ \u00b12% \u00b140 digits (&lt;20V &lt;20 A)<\/li>\n<li>Power factor \u2014 Measuring range: 0 &#8230; 1<\/li>\n<li>Power factor \u2014 Resolution: 0.001<\/li>\n<li>Power factor \u2014 Accuracy: \u00b10.04 (&gt;20 V and &gt;20 A) \/ \u00b10.1 (&lt;20 V and &lt;20 A)<\/li>\n<li>Active energy \u2014 Measuring range: 0 Wh &#8230; 999,999 kVArh<\/li>\n<li>Active energy \u2014 Resolution: 20 Digits<\/li>\n<li>Active energy \u2014 Accuracy: \u00b11% of Rd<\/li>\n<li>Apparent energy \u2014 Measuring range: 0 VAh &#8230; 999,999 kVAh<\/li>\n<li>Apparent energy \u2014 Resolution: 20 Digits<\/li>\n<li>Apparent energy \u2014 Accuracy: \u00b11% of Rd<\/li>\n<li>Reactive energy \u2014 Measuring range: 0 varh &#8230; 999,999 kVArh<\/li>\n<li>Reactive energy \u2014 Resolution: 20 Digits<\/li>\n<li>Reactive energy \u2014 Accuracy: \u00b11% of Rd<\/li>\n<li>Frequency \u2014 Measuring range: 46 &#8230; 65 Hz<\/li>\n<li>Frequency \u2014 Resolution: 0,1 Hz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b10.3 Hz<\/li>\n<li>Harmonic measurement (harmonics) \u2014 Measuring range: 1 &#8230; 50 (ordinal number)<\/li>\n<li>General technical data \u2014 Measuring functions: HOLD<\/li>\n<li>General technical data \u2014 Frequency: 50 &#8230; 60 Hz<\/li>\n<li>General technical data \u2014 Display type: LCD graphic display with backlight<\/li>\n<li>General technical data \u2014 Display size: 2 Inch<\/li>\n<li>Storage medium Internal memory \u2014 Storage capacity: 50000 Data records<\/li>\n<li>Storage medium Internal memory \u2014 Interface: USB<\/li>\n<li>Storage medium Internal memory: Standard(s)EN 61010-2-032<\/li>\n<li>Storage medium Internal memory: Maximum cable diameter 55 mm<\/li>\n<li>Storage medium Internal memory: Automatic power-off 15 min<\/li>\n<li>Storage medium Internal memory: Safety standard CAT III 600V<\/li>\n<li>Storage medium Internal memory \u2014 Dimensions: Current clamp opening: max. 55 mm<\/li>\n<li>Storage medium Internal memory \u2014 Measuring range: selection Automatic<\/li>\n<li>Storage medium Internal memory \u2014 Menu language: English, English (GB)<\/li>\n<li>Storage medium Internal memory \u2014 Protection class (device): IP20<\/li>\n<li>Storage medium Internal memory \u2014 (Rechargeable) battery: 2 x 1,5 V AA battery , Alkali-manganese<\/li>\n<li>Storage medium Internal memory \u2014 Capacity: 3000 mAh<\/li>\n<li>Storage medium Internal memory \u2014 Operating conditions: -10 &#8230; 50 \u00b0C , 0 &#8230; 85 % RH<\/li>\n<li>Storage medium Internal memory \u2014 Storage conditions: -10 &#8230; 50 \u00b0C , 0 &#8230; 85 % RH<\/li>\n<li>Storage medium Internal memory \u2014 Dimensions: ( L x W x H )271 x 112 x 46 mm<\/li>\n<li>Storage medium Internal memory \u2014 Weight: 650 g<\/li>\n<\/ul>\n<h3>Delivery scope<\/h3>\n<ul>\n<li>1 x Three-Phase Power Meter PCE-GPA 62<\/li>\n<li>2 x Isolated measuring pins with 2 m \/ 6.6 ft of cable each<\/li>\n<li>2 x Batteries<\/li>\n<li>1 x Carrying case<\/li>\n<li>1 x USB cable for a PC<\/li>\n<li>1 x Software (in English)<\/li>\n<li>1 x User&#8217;s manual<\/li>\n<\/ul>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-f6629d2f59a4feeb5.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=6689863&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Power Meter PCE-GPA 62 with network analyzer \/ Power and energy meter (real time) with data logger, graphic display, interface for PC and software. The One-Phase Digital Multimeter (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50\u00ba of the harmonic waveform.<\/p>\n","protected":false},"featured_media":48961,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1004],"product_tag":[],"class_list":["post-49567","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-energy-consumption-meter","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/49567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/48961"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=49567"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=49567"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=49567"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=49567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}