{"id":49499,"date":"2026-10-16T15:34:22","date_gmt":"2026-10-16T15:34:22","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-instruments-pce-dm-7-digitaalne-multimeeter\/"},"modified":"2026-10-16T20:04:14","modified_gmt":"2026-10-16T20:04:14","slug":"pce-instruments-pce-dm-7-digitaalne-multimeeter","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-instruments-pce-dm-7-digitaalne-multimeeter\/","title":{"rendered":"PCE Instruments PCE-DM 7 digital multimeter"},"content":{"rendered":"<p>Digital Multimeter \/ true RMS measurement \/ temperature measurement \/ automatic and manual measurement range selection \/ simple operation \/ bar graph display<\/p>\n<p>The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Digital Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).<\/p>\n<p>The device enables both automatic and manual measurement range selection and is equipped with an easy-to-read 2.8-inch LCD with backlight. With a sampling rate of three measurements per second, it delivers quick results and switches off automatically after five minutes of inactivity to extend the battery life. In addition, the Digital Multimeter offers a dual display: a bar graph for quick visual assessments and a numerical display for precise readings.<\/p>\n<p>The Digital Multimeter is powered by two 1.5 V batteries and is designed for easy one-handed operation. The compact dimensions of 140 x 70 x 35 mm make the Digital Multimeter a practical tool for everyday use by electricians and hardware developers as well as in other technical applications.<\/p>\n<h3>Highlights<\/h3>\n<ul>\n<li>non-contact voltage detection<\/li>\n<li>temperature measurement<\/li>\n<li>automatic power off<\/li>\n<li>automatic and manual measurement range selection<\/li>\n<li>hold function<\/li>\n<li>2.8-inch LC display with backlight<\/li>\n<li>small and compact design<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<ul>\n<li>Direct voltage DC \u2014 Measuring range: 0 &#8230; 9,999 mV<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,001 mV<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 10 &#8230; 99,99 mV<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,01 mV<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 100 &#8230; 999,9 mV<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,1 mV<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 1 &#8230; 9,999 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,001 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 10 &#8230; 99,99 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,01 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct voltage DC \u2014 Measuring range: 100 &#8230; 999,9 V<\/li>\n<li>Direct voltage DC \u2014 Resolution: 0,1 V<\/li>\n<li>Direct voltage DC \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 0 &#8230; 9999 \u00b5A<\/li>\n<li>Direct current DC \u2014 Resolution: 1 \u00b5A<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(0.8 % of Rd +3 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 10 &#8230; 99,99 mA<\/li>\n<li>Direct current DC \u2014 Resolution: 0,01 mA<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(0.8 % of Rd +3 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 100 &#8230; 999,9 mA<\/li>\n<li>Direct current DC \u2014 Resolution: 0,1 mA<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>Direct current DC \u2014 Measuring range: 1 &#8230; 9,999 A<\/li>\n<li>Direct current DC \u2014 Resolution: 0,001 A<\/li>\n<li>Direct current DC \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 0 &#8230; 9,999 nF<\/li>\n<li>Capacity \u2014 Resolution: 0,001 nF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(5.0 % of Rd +20 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 10 &#8230; 99,99 nF<\/li>\n<li>Capacity \u2014 Resolution: 0,01 nF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.0 % of Rd +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 100 &#8230; 999,9 nF<\/li>\n<li>Capacity \u2014 Resolution: 0,1 nF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.0 % of Rd +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 1 &#8230; 9,999 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,001 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.0 % of Rd +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 10 &#8230; 99,99 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,01 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.0 % of Rd +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 100 &#8230; 999,9 \u00b5F<\/li>\n<li>Capacity \u2014 Resolution: 0,1 \u00b5F<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(2.0 % of Rd +5 digits)<\/li>\n<li>Capacity \u2014 Measuring range: 1 &#8230; 9,999 mF<\/li>\n<li>Capacity \u2014 Resolution: 0,001 mF<\/li>\n<li>Capacity \u2014 Accuracy: \u00b1(5.0 % of Rd +5 digits)<\/li>\n<li>AC voltage \u2014 Measuring range: 0 &#8230; 9,999 mV<\/li>\n<li>AC voltage \u2014 Resolution: 0,001 mV<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 10 &#8230; 99,99 mV<\/li>\n<li>AC voltage \u2014 Resolution: 0,01 mV<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 100 &#8230; 999,9 mV<\/li>\n<li>AC voltage \u2014 Resolution: 0,1 mV<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 1 &#8230; 9,999 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,001 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 10 &#8230; 99,99 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,01 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>AC voltage \u2014 Measuring range: 100 &#8230; 750 V<\/li>\n<li>AC voltage \u2014 Resolution: 0,1 V<\/li>\n<li>AC voltage \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>AC voltage \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 0 &#8230; 9999 \u00b5A<\/li>\n<li>Alternating current AC \u2014 Resolution: 1 \u00b5A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 10 &#8230; 99,99 mA<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,01 mA<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 100 &#8230; 999,9 mA<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,1 mA<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1.2 % of Rd +3 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>Alternating current AC \u2014 Measuring range: 1 &#8230; 9,999 A<\/li>\n<li>Alternating current AC \u2014 Resolution: 0,001 A<\/li>\n<li>Alternating current AC \u2014 Accuracy: \u00b1(1.2 % of Rd +3 digits)<\/li>\n<li>Alternating current AC \u2014 Frequency: range 40 &#8230; 1000 Hz<\/li>\n<li>Resistance \u2014 Measuring range: 0 &#8230; 99,99 \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,01 \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1% of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 100 &#8230; 999,9 \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,1 \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 1 &#8230; 9,999 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,001 k\u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 10 &#8230; 99,99 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,01 k\u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 100 &#8230; 999,9 k\u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,1 k\u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(0.5 % of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 1 &#8230; 9,999 M \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,001 M \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(1.5 % of Rd +3 digits)<\/li>\n<li>Resistance \u2014 Measuring range: 10 &#8230; 99,99 M \u03a9<\/li>\n<li>Resistance \u2014 Resolution: 0,01 M \u03a9<\/li>\n<li>Resistance \u2014 Accuracy: \u00b1(3.0 % of Rd +5 digits)<\/li>\n<li>Duty cycle \u2014 Measuring range: 1 &#8230; 99 %<\/li>\n<li>Duty cycle \u2014 Resolution: 0,1 %<\/li>\n<li>Duty cycle \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 0 &#8230; 99,99 Hz<\/li>\n<li>Frequency \u2014 Resolution: 0,01 Hz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 100 &#8230; 999,9 Hz<\/li>\n<li>Frequency \u2014 Resolution: 0,1 Hz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 1 &#8230; 9,999 kHz<\/li>\n<li>Frequency \u2014 Resolution: 0,001 kHz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 10 &#8230; 99,99 kHz<\/li>\n<li>Frequency \u2014 Resolution: 0,01 kHz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 100 &#8230; 999,9 kHz<\/li>\n<li>Frequency \u2014 Resolution: 0,1 kHz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Frequency \u2014 Measuring range: 1 &#8230; 5 MHz<\/li>\n<li>Frequency \u2014 Resolution: 0,001 MHz<\/li>\n<li>Frequency \u2014 Accuracy: \u00b1(0.1 % of Rd +2 digits)<\/li>\n<li>Temperature \u2014 Measuring range: -20 &#8230; +1000 \u00b0C<\/li>\n<li>Temperature \u2014 Resolution: 1 \u00b0C<\/li>\n<li>Temperature \u2014 Accuracy: \u00b1(2.5 % of Rd +5 digits)<\/li>\n<li>Temperature \u2014 Measuring range: -4 &#8230; +1832 \u00b0F<\/li>\n<li>Temperature \u2014 Resolution: 1 \u00b0F<\/li>\n<li>Temperature \u2014 Accuracy: \u00b1(2.5 % of Rd +5 digits)<\/li>\n<li>General technical data \u2014 Measuring functions: HOLD<\/li>\n<li>General technical data \u2014 Display type: LCD with backlight<\/li>\n<li>General technical data \u2014 Display size: 2,8 Inch<\/li>\n<li>General technical data: Measuring rate 3 x per second<\/li>\n<li>General technical data: Automatic power-off 5 min<\/li>\n<li>General technical data: Safety standard CAT II 1000V, CAT III 600V<\/li>\n<li>General technical data \u2014 Measuring range: selection Automatic, Manual<\/li>\n<li>General technical data \u2014 Menu language: English, English (GB)<\/li>\n<li>General technical data \u2014 Protection class (device): IP20<\/li>\n<li>General technical data \u2014 (Rechargeable) battery: 2 x 1,5 V AA battery , Alkali-manganese<\/li>\n<li>General technical data \u2014 Capacity: 3000 mAh<\/li>\n<li>General technical data \u2014 Operating conditions: 0 &#8230; 40 \u00b0C , 0 &#8230; 75 % RH<\/li>\n<li>General technical data \u2014 Storage conditions: -20 &#8230; 60 \u00b0C , 0 &#8230; 80 % RH<\/li>\n<li>General technical data \u2014 Dimensions: ( L x W x H )140 x 70 x 35 mm<\/li>\n<li>General technical data \u2014 Weight: 175 g<\/li>\n<\/ul>\n<h3>Delivery scope<\/h3>\n<ul>\n<li>1 x Digital Multimeter PCE-DM 7<\/li>\n<li>1 x temperature sensor<\/li>\n<li>1 x test leads<\/li>\n<li>2 x 1.5 V AA battery<\/li>\n<li>1 x user manual<\/li>\n<li>1 x storage bag<\/li>\n<\/ul>\n<h3>Documents<\/h3>\n<ul>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-d671fa8d65c3aa0e4.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/pim.pce-service.net\/upload\/files\/assets\/pce-instruments-l66fa92c42c9a1d8a.pdf\">Supplier document<\/a><\/li>\n<li><a href=\"https:\/\/www.pce-instruments.com\/eu\/api\/getartfile?_fnr=3463243&amp;_dsp=inline\">Supplier document<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Digital Multimeter \/ true RMS measurement \/ temperature measurement \/ automatic and manual measurement range selection \/ simple operation \/ bar graph display. The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature.<\/p>\n","protected":false},"featured_media":48870,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1003],"product_tag":[],"class_list":["post-49499","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-digital-multimeters","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/49499","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/48870"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=49499"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=49499"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=49499"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=49499"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}