{"id":45455,"date":"2026-06-17T09:52:23","date_gmt":"2026-06-17T09:52:23","guid":{"rendered":"https:\/\/proair.ee\/toode\/ttk-350-s70l-h-490m3-h-construction-dehumidifier\/"},"modified":"2026-06-17T09:52:23","modified_gmt":"2026-06-17T09:52:23","slug":"ttk-350-s70l-h-490m3-h-construction-dehumidifier","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/ttk-350-s70l-h-490m3-h-construction-dehumidifier\/","title":{"rendered":"TTK 350 S70l\/h 490m3\/h Construction Dehumidifier"},"content":{"rendered":"<h2>TTK 350 S Construction Dehumidifier<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-26966\" src=\"http:\/\/proair.ee\/wp-content\/uploads\/2023\/02\/ttk-350-s-gewerbe-luftentfeuchter-8197-1024x239.jpg\" alt=\"Construction Dryer\" width=\"1024\" height=\"239\"><\/p>\n<div id=\"c1751937\" class=\"csc-default ctype-gridelements_pi1\">\n<div class=\"grid \">\n<div class=\"column column-2 col-lg-6 v-centered\">\n<div id=\"c1751936\" class=\"csc-default ctype-text\">\n<div class=\"csc-header csc-header-n1\">\n<h2 class=\"csc-firstHeader\">A robust and powerful all-purpose device<\/h2>\n<\/div>\n<p class=\"bodytext\">Black and white combined in one powerful machine. The TTK 350 S puts an end to the black-and-white choice between quality and affordability. It\u2019s both in one, so you can benefit from Far East prices without sacrificing build quality or reliability. After all, the quality of this air dryer is no accident\u2014it comes from traditional EU manufacturing.   <\/p>\n<p class=\"bodytext\">This high-performance construction dehumidifier can dry rooms up to 180 m\u00b2 in size, with a dehumidification capacity of up to 70 liters in 24 hours. The desired humidity level can be set within a range of 32% to 100% relative humidity. Using the convenient rotary switch, the TTK 350 S operates fully automatically thanks to the hygrostat. In addition, it generates a powerful air circulation of 1,000 cubic meters per hour.   <\/p>\n<p class=\"bodytext\">The fact that this reliable air dryer is designed to be sturdy and durable is evident not only in its plastic-coated metal housing but also in its stable cart design, complete with a handle and large transport wheels, which ensure maximum mobility.<\/p>\n\n<h3>Steady-state mode for construction drying<\/h3>\n<p class=\"bodytext\">Thanks to the option of connecting an external condensate drain\u2014using an optional condensate pump if necessary\u2014<b> <\/b> \u2019s TTK 350 S is also ideal for longer, unattended drying jobs, such as drying out buildings.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"c1751934\" class=\"csc-default ctype-gridelements_pi1\">\n<div class=\"grid \">\n<div class=\"column column-1 col-lg-6 v-centered\">\n<div id=\"c1751933\" class=\"csc-default ctype-text\">\n<div class=\"csc-header csc-header-n1\">\n<h2 class=\"csc-firstHeader\">Performance and safety are very important here!<\/h2>\n<\/div>\n<p class=\"bodytext\">The power switch and level warning light are protected from dust and splashing water by a protective cover, and the slotted hygrostat rotary switch prevents accidental adjustment of the switch position. The condensate tank indicator light comes on when the condensate tank is full. In addition, the TTK 350 S automatically shuts off when the water tank is full.  <\/p>\n<p class=\"bodytext\">It features a professional automatic hot-gas defrosting system that ensures efficient drying results even at low temperatures, and thanks to its standard external condensate drain, the TTK 350 S is also suitable for longer, unattended continuous drying operations and for drying buildings.<\/p>\n<p class=\"bodytext\">The TTK 350 S is available exclusively from Trotec and can be optionally equipped with an <b>integrated<\/b> operating hours counter or <b>a MID-compliant dual counter<\/b> for operating hours and kilowatt-hours.<\/p>\n<\/div>\n<div id=\"c1760326\" class=\"box-white csc-default clearfix ctype-text\">\n<p class=\"bodytext\"><b>What does &#8220;MID-compatible&#8221; mean?<\/b><\/p>\n<p class=\"bodytext\">The European Measuring Instruments Directive (MID) replaces the previous regulations on national approval and subsequent calibration in certain areas. As a result, all energy meters used in Europe for billing energy consumption must be MID-compliant in the future. <\/p>\n<table id=\"t063646ab7185a3\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Moisture Removal Performance<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">at 30 \u00b0C \/ 80% RH [l\/24h]<\/th>\n<td width=\"40%\">55<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">max [l\/24h]<\/th>\n<td width=\"40%\">70<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">air volume<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Max. flow rate [m\u00b3\/h]<\/th>\n<td width=\"40%\">490<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Recommended room size for dry storage<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">m\u00b3<\/th>\n<td width=\"40%\">450<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">m\u00b2<\/th>\n<td width=\"40%\">180<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Environmental Conditions<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Temperature range, min [\u00b0C]<\/th>\n<td width=\"40%\">5<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Maximum temperature range [\u00b0C]<\/th>\n<td width=\"40%\">32<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Humidity range min [% RH]<\/th>\n<td width=\"40%\">50<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Maximum humidity range [% RH]<\/th>\n<td width=\"40%\">90<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">electrical values<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Power connection<\/th>\n<td width=\"40%\">220\u2013240 V\/50 Hz<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Rated Current [A]<\/th>\n<td width=\"40%\">6.1<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Power consumption [kW]<\/th>\n<td width=\"40%\">1.4<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Recommended protection [A]<\/th>\n<td width=\"40%\">10<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">electrical connection<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">plug plug<\/th>\n<td width=\"40%\">CEE 7\/7<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">cable length [m]<\/th>\n<td width=\"40%\">3<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">compressor<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">rotary piston compressor<\/th>\n<td width=\"40%\">+<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">piston compressor<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Refrigerant type<\/th>\n<td width=\"40%\">R-454C<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Amount of refrigerant [g]<\/th>\n<td width=\"40%\">650<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">GWP factor<\/th>\n<td width=\"40%\">146<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">CO <sub>\u2082<\/sub> equivalent<\/th>\n<td width=\"40%\">0.0949<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Suction Side Pressure [MPa]<\/th>\n<td width=\"40%\">0.6<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Pressure on the outlet side [MPa]<\/th>\n<td width=\"40%\">2.2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Maximum Allowable Pressure [MPa]<\/th>\n<td width=\"40%\">3<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">water tank<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Volume [in liters]<\/th>\n<td width=\"40%\">6<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">sound levels<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Distance 1 m [dB(A)]<\/th>\n<td width=\"40%\">54<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Features and Equipment<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Power indicator light<\/th>\n<td width=\"40%\">+<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">room temperature sensor<\/th>\n<td width=\"40%\">+<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">memory function<\/th>\n<td width=\"40%\">+<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Drain<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"csc-header csc-header-n1\">\n<h3 class=\"csc-firstHeader\">TTK 350 S Construction Dehumidifier<\/h3>\n<\/div>\n<p class=\"bodytext\">Black and white combined in one powerful machine. The TTK 350 S puts an end to the black-and-white choice between quality and affordability. It\u2019s both in one, so you can benefit from Far East prices without sacrificing build quality or reliability. After all, the quality of this air dryer is no accident\u2014it comes from traditional EU manufacturing.   <\/p>\n","protected":false},"featured_media":45457,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"TTK 350 S Construction Dehumidifier","_seopress_titles_desc":"TTK 350 S Construction Dehumidifier: A wide selection of construction dehumidifiers from Pro Air O\u00dc.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[],"product_cat":[934,1311],"product_tag":[],"class_list":["post-45455","product","type-product","status-publish","has-post-thumbnail","product_cat-construction-dryer","product_cat-trotec-construction-dehumidifiers-germany","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/45455","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/45457"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=45455"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=45455"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=45455"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=45455"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}