{"id":45032,"date":"2026-06-17T09:47:04","date_gmt":"2026-06-17T09:47:04","guid":{"rendered":"https:\/\/proair.ee\/toode\/tfv-100-centrifugal-fan\/"},"modified":"2026-06-17T09:47:04","modified_gmt":"2026-06-17T09:47:04","slug":"tfv-100-centrifugal-fan","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/tfv-100-centrifugal-fan\/","title":{"rendered":"TFV 100 Centrifugal Fan"},"content":{"rendered":"<h2 class=\"mb-1 text-lg font-bold text-black tracking-normal title-font\">TFV 100 Centrifugal Fan<\/h2>\n<p>&nbsp;<\/p>\n<div class=\"columns\">\n<div class=\"column main\">\n<div class=\"product-info-main\">\n<div class=\"column-info\">\n<section>\n<div id=\"product-tabs\" class=\"py-6\">\n<div class=\"border border-gray-lighter md:border-0\">\n<div id=\"tab-description\" class=\"description-tab-product p-4 border-gray-lighter md:border md:border-t-0\">\n<p>Proper ventilation is not only important for a pleasant working environment, but is also essential in many areas for occupational safety reasons and in accordance with official regulations.<\/p>\n<p><a href=\"http:\/\/proair.ee\/wp-content\/uploads\/2022\/02\/tfv-100-radialventilator-08cf.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-20788\" src=\"http:\/\/proair.ee\/wp-content\/uploads\/2022\/02\/tfv-100-radialventilator-08cf-1024x239.jpg\" alt=\"Trotec Radial Fan\" width=\"1024\" height=\"239\"><\/a><\/p>\n<p>Ventilating rooms removes harmful substances such as paint and varnish fumes, welding fumes, dust particles, carbon monoxide, nitrogen oxides, carbon dioxide, and water vapor.<\/p>\n<p>The TFV 100 high-pressure centrifugal fan is well-suited for such tasks, as it delivers up to 4,000 m\u00b3\/h of air even over long distances with high back pressure and remains extremely stable in harsh operating conditions.<\/p>\n<p>Since this fan draws in air axially and expels it radially, it is not only effective at handling heavily contaminated air with high dust content, but also ensures high and stable performance curves.<\/p>\n<p>In addition to the standard version, the TFV 100 fan is also available as a rental version.<\/p>\n<p><a href=\"http:\/\/proair.ee\/wp-content\/uploads\/2022\/02\/mobile-ventilatoren-der-tfv-serie-6835.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-20755\" src=\"http:\/\/proair.ee\/wp-content\/uploads\/2022\/02\/mobile-ventilatoren-der-tfv-serie-6835-1024x239.jpg\" alt=\"Centrifugal fan for industrial use\" width=\"1024\" height=\"239\"><\/a><\/p>\n<p><strong>Here are a few of the practical advantages of the TFV 100, in brief:<\/strong><\/p>\n<ul>\n<li>An exceptionally sturdy device with a high load capacity<\/li>\n<li>Splash-proof version (IP55)<\/li>\n<li>Can also be used in very dusty rooms<\/li>\n<li>The fan motor is located outside the main airflow<\/li>\n<li>Can be connected to both intake and exhaust ducts<\/li>\n<li>stable regions of the characteristic curve and consistently high pressure<\/li>\n<\/ul>\n<p><strong>Here is an overview of the TFV 100&#8217;s technical specifications:<\/strong><\/p>\n<ul>\n<li>Free-flow air volume: 4,000 m\u00b3\/h<\/li>\n<li>Air discharge velocity: 17 m\/s (61.2 km\/h)<\/li>\n<li>Fan speeds: 1<\/li>\n<li>maximum air pressure*: 2020 Pa<\/li>\n<li>Maximum transmission medium temperature: 80 \u00b0C<\/li>\n<li>Environmental conditions: -20 \u00b0C to 40 \u00b0C<\/li>\n<li>Mains voltage: 400 V \/ 50 Hz (7.8 A)<\/li>\n<li>Power connection: CEE 16 A<\/li>\n<li>Power consumption: 2.2 kW<\/li>\n<li>Inlet connection: accessories (\u00f8 300 mm)<\/li>\n<li>Discharge nozzle: series (\u00f8 300 mm)<\/li>\n<li>Sound level (at a distance of 1.5 m): 87.5 dB(A)<\/li>\n<li>Body: steel, powder-coated, 2K paint<\/li>\n<li>Dimensions (including frame): 1008 x 670 x 1070 mm<\/li>\n<li>Weight: 120 kg<\/li>\n<\/ul>\n<p><em>*At 20 \u00b0C, 500 m above sea level (NN)<\/em><\/p>\n<p><strong><em>The photo shows the TFV 100 installed in a frame. It is not included in the package and is available upon request. <\/em><\/strong><\/p>\n<p class=\"mb-1 text-lg font-bold text-black tracking-normal title-font\">Frame for the TFV 100 \u2014 price: 1,259 euros, including VAT.<\/p>\n<table id=\"t0611ebfdc03436\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Air volume<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Max \u2013 free outlet [m\u00b3\/h]<\/th>\n<td width=\"40%\">4,000<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">air volume at atmospheric pressure<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">m\u00b3\/h<\/th>\n<td width=\"40%\">2000<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Pa<\/th>\n<td width=\"40%\">2020<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">airflow<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">while blowing out<\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">sucking<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">air discharge velocity<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Ms.<\/th>\n<td width=\"40%\">17<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">km\/h<\/th>\n<td width=\"40%\">61.2<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Fan<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">fan speeds<\/th>\n<td width=\"40%\">1<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">air pressure<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Maximum Level [Pa]<\/th>\n<td width=\"40%\">2080<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">conveyor temperature<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">maximum [\u00b0C]<\/th>\n<td width=\"40%\">80<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Environmental Conditions<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Temperature range min [\u00b0C]<\/th>\n<td width=\"40%\">-20<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Maximum temperature range [\u00b0C]<\/th>\n<td width=\"40%\">40<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">security feature<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">IP Protection Class<\/th>\n<td width=\"40%\">55<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">electrical values<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Power connection<\/th>\n<td width=\"40%\">400 V\/50 Hz<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Power consumption [kW]<\/th>\n<td width=\"40%\">2.2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Recommended protection [A \/ motor protection switch]<\/th>\n<td width=\"40%\">10<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Rated Current [A]<\/th>\n<td width=\"40%\">7.8<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">electrical connection<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">plug plug<\/th>\n<td width=\"40%\">CEE 16 A<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">cable length [m]<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">hose connection<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Inlet manifold [mm]<\/th>\n<td width=\"40%\">300<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">outlet diameter [mm]<\/th>\n<td width=\"40%\">300<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">sound levels<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Distance 1 m [dB(A)]<\/th>\n<td width=\"40%\">87.5<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Distance 3 m [dB(A)]<\/th>\n<td width=\"40%\">81.5<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">explosion protection<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Zone<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">protection class<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">dimension<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Length (without packaging) [mm]<\/th>\n<td width=\"40%\">960<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Width (without packaging) [mm]<\/th>\n<td width=\"40%\">560<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Height (without packaging) [mm]<\/th>\n<td width=\"40%\">750<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Weight<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">(without packaging) [kg]<\/th>\n<td width=\"40%\">120<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"t1611ebfdc03436\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr class=\"titlerow\">\n<th class=\"color\" colspan=\"3\">EQUIPMENT, FEATURES, AND FUNCTIONS<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Body<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">Steel, powder-coated<\/th>\n<td width=\"40%\">+<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">plastic<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">metal<\/th>\n<td width=\"40%\">&#8211;<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">mobility<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">crane<\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\">forklift<\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section><\/section>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<footer class=\"page-footer\">\n<div class=\"footer content\">\n<div class=\"bg-white py-16 mx-auto\">\n<div class=\"wrapper flex flex-col flex-wrap md:flex-row\"><\/div>\n<\/div>\n<\/div>\n<\/footer>\n","protected":false},"excerpt":{"rendered":"<h3 class=\"mb-1 text-lg font-bold text-black tracking-normal title-font\">TFV 100 Centrifugal Fan<\/h3>\n<p>Proper ventilation is not only important for a pleasant working environment, but is also essential in many areas for occupational safety reasons and in accordance with official regulations.<\/p>\n","protected":false},"featured_media":45033,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"TFV 100 Centrifugal Fan","_seopress_titles_desc":"TFV 100 Centrifugal Fan Proper ventilation is important for the work environment and, in many areas, is essential for occupational safety reasons.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[],"product_cat":[1129,1147,1104,901],"product_tag":[1130,1465],"class_list":["post-45032","product","type-product","status-publish","has-post-thumbnail","product_cat-centrifugal-fans","product_cat-conveyor-fan","product_cat-high-performance-products","product_cat-industrial-commercial-fans-and-blowers","product_tag-centrifugal-fan","product_tag-radial-fan","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/45032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/45033"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=45032"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=45032"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=45032"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=45032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}