{"id":44663,"date":"2026-06-17T09:52:00","date_gmt":"2026-06-17T09:52:00","guid":{"rendered":"https:\/\/proair.ee\/toode\/trotec-be44-clamp-on-multimeter\/"},"modified":"2026-06-17T09:52:00","modified_gmt":"2026-06-17T09:52:00","slug":"trotec-be44-clamp-on-multimeter","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/trotec-be44-clamp-on-multimeter\/","title":{"rendered":"Trotec BE44 Clamp-On Multimeter"},"content":{"rendered":"<h2>Trotec BE44 Clamp-On Multimeter<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-25837\" src=\"http:\/\/proair.ee\/wp-content\/uploads\/2022\/10\/be44-stromzange-7ef8-1024x239.jpg\" alt=\"Trotec BE44 Clamp-On Multimeter\" width=\"1024\" height=\"239\"><\/p>\n<div id=\"c2575999\" class=\"csc-default ctype-text\">\n<p class=\"bodytext\"><span>With a sturdy clamp <\/span><span>ammeter<\/span><span> is a reliable and versatile measuring tool for both home users and electricians, craftsmen, and maintenance technicians. With this meter, you can quickly and easily measure AC voltages on electrical circuits without turning them off, or check DC circuits in cars, for example.<\/span><\/p>\n<p class=\"bodytext\"><span>With the compact BE44 current clamp, you\u2019re always safe when measuring AC voltages up to 750 volts. Since you use the current clamps to enclose the conductor, the measuring device detects the presence of voltage non-contact by measuring the electromagnetic field. This \u201cgalvanic isolation\u201d prevents direct contact with the circuit under test, allowing you to perform tests even on live systems.  <\/span><\/p>\n<\/div>\n<div id=\"c2575936\" class=\"csc-default ctype-text\">\n<p class=\"bodytext\">In addition, the test unit can measure current up to 1,000 A in both direct and alternating current and measure DC voltages up to 1,000 volts; both can be set either manually or using automatic range selection. Since this also allows for testing a car\u2019s DC electrical system, the BE44 current clamp, for example, is the ideal measuring tool for passionate car enthusiasts and automotive professionals. <\/p>\n<div id=\"c2576473\" class=\"csc-default ctype-text\">\n<div class=\"csc-header csc-header-n1\">\n<h3 class=\"csc-firstHeader\">A current clamp with equipment fit for a true professional<\/h3>\n<\/div>\n<p class=\"bodytext\">The BE44 has all the usual standard measurement functions, such as resistance, duty cycle, and frequency measurement, which you can easily select using the convenient rotary switch. You can view additional information on the LCD screen: The bar graph indicator shows how close you are to an electrical conductor or its electric field. <\/p>\n<p class=\"bodytext\">A diode tester and continuity test also allow for reliable testing of, for example, a vehicle&#8217;s electrical system.<\/p>\n<\/div>\n<div id=\"c2576251\" class=\"csc-default ctype-text\">\n<p class=\"bodytext\">All measurement results are displayed on a backlit 1.8-inch LCD screen. This clip-on ammeter also features functions such as the HOLD function, polarity and overload indicators, and a MIN\/MAX display. <\/p>\n<p class=\"bodytext\">In addition, the BE44 ensures trouble-free use thanks to its battery-saving automatic shut-off feature and screen that turns off when the battery is low, as well as an LED light integrated between the two jaws of the pliers, which allows for safe work even in poor lighting conditions. <\/p>\n<\/div>\n<h2 class=\"\">Advantages:<\/h2>\n<ul class=\"list-grid grid-md-4 csc-default csc-bulletlist-1-a\">\n<li class=\"column\">3 5\/6-digit LCD display (maximum display: 9999)<\/li>\n<li class=\"column\">Sturdy body<\/li>\n<li class=\"column\">CAT III 1000V \/ 750V<\/li>\n<li class=\"column\">AC measurement up to 1000 A<\/li>\n<li class=\"column\">DC current measurement up to 1000 A<\/li>\n<li class=\"column\">AC voltage measurement up to 750 V<\/li>\n<li class=\"column\">Measurement of DC voltage up to 1000 V<\/li>\n<li class=\"column\">Highest resolution in the milliamperes range<\/li>\n<li class=\"column\">Non-contact detection of alternating voltage<\/li>\n<li class=\"column\">resistance measurement<\/li>\n<li class=\"column\">Measuring the work cycle<\/li>\n<li class=\"column\">frequency measurement<\/li>\n<li class=\"column\">Continuity Test and Diode Test<\/li>\n<li class=\"column\">polarity indicator<\/li>\n<li class=\"column\">overload protection<\/li>\n<li class=\"column\">Battery low indicator<\/li>\n<li class=\"column\">Automatic and Manual Distance Measurement<\/li>\n<li class=\"column\">Measured Value Hold Function<\/li>\n<li class=\"column\">screen backlight<\/li>\n<li class=\"column\">Bar Chart Indicator<\/li>\n<li class=\"column\">LED with integrated white light for use in low-light conditions<\/li>\n<li class=\"column\">Suitable for cables with a diameter of up to 38 mm<\/li>\n<li class=\"column\">Battery-Saving Automatic Shut-Off<\/li>\n<li class=\"column\">Comes with a storage bag<\/li>\n<li class=\"column\">Optimal price-quality ratio<\/li>\n<\/ul>\n<table id=\"t062431dfd85112\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>DC voltage [V\/DC]<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range min [V]<\/span><\/th>\n<td width=\"40%\"><span>6<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Maximum measurement range [V]<\/span><\/th>\n<td width=\"40%\"><span>1000<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1 [%]<\/span><\/th>\n<td width=\"40%\"><span>0.8<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (6V\/60V\/600V)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(0.8% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (1000 V)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.0% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Direct Current [A\/DC]<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range min [A]<\/span><\/th>\n<td width=\"40%\"><span>60<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Maximum measurement range [A]<\/span><\/th>\n<td width=\"40%\"><span>1000<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1 [%]<\/span><\/th>\n<td width=\"40%\"><span>3<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (60A)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(3.0% + 10)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (600A\/1000A)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(3.0% + 6)<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Alternating Current [V\/AC]<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range min [V]<\/span><\/th>\n<td width=\"40%\"><span>6<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Maximum measurement range [V]<\/span><\/th>\n<td width=\"40%\"><span>750<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1 [%]<\/span><\/th>\n<td width=\"40%\"><span>1.2<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (6 V)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(0.8% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (60 V, 600 V, 750 V)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.2% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Alternating Current [A\/AC]<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range min [A]<\/span><\/th>\n<td width=\"40%\"><span>60<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Maximum measurement range [A]<\/span><\/th>\n<td width=\"40%\"><span>1000<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1 [%]<\/span><\/th>\n<td width=\"40%\"><span>2.5<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Maximum guide diameter [mm]<\/span><\/th>\n<td width=\"40%\"><span>38<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%]<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(2.5% + 6)<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>resistance [\u03a9]<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range [\u03a9] min.<\/span><\/th>\n<td width=\"40%\"><span>600<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement range [\u03a9] max.<\/span><\/th>\n<td width=\"40%\"><span>60 m<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1 [%]<\/span><\/th>\n<td width=\"40%\"><span>3<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (600\u03a9\/6k\u03a9\/60k\u03a9\/600k\u03a9)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.0% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (6 M\u03a9)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.5% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (60 M\u03a9)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(3.0% + 10)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%]<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.0% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (9.99 Hz\/99.99 Hz\/999.9 Hz\/9.999 kHz\/99.99 kHz\/999.9 kHz)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(1.0% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%]<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(2% + 7)<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Accuracy \u00b1[%] (40.00 nF\/400.0 nF\/4000 \u00b5F\/40.00 \u00b5F\/400.0 \u00b5F)<\/span><\/th>\n<td width=\"40%\"><span>\u00b1(5.0% + 5)<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>screen<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>LCD 3 5\/6 digits<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>residential design<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>plastic<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>interfaces<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Connectors for 4 mm safety plugs (banana plugs)<\/span><\/th>\n<td width=\"40%\"><span>2<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>measurement chain category<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>CAT III (1000 V)<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>security<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Compliance &#8211; Yes<\/span><\/th>\n<td width=\"40%\"><span>EN 61010-1, Pollution Degree 2<\/span><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Protection Level<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>IP20<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>power source<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>internal (battery)<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Environmental Conditions<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Operating \u2013 minimum temperature [\u00b0C]<\/span><\/th>\n<td width=\"40%\"><span>0<\/span><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Operating \u2013 maximum temperature [\u00b0C]<\/span><\/th>\n<td width=\"40%\"><span>40<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"t162431dfd85112\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr class=\"titlerow\">\n<th class=\"color\" colspan=\"3\"><span>STANDARD SCOPE OF DELIVERY<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Standard Scope of Delivery<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>gauge<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>battery(ies)<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>bag\/case<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Safety test leads with test probes<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>user manual<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"t262431dfd85112\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr class=\"titlerow\">\n<th class=\"color\" colspan=\"3\"><span>MEASURABLE QUANTITIES AND FUNCTIONS<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>internal sensors<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Alternating Current [V\/AC]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Direct current voltage [V\/DC]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>resistance [\u03a9]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Alternating Current [A\/AC]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Capacitance [nF, \u00b5F]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Frequency [Hz, kHz, MHz]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>duty cycle [%]<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\"><span>Features and Equipment<\/span><\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measured Value Hold Function<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>automatic range selection<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>The screen exceeds the measurement range<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>Measurement of direct current, alternating current, direct voltage, alternating voltage, capacitance, frequency, duty cycle, and resistance<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>automatic shut-off<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>backlit screen<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>diode test<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>consistency test<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>battery status indicator<\/span><\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\"><\/th>\n<th width=\"30%\"><span>integrated LED lamp<\/span><\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3>Trotec BE44 Clamp-On Multimeter<\/h3>\n<p>An ammeter with a sturdy clamp\u2014a reliable and versatile measuring tool for both home users and electricians, craftsmen, and maintenance technicians. With this meter, you can quickly and easily measure AC voltages on electrical circuits without turning them off, or check DC circuits in cars, for example. <\/p>\n","protected":false},"featured_media":44664,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"Trotec BE44 Clamp-On Multimeter","_seopress_titles_desc":"The Trotec BE44 clamp meter is a reliable and versatile measuring device for both home users and electricians, craftsmen, and maintenance technicians","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[],"product_cat":[1003,975],"product_tag":[1280],"class_list":["post-44663","product","type-product","status-publish","has-post-thumbnail","product_cat-digital-multimeters","product_cat-measuring-instruments","product_tag-digital-multimeter","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/44663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/44664"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=44663"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=44663"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=44663"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=44663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}