{"id":44645,"date":"2026-06-17T09:36:12","date_gmt":"2026-06-17T09:36:12","guid":{"rendered":"https:\/\/proair.ee\/toode\/trotec-bg40-sensitive-gas-detector\/"},"modified":"2026-09-01T07:29:59","modified_gmt":"2026-09-01T07:29:59","slug":"trotec-bg40-sensitive-gas-detector","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/trotec-bg40-sensitive-gas-detector\/","title":{"rendered":"Trotec BG40 Gas Detector \u2013 Gas Leak Detector, 0\u201310,000 ppm"},"content":{"rendered":"<div class=\"product-attribute short-description\">\n<h2 data-section-id=\"1yxwle5\" data-start=\"0\" data-end=\"72\">Trotec BG40 Gas Detector \u2013 for Rapid Detection of Combustible Gas Leaks<\/h2>\n<p data-start=\"74\" data-end=\"438\"><strong data-start=\"74\" data-end=\"89\">The Trotec BG40<\/strong> is <strong data-start=\"109\" data-end=\"150\">a<\/strong> professional <strong data-start=\"109\" data-end=\"150\">gas detector<\/strong> designed for the rapid localization of leaks of combustible and other sensitive gases. The device responds to changes in gas concentration <strong data-start=\"301\" data-end=\"316\">in<\/strong> as little as approximately <strong data-start=\"301\" data-end=\"316\">2 seconds<\/strong>; its measurement range is <strong data-start=\"334\" data-end=\"350\">0\u201310,000 ppm<\/strong>, and its sensitivity for methane is less than <strong data-start=\"389\" data-end=\"399\">10 ppm<\/strong>.<\/p>\n<p data-start=\"440\" data-end=\"655\">The BG40 combines the functions of a gas detector and an alarm device in a single unit. Upon detecting gas, the device alerts the user with <strong data-start=\"554\" data-end=\"599\">an audible, visual, and vibrating alarm<\/strong>, the intensity of which increases with rising gas concentration.<\/p>\n<p data-start=\"657\" data-end=\"868\">The 40-cm-long semi-flexible probe allows for inspection of hard-to-reach areas, such as pipe connections, areas behind gas appliances, and connection points in technical systems.<\/p>\n<h3 data-section-id=\"1igdtxn\" data-start=\"870\" data-end=\"906\">What is the Trotec BG40 used for?<\/h3>\n<p data-start=\"908\" data-end=\"993\">The BG40 is particularly well-suited for situations where <strong data-start=\"970\" data-end=\"992\">the location of a gas leak<\/strong> needs to be quickly identified.<\/p>\n<p data-start=\"995\" data-end=\"1156\">Typical applications include gas piping and connections, heating systems, boiler rooms, gas stoves, tanks, industrial equipment, utility rooms, and HVAC and maintenance work.<\/p>\n<p data-start=\"1158\" data-end=\"1355\">A key advantage of the device is that it not only signals the presence of gas with an alarm\u2014you can also monitor changes in concentration on the screen. This helps you move the probe closer and closer to the source of the leak.<\/p>\n<h3 data-section-id=\"1erwjsd\" data-start=\"1357\" data-end=\"1391\">What gases does the BG40 detect?<\/h3>\n<p data-start=\"1393\" data-end=\"1497\">BG40 standardkalibreering on tehtud <strong data-start=\"1429\" data-end=\"1442\">metaanile<\/strong>, kuid andur reageerib paljudele gaasidele ja aurudele.<\/p>\n<p data-start=\"1499\" data-end=\"1565\">Troteci kasutusjuhend nimetab tuvastatavate ainete hulgas n\u00e4iteks:<\/p>\n<p data-start=\"1567\" data-end=\"1827\"><strong data-start=\"1567\" data-end=\"1789\">natural gas, methane, ethane, ethylene, propane, isobutane, hexane, benzene, ethanol, formaldehyde, acetaldehyde, toluene, p-xylene, ammonia, hydrogen, hydrogen sulfide, gasoline vapors, industrial solvents, and paint thinners.<\/strong><\/p>\n<p data-start=\"1829\" data-end=\"1958\">The sensor may also react to other substances listed, so the BG40 is not intended for determining the chemical composition of unknown gases.<\/p>\n<h3 data-section-id=\"176cp4a\" data-start=\"1960\" data-end=\"2006\">Detecting a gas leak in just a few seconds<\/h3>\n<p data-start=\"2008\" data-end=\"2056\">The BG40 has a response time of approximately <strong data-start=\"2041\" data-end=\"2055\">2 seconds<\/strong>.<\/p>\n<p data-start=\"2058\" data-end=\"2240\">This is useful for locating leaks: the probe can be moved along the piping and at connection points to monitor changes in the alarm frequency and reading.<\/p>\n<h3 data-section-id=\"1hgf022\" data-start=\"2242\" data-end=\"2274\">Measurement range up to 10,000 ppm<\/h3>\n<p data-start=\"2276\" data-end=\"2297\">The BG40&#8217;s measurement range is:<\/p>\n<p data-start=\"2299\" data-end=\"2315\"><strong data-start=\"2299\" data-end=\"2315\">0\u201310,000 ppm<\/strong><\/p>\n<p data-start=\"2317\" data-end=\"2350\">and for methane, the sensitivity is:<\/p>\n<p data-start=\"2352\" data-end=\"2364\"><strong data-start=\"2352\" data-end=\"2364\">&lt;10 ppm.<\/strong><\/p>\n<p data-start=\"2366\" data-end=\"2507\">The device has two sensitivity levels, which allow the measurement to be adjusted according to the gas concentration.<\/p>\n<h3 data-section-id=\"1lydevh\" data-start=\"2509\" data-end=\"2553\">Audible, visual, and vibration alarms<\/h3>\n<p data-start=\"2555\" data-end=\"2625\">When gas is detected, the BG40 can alert the user in several ways at once:<\/p>\n<p data-start=\"2627\" data-end=\"2694\"><strong data-start=\"2627\" data-end=\"2645\">with an audible signal<\/strong>,<br data-start=\"2646\" data-end=\"2649\"\/><strong data-start=\"2649\" data-end=\"2671\">with a visual alarm<\/strong>,<br data-start=\"2672\" data-end=\"2675\"\/><strong data-start=\"2675\" data-end=\"2693\">with vibration<\/strong>.<\/p>\n<p data-start=\"2696\" data-end=\"2850\">The alarm frequency depends on the measured gas concentration\u2014the higher the concentration, the faster the alarm is triggered.<\/p>\n<p data-start=\"2852\" data-end=\"2932\">This makes it easier to locate the source of a leak, even in a noisy technical environment.<\/p>\n<h3 data-section-id=\"1qo4563\" data-start=\"2934\" data-end=\"2956\">40 cm flexible probe<\/h3>\n<p data-start=\"2958\" data-end=\"3038\">One of the BG40&#8217;s most practical features is its <strong data-start=\"2993\" data-end=\"3037\">400-mm-long semi-flexible gooseneck probe<\/strong>.<\/p>\n<p data-start=\"3040\" data-end=\"3247\">The probe can be directed, for example, behind pipes, near gas appliance connections, into narrow shafts, or to other locations where it is not possible to place the measuring device itself.<\/p>\n<h3 data-section-id=\"11fjvdf\" data-start=\"3249\" data-end=\"3268\">Large LCD screen<\/h3>\n<p data-start=\"3270\" data-end=\"3338\">The BG40 features an easy-to-read LCD screen with an additional indicator scale.<\/p>\n<p data-start=\"3340\" data-end=\"3511\">The display shows, among other things, gas concentration, sensitivity level, alarm status, vibration, battery status, and other operating mode indicators.<\/p>\n<h3 data-section-id=\"d72jcl\" data-start=\"3513\" data-end=\"3552\">AutoZero and Zero Point Calibration<\/h3>\n<p data-start=\"3554\" data-end=\"3646\">When searching for gas leaks, it is important that the measurement reference point reflect the surrounding conditions.<\/p>\n<p data-start=\"3648\" data-end=\"3840\">The BG40 features <strong data-start=\"3672\" data-end=\"3720\">an AutoZero function<\/strong>, which simplifies the detection of relative concentration changes during leak detection.<\/p>\n<h3 data-section-id=\"2b51ez\" data-start=\"3842\" data-end=\"3866\">Two sensitivity levels<\/h3>\n<p data-start=\"3868\" data-end=\"3916\">The BG40 allows you to choose between two measurement ranges.<\/p>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3918\" data-end=\"4055\">\n<thead data-start=\"3918\" data-end=\"3944\">\n<tr data-start=\"3918\" data-end=\"3944\">\n<th class=\"last:pe-10\" data-start=\"3918\" data-end=\"3927\" data-col-size=\"sm\">Mode<\/th>\n<th class=\"last:pe-10\" data-start=\"3927\" data-end=\"3944\" data-col-size=\"sm\">Measurement Range<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3956\" data-end=\"4055\">\n<tr data-start=\"3956\" data-end=\"4003\">\n<td data-start=\"3956\" data-end=\"3982\" data-col-size=\"sm\">Higher sensitivity \/ x10<\/td>\n<td data-start=\"3982\" data-end=\"4003\" data-col-size=\"sm\">up to <strong data-start=\"3989\" data-end=\"4001\">1,000 ppm<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4004\" data-end=\"4055\">\n<td data-start=\"4004\" data-end=\"4032\" data-col-size=\"sm\">Lower sensitivity \/ x100<\/td>\n<td data-start=\"4032\" data-end=\"4055\" data-col-size=\"sm\">up to <strong data-start=\"4039\" data-end=\"4053\">10,000 ppm<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"4057\" data-end=\"4239\">This helps first detect low gas concentrations and then continue to pinpoint the leak in areas with higher concentrations.<\/p>\n<h3 data-section-id=\"u1blqq\" data-start=\"4241\" data-end=\"4269\">Built-in Li-ion battery<\/h3>\n<p data-start=\"4271\" data-end=\"4436\">The BG40 uses <strong data-start=\"4298\" data-end=\"4327\">a<\/strong> built-in <strong data-start=\"4298\" data-end=\"4327\">3.7 V lithium-polymer battery<\/strong>. The sensor requires approximately <strong data-start=\"4365\" data-end=\"4395\">40 seconds to warm up<\/strong> before taking a measurement.<\/p>\n<h3 data-section-id=\"6l7dmw\" data-start=\"4438\" data-end=\"4459\">Technical Specifications<\/h3>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4461\" data-end=\"5131\">\n<thead data-start=\"4461\" data-end=\"4485\">\n<tr data-start=\"4461\" data-end=\"4485\">\n<th class=\"last:pe-10\" data-start=\"4461\" data-end=\"4470\" data-col-size=\"sm\">Feature<\/th>\n<th class=\"last:pe-10\" data-start=\"4470\" data-end=\"4485\" data-col-size=\"sm\">Trotec BG40<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4496\" data-end=\"5131\">\n<tr data-start=\"4496\" data-end=\"4549\">\n<td data-start=\"4496\" data-end=\"4510\" data-col-size=\"sm\">Device Type<\/td>\n<td data-start=\"4510\" data-end=\"4549\" data-col-size=\"sm\">Gas detector \/ gas leak detector<\/td>\n<\/tr>\n<tr data-start=\"4550\" data-end=\"4585\">\n<td data-start=\"4550\" data-end=\"4565\" data-col-size=\"sm\">Measurement Range<\/td>\n<td data-start=\"4565\" data-end=\"4585\" data-col-size=\"sm\"><strong data-start=\"4567\" data-end=\"4583\">0\u201310,000 ppm<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4586\" data-end=\"4628\">\n<td data-start=\"4586\" data-end=\"4599\" data-col-size=\"sm\">Sensitivity<\/td>\n<td data-start=\"4599\" data-end=\"4628\" data-col-size=\"sm\"><strong data-start=\"4601\" data-end=\"4626\">&lt;10 ppm for methane<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4629\" data-end=\"4656\">\n<td data-start=\"4629\" data-end=\"4642\" data-col-size=\"sm\">Repeatability<\/td>\n<td data-start=\"4642\" data-end=\"4656\" data-col-size=\"sm\"><strong data-start=\"4644\" data-end=\"4654\">50 ppm<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4657\" data-end=\"4687\">\n<td data-start=\"4657\" data-end=\"4674\" data-col-size=\"sm\">Response time<\/td>\n<td data-start=\"4674\" data-end=\"4687\" data-col-size=\"sm\"><strong data-start=\"4676\" data-end=\"4685\">about 2 s<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4688\" data-end=\"4725\">\n<td data-start=\"4688\" data-end=\"4711\" data-col-size=\"sm\">Standard Calibration<\/td>\n<td data-col-size=\"sm\" data-start=\"4711\" data-end=\"4725\"><strong data-start=\"4713\" data-end=\"4723\">methane<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4726\" data-end=\"4758\">\n<td data-start=\"4726\" data-end=\"4744\" data-col-size=\"sm\">Measurement ranges<\/td>\n<td data-start=\"4744\" data-end=\"4758\" data-col-size=\"sm\">x10 \/ x100<\/td>\n<\/tr>\n<tr data-start=\"4759\" data-end=\"4791\">\n<td data-start=\"4759\" data-end=\"4774\" data-col-size=\"sm\">x10 range<\/td>\n<td data-start=\"4774\" data-end=\"4791\" data-col-size=\"sm\">up to 1,000 ppm<\/td>\n<\/tr>\n<tr data-start=\"4792\" data-end=\"4827\">\n<td data-start=\"4792\" data-end=\"4808\" data-col-size=\"sm\">x100 range<\/td>\n<td data-start=\"4808\" data-end=\"4827\" data-col-size=\"sm\">up to 10,000 ppm<\/td>\n<\/tr>\n<tr data-start=\"4828\" data-end=\"4854\">\n<td data-start=\"4828\" data-end=\"4844\" data-col-size=\"sm\">Warm-up time<\/td>\n<td data-start=\"4844\" data-end=\"4854\" data-col-size=\"sm\">approx. 40 s<\/td>\n<\/tr>\n<tr data-start=\"4855\" data-end=\"4897\">\n<td data-start=\"4855\" data-end=\"4863\" data-col-size=\"sm\">Alarm<\/td>\n<td data-start=\"4863\" data-end=\"4897\" data-col-size=\"sm\">sound + visual + vibration<\/td>\n<\/tr>\n<tr data-start=\"4898\" data-end=\"4927\">\n<td data-start=\"4898\" data-end=\"4913\" data-col-size=\"sm\">Probe length<\/td>\n<td data-col-size=\"sm\" data-start=\"4913\" data-end=\"4927\"><strong data-start=\"4915\" data-end=\"4925\">400 mm<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4928\" data-end=\"4964\">\n<td data-start=\"4928\" data-end=\"4936\" data-col-size=\"sm\">Power Supply<\/td>\n<td data-start=\"4936\" data-end=\"4964\" data-col-size=\"sm\">3.7 V Li-ion polymer battery<\/td>\n<\/tr>\n<tr data-start=\"4965\" data-end=\"4998\">\n<td data-start=\"4965\" data-end=\"4982\" data-col-size=\"sm\">Operating temperature<\/td>\n<td data-start=\"4982\" data-end=\"4998\" data-col-size=\"sm\"><strong data-start=\"4984\" data-end=\"4996\">0\u2026+40 \u00b0C<\/strong><\/td>\n<\/tr>\n<tr data-start=\"4999\" data-end=\"5025\">\n<td data-start=\"4999\" data-end=\"5012\" data-col-size=\"sm\">Operating Humidity<\/td>\n<td data-start=\"5012\" data-end=\"5025\" data-col-size=\"sm\">10\u201385% RH<\/td>\n<\/tr>\n<tr data-start=\"5026\" data-end=\"5062\">\n<td data-start=\"5026\" data-end=\"5048\" data-col-size=\"sm\">Storage temperature<\/td>\n<td data-col-size=\"sm\" data-start=\"5048\" data-end=\"5062\">\u201310\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr data-start=\"5063\" data-end=\"5110\">\n<td data-start=\"5063\" data-end=\"5086\" data-col-size=\"sm\">Dimensions without probe<\/td>\n<td data-start=\"5086\" data-end=\"5110\" data-col-size=\"sm\"><strong data-start=\"5088\" data-end=\"5108\">45 \u00d7 60 \u00d7 220 mm<\/strong><\/td>\n<\/tr>\n<tr data-start=\"5111\" data-end=\"5131\">\n<td data-start=\"5111\" data-end=\"5118\" data-col-size=\"sm\">Weight<\/td>\n<td data-col-size=\"sm\" data-start=\"5118\" data-end=\"5131\"><strong data-start=\"5120\" data-end=\"5129\">410 g<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"5133\" data-end=\"5234\">The technical specifications are taken from the Troteci BG40 user manual.<\/p>\n<h3 data-section-id=\"jx27uq\" data-start=\"5236\" data-end=\"5291\">Important \u2013 The BG40 is not a substitute for a stationary gas alarm<\/h3>\n<p data-start=\"5293\" data-end=\"5352\">I would definitely highlight this distinction on Pro Air\u2019s product page.<\/p>\n<p data-start=\"5354\" data-end=\"5528\">The BG40 is <strong data-start=\"5362\" data-end=\"5433\">a portable measuring device for detecting and locating gas leaks<\/strong>. It should not be considered a substitute for a permanent gas or carbon monoxide alarm installed in a building.<\/p>\n<p data-start=\"5530\" data-end=\"5744\">Trotec also states that the device <strong data-start=\"5561\" data-end=\"5618\">must not be used in an explosive atmosphere or zone<\/strong>. High concentrations of flammable gas can pose a risk of fire, explosion, and suffocation.<\/p>\n<h3 data-section-id=\"m8hb02\" data-start=\"5746\" data-end=\"5778\">Is the BG40 a carbon monoxide detector?<\/h3>\n<p data-start=\"5780\" data-end=\"5962\">According to Trotec\u2019s documentation, the BG40 sensor may also respond <strong data-start=\"5841\" data-end=\"5870\">to carbon monoxide (CO)<\/strong>, but the device is calibrated for methane as standard.<\/p>\n<p data-start=\"5964\" data-end=\"6208\">Therefore, <strong data-start=\"5973\" data-end=\"6046\">I would not market the BG40 on the Pro Air page as a carbon monoxide detector or CO meter<\/strong>. To accurately measure carbon monoxide concentrations or for continuous safety monitoring, you must use a CO meter designed for that purpose or a certified carbon monoxide detector.<\/p>\n<p data-start=\"6210\" data-end=\"6264\">This is an important distinction from the perspective of SEO and customer safety.<\/p>\n<h3 data-section-id=\"11sxsqc\" data-start=\"6266\" data-end=\"6296\">Who is the Trotec BG40 suitable for?<\/h3>\n<p data-start=\"6298\" data-end=\"6468\">The BG40 is well-suited <strong data-start=\"6315\" data-end=\"6467\">for HVAC and maintenance technicians, gas equipment maintenance technicians, heating system installers, property management professionals, and technical staff at industrial facilities<\/strong>.<\/p>\n<p data-start=\"6470\" data-end=\"6585\">The device is particularly useful in situations where a gas leak is known or suspected, but its exact location needs to be pinpointed.<\/p>\n<h3 data-section-id=\"dfu780\" data-start=\"6587\" data-end=\"6607\">The kit includes<\/h3>\n<p data-start=\"6609\" data-end=\"6659\">According to Trotec\u2019s current manual, the kit includes:<\/p>\n<p data-start=\"6661\" data-end=\"6764\"><strong data-start=\"6661\" data-end=\"6690\">Trotec BG40 gas detector<\/strong>,<br data-start=\"6691\" data-end=\"6694\"\/><strong data-start=\"6694\" data-end=\"6705\">charger<\/strong>,<br data-start=\"6706\" data-end=\"6709\"\/><strong data-start=\"6709\" data-end=\"6723\">quick start guide<\/strong>.<\/p>\n<h3 data-section-id=\"1iljq6m\" data-start=\"6766\" data-end=\"6796\">Frequently Asked Questions<\/h3>\n<p data-start=\"6798\" data-end=\"6979\"><strong data-start=\"6798\" data-end=\"6826\">What does the Trotec BG40 measure?<\/strong><br data-start=\"6826\" data-end=\"6829\"\/>The BG40 is a gas leak detector with a measurement range of 0\u201310,000 ppm. The device is calibrated for methane as standard.<\/p>\n<p data-start=\"6981\" data-end=\"7138\"><strong data-start=\"6981\" data-end=\"7012\">Does the BG40 detect natural gas?<\/strong><br data-start=\"7012\" data-end=\"7015\"\/>Yes. Trotec explicitly lists natural gas and methane among the gases detectable by the BG40.<\/p>\n<p data-start=\"7140\" data-end=\"7249\"><strong data-start=\"7140\" data-end=\"7171\">Does the BG40 detect propane?<\/strong><br data-start=\"7171\" data-end=\"7174\"\/>Yes, the sensor also reacts to propane.<\/p>\n<p data-start=\"7251\" data-end=\"7391\"><strong data-start=\"7251\" data-end=\"7283\">Does the BG40 detect hydrogen?<\/strong><br data-start=\"7283\" data-end=\"7286\"\/>Yes. Hydrogen is included in the list of detectable gases specified by the manufacturer.<\/p>\n<p data-start=\"7393\" data-end=\"7592\"><strong data-start=\"7393\" data-end=\"7433\">Does the BG40 indicate the location of a gas leak?<\/strong><br data-start=\"7433\" data-end=\"7436\"\/>The device does not automatically determine the physical location. Using the 40-cm probe, concentration reading, and varying alarm frequency, the user can locate the source of the leak.<\/p>\n<p data-start=\"7594\" data-end=\"7747\"><strong data-start=\"7594\" data-end=\"7645\">Is the BG40 suitable for continuous gas monitoring at home?<\/strong><br data-start=\"7645\" data-end=\"7648\"\/>No. The BG40 is a portable measurement and leak detection device, not a stationary 24\/7 gas alarm.<\/p>\n<p data-start=\"7749\" data-end=\"7943\"><strong data-start=\"7749\" data-end=\"7806\">Can the BG40 be used in an ATEX-certified explosive atmosphere?<\/strong><br data-start=\"7806\" data-end=\"7809\"\/>No. The Trotec user manual prohibits the use of the device in explosive atmospheres and areas.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3><strong>Trotec BG40 Gas Detector<\/strong><\/h3>\n<p><strong><em>Highly sensitive detection of even the smallest gas leaks<\/em><\/strong><\/p>\n<p data-start=\"74\" data-end=\"438\"><strong data-start=\"74\" data-end=\"89\">The Trotec BG40<\/strong> is <strong data-start=\"109\" data-end=\"150\">a professional gas detector\u2014or gas leak detector<\/strong>\u2014designed for the rapid localization of leaks of flammable and other sensitive gases. The device responds to changes in gas concentration <strong data-start=\"301\" data-end=\"316\">in as little as approximately 2 seconds<\/strong>; its measurement range is <strong data-start=\"334\" data-end=\"350\">0\u201310,000 ppm<\/strong>, and its sensitivity for methane is less than <strong data-start=\"389\" data-end=\"399\">10 ppm<\/strong>.<\/p>\n<p data-start=\"440\" data-end=\"655\">The BG40 combines the functions of a gas detector and an alarm device in a single unit. When gas is detected, the device alerts the user with <strong data-start=\"554\" data-end=\"599\">an audible, visual, and vibrating alarm<\/strong>, the intensity of which increases as the gas concentration rises.<\/p>\n<p data-start=\"657\" data-end=\"868\">The 40-cm-long semi-flexible probe allows you to inspect even hard-to-reach areas, such as pipe connections, areas behind gas appliances, and connection points for utility systems.<\/p>\n","protected":false},"featured_media":44647,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"Trotec BG40 Gas Detector and Gas Leak Detector | Pro Air O\u00dc","_seopress_titles_desc":"Trotec BG40 gas detector for detecting gas leaks. Measurement range: 0\u201310,000 ppm; sensitivity: &lt;10 ppm; response time: 2 s; and a 40 cm flexible probe.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"gas detector,Trotec BG40,BG40 gas detector,gas leak detector,gas leak meter,gas leak locator,gas leak detection,gas sensor,portable gas detector,natural gas detector,methane detector,propane detector,combustible gas detector,gas leak tester,professional gas detector,gas line leak check,gas leak detection device"},"product_brand":[],"product_cat":[977,975],"product_tag":[],"class_list":["post-44645","product","type-product","status-publish","has-post-thumbnail","product_cat-heide","product_cat-measuring-instruments","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/44645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/44647"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=44645"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=44645"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=44645"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=44645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}