{"id":42714,"date":"2026-06-17T10:04:31","date_gmt":"2026-06-17T10:04:31","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-pqc-23eu-air-quality-monitor-includes-calibration-certificate\/"},"modified":"2026-06-17T10:04:31","modified_gmt":"2026-06-17T10:04:31","slug":"pce-pqc-23eu-air-quality-monitor-includes-calibration-certificate","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-pqc-23eu-air-quality-monitor-includes-calibration-certificate\/","title":{"rendered":"PCE-PQC 23EU Air Quality Monitor Includes: Calibration Certificate"},"content":{"rendered":"<h2 class=\"main-title main-heading\">PCE-PQC 23EU Air Quality Monitor Includes: Calibration Certificate <\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div><strong>PCE-PQC 2xEU Series Air Quality Monitor, including calibration certificate <\/strong><\/div>\n<div><strong>Includes CO2 sensor \/ Wide measurement range \/ PID sensor \/ 6 measurement channels \/ Factory-calibrated  <\/strong><\/div>\n<div>The PCE-PQC 2xEU series air quality monitor measures particle sizes ranging from 0.3 \u03bcm to 25 \u03bcm by mass concentration and also records parameters such as temperature, relative humidity, CO2, and TVOC (PCE-PQC 23EU only). This meter is the most versatile air quality monitor available, featuring advanced power management and the industry\u2019s first sleep mode, which allows the battery to operate for periods that can exceed one month on a single charge. The PCE-PQC 2xEU series can be used as a standalone, battery-powered instrument or easily integrated into building automation and plant monitoring systems via Ethernet or USB.  <\/div>\n<div><\/div>\n<div>The PCE-PQC 2xEU series air quality monitor can measure not only particle size and mass concentration, but also the carbon dioxide content in the air. It also measures air temperature and relative humidity. The PCE-PQC 23EU air quality monitor also features a photoionization detector (PID), which can be used to measure volatile organic compounds (VOCs).  <\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata2\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\">Highlights<\/h1>\n<div class=\"usertext\">&#8211; CO2 sensor<br \/>\n&#8211; PID sensor<br \/>\n&#8211; Temperature and humidity measurement<br \/>\n&#8211; Ethernet<br \/>\n&#8211; USB<br \/>\n&#8211; Wi-Fi (optional)<br \/>\n&#8211; <strong>Includes. Calibration certificate compliant with NIST ISO 21501-4 and JIS B9921<\/strong><\/div>\n<\/div>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\">Specifications<\/h1>\n<div class=\"usertext\">\n<table border=\"0\" cellspacing=\"0\" bgcolor=\"#FFFFFF\">\n<tbody>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">0.3 &#8230; 25 \u03bcm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measuring Channel Dimensions<\/td>\n<td valign=\"top\">Factory-calibrated to 0.3, 0.5, 1.0, 3.0, 5.0, and 10.0 \u03bcm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Counting Efficiency<\/td>\n<td valign=\"top\">50% at 0.3 \u03bcm and 100% at &gt; 0.45 \u03bcm, according to JIS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Displaying Particle Mass<\/td>\n<td valign=\"top\">PM0.5, PM1.0, PM2.5, PM5.0, PM10, and TPM<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flow<\/td>\n<td valign=\"top\">2.83 L\/min (0.1 ft <sup>\u00b3<\/sup> \/min)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Random loss<\/td>\n<td valign=\"top\">5% at 4,000,000 particles\/ft\u00b3<\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td valign=\"top\">Battery<\/td>\n<td valign=\"top\">10 h<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Light Source<\/td>\n<td valign=\"top\">Long-life laser diode<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Zero count<\/td>\n<td valign=\"top\">&lt;1 count \/ 5 min (&lt;2 particles \/ foot\u00b3) in accordance with ISO 21501-4 and JIS<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Counting Modes<\/td>\n<td valign=\"top\">Automatic, manual, real-time, cumulative \/<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">differential, mass concentration<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Alarms<\/td>\n<td valign=\"top\">Counts from 1 to 9,999,999, adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Calibration<\/td>\n<td valign=\"top\">Traceable to NIST<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Screen<\/td>\n<td valign=\"top\">4.3&#8243; WQVGA color touchscreen, 480&#215;272 px<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Printer<\/td>\n<td valign=\"top\">External thermal printer<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Striving<\/td>\n<td valign=\"top\">Internal pump with automatic control<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">current control<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Air Outlet<\/td>\n<td valign=\"top\">Internal HEPA filter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Battery Pack<\/td>\n<td valign=\"top\">Replaceable Li-Ion battery<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Charging time<\/td>\n<td valign=\"top\">About 4 hours<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Reports<\/td>\n<td valign=\"top\">ISO 14644-1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">EU GMP Annex 1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">FS 209E<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Setup<\/td>\n<td valign=\"top\">Memory for 50 custom configurations<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Standards<\/td>\n<td valign=\"top\">ISO 21501-4 and JIS B9921<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Dimensions<\/td>\n<td valign=\"top\">13.3 x 10.5 x 21 cm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td valign=\"top\">1.8 kg<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Archiving<\/td>\n<td valign=\"top\">45,000 data sets (sound memory), consisting of<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Particle counting, temperature and humidity, CO2 (PID), <\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Sample Locations<\/td>\n<td valign=\"top\">You can save up to 1,000 locations and times<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Test duration<\/td>\n<td valign=\"top\">1 s &#8230; 99 h, adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power Supply<\/td>\n<td valign=\"top\">110 &#8230; 240 V AC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating Conditions<\/td>\n<td valign=\"top\">5 &#8230; 40 \u00b0C \/ 41 &#8230; 104 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Up to 95% relative humidity does not condense<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage Conditions<\/td>\n<td valign=\"top\">0 &#8230; 50 \u00b0C \/ 32 &#8230; 122 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Up to 98% relative humidity does not condense<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO2 sensor<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">0&#8230;5000 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">1 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">\u00b1 1% of the measurement range<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">PID sensor<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">0&#8230;50 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">0.001 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">\u00b1 1.5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Minimum concentration<\/td>\n<td valign=\"top\">5 ppb<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Response time<\/td>\n<td valign=\"top\">< 3 sec.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Internal Temperature\/Humidity Sensor<\/td>\n<td valign=\"top\">0 &#8230; 50 \u00b0C (32 &#8230; 122 \u00b0F), 15 &#8230; 90% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">0.5 \u00b0C \/ \u00b1 0.9 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">\u00b1 0.5 \u00b0C \/ \u00b1 0.9 \u00b0F, \u00b1 2% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Interface<\/td>\n<td valign=\"top\">Ethernet, USB<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Optional Interfaces<\/td>\n<td valign=\"top\">Wi-Fi 802.11 b\/g, RS485, or RS232<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of measurement channels<\/td>\n<td valign=\"top\">6<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"tab-customdata4\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\">Scope of Delivery<\/h1>\n<div class=\"usertext\">1 x Air Quality Monitor PCE-PQC 23EU<br \/>\n1 x Isokinetic Probe<br \/>\n1 x Temperature and Humidity Sensor<br \/>\n1 x Cleaning Filter<br \/>\n1 x Li-ion rechargeable battery<br \/>\n1 x Software for downloading data<br \/>\n1 x USB cable<br \/>\n1 x Power supply \/ battery charger<br \/>\n1 x User manual<br \/>\n<strong>1 x NIST-compliant calibration certificate<\/strong><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"main-title main-heading\">PCE-PQC 23EU Air Quality Monitor Includes: Calibration Certificate <\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div><strong>PCE-PQC 2xEU Series Air Quality Monitor, including calibration certificate <\/strong><\/div>\n<div><strong>Includes CO2 sensor \/ Wide measurement range \/ PID sensor \/ 6 measurement channels \/ Factory-calibrated  <\/strong><\/div>\n<div>The PCE-PQC 2xEU series air quality monitor measures particle sizes ranging from 0.3 \u03bcm to 25 \u03bcm by mass concentration and also records parameters such as temperature, relative humidity, CO2, and TVOC (PCE-PQC 23EU only). This meter is the most versatile air quality monitor available, featuring advanced power management and the industry\u2019s first sleep mode, which allows the battery to operate for periods that can exceed one month on a single charge. The PCE-PQC 2xEU series can be used as a standalone, battery-powered instrument or easily integrated into building automation and plant monitoring systems via Ethernet or USB.  <\/div>\n<div><\/div>\n<div>The PCE-PQC 2xEU series air quality monitor can measure not only particle size and mass concentration, but also the carbon dioxide content in the air. It also measures air temperature and relative humidity. The PCE-PQC 23EU air quality monitor also features a photoionization detector (PID), which can be used to measure volatile organic compounds (VOCs).  <\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":42716,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"PCE-PQC 23EU Air Quality Monitor","_seopress_titles_desc":"PCE-PQC 2xEU Series Air Quality Monitor, including calibration certificate. Includes CO2 sensor, wide measurement range, PID sensor, 6 measurement channels, factory-calibrated","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[],"product_cat":[977,975],"product_tag":[],"class_list":["post-42714","product","type-product","status-publish","has-post-thumbnail","product_cat-heide","product_cat-measuring-instruments","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42716"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42714"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42714"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42714"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}