{"id":42437,"date":"2026-06-17T10:04:32","date_gmt":"2026-06-17T10:04:32","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-wmm-100-carbon-dioxide-and-oxygen-meter\/"},"modified":"2026-06-17T10:04:32","modified_gmt":"2026-06-17T10:04:32","slug":"pce-wmm-100-carbon-dioxide-and-oxygen-meter","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-wmm-100-carbon-dioxide-and-oxygen-meter\/","title":{"rendered":"PCE-WMM 100 Carbon Dioxide and Oxygen Meter"},"content":{"rendered":"<h2 class=\"main-title main-heading\">PCE-WMM 100 Carbon Dioxide and Oxygen Meter<\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div><strong>Air Quality Carbon Dioxide Monitor <\/strong><strong>PCE-WMM 100<\/strong><\/div>\n<div>CO2 alarm system for carbon dioxide and oxygen \/ Adjustable alarms \/ 4-digit LCD display \/ Consists of a main unit and a remote unit \/ Relay contacts \/ Analog output<\/div>\n<div><\/div>\n<div>The PCE-WMM 100 CO2 alarm system consists of a main unit and a remote display. The PCE-WMM 100 CO2 gas detector is used to measure carbon dioxide and oxygen levels at a specific location. The CO2 alarm system protects people from odorless CO2 gas and also warns of low oxygen levels in the air. The gas alarm system displays the measured values on an LCD screen. The PCE-WMM 100 CO\u2082 alarm has two relays that can be used to control warning lights or audible alarms. In addition, the CO\u2082 alarm has a built-in audible alarm that emits an 80 dB sound signal in the event of an alarm.     <\/div>\n<div><\/div>\n<div>The warning device is used wherever CO2 may be released. This includes warehouses, breweries, wine cellars, or restaurants. The main unit is IP54-rated. Four LEDs on the front panel provide information about the system\u2019s status.   <\/div>\n<div>\n\n<\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata2\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\">Benefits &#8211; PCE-WMM 100 Carbon Dioxide and Oxygen Meter<\/h3>\n<div class=\"usertext\">\n<div>&#8211; CO2 and O2 sensor<\/div>\n<div>&#8211; <span lang=\"en\">Main and remote control<\/span><\/div>\n<div>&#8211; Alarm relay<\/div>\n<div>&#8211; 4 &#8230; 20 mA analog output<\/div>\n<div>&#8211; Audible alarm<\/div>\n<div>&#8211; Integrated temperature measurement<\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\">Specifications<\/h3>\n<div class=\"usertext\">\n<table>\n<tbody>\n<tr>\n<td valign=\"top\">Measurement Function<\/td>\n<td valign=\"top\"><strong>CO2<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">0 &#8230;. 50,000 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">&lt;10,000 ppm: 10 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">&gt;10,001 ppm: 100 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">\u00b1 100 ppm \/ 5% of the measured value<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement Function<\/td>\n<td valign=\"top\"><strong>O2<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">O2: 0 &#8230; 30%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">0.1%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">&lt; 3% of the measured value<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement Function<\/td>\n<td valign=\"top\"><strong>Temperature<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Measurement range<\/td>\n<td valign=\"top\">0 &#8230; 50 \u00b0C \/ 32 &#8230; 122 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Resolution<\/td>\n<td valign=\"top\">0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Accuracy<\/td>\n<td valign=\"top\">\u00b1 1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Repeatability<\/td>\n<td valign=\"top\">CO2: \u00b120 ppm at 400 ppm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">O2: &lt; \u00b11 %<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Temperature Dependence<\/td>\n<td valign=\"top\">\u00b1 0.3% of the measured value per \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">(at 25 \u00b0C)<\/td>\n<td valign=\"top\">\u00b1 2 ppm\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">(whichever is greater)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure Dependence<\/td>\n<td valign=\"top\">0.13% of the measured value per mmHg<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Response Time<\/td>\n<td valign=\"top\">CO2: T90 &lt; 60 s<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">O2: T90 &lt; 30s<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Temperature: 20 &#8230; 30 m<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Alarm 1<\/td>\n<td valign=\"top\">CO2: 5,000 ppm, 1%, 1.5%, 2%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">O2: 18%, 18.5%, 19%, 19.5%, 20%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Alarm 2<\/td>\n<td valign=\"top\">CO2: 1.5%, 2%, 2.5%, 3%, 3.5%, 4%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">O2: 16%, 16.5%, 17%, 17.5%, 18%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Alarm Volume<\/td>\n<td valign=\"top\">80 dB \/ 0.1 m<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Heating time<\/td>\n<td valign=\"top\">&lt; 60 seconds at an ambient temperature of 22 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power Supply<\/td>\n<td valign=\"top\">Power adapter 100 &#8230; 240 V AC \/ 6 V DC \/ 0.5 A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Analog Output<\/td>\n<td valign=\"top\">2 x 4 &#8230; 20 mA<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Load<\/td>\n<td valign=\"top\">&lt;150 ohms<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relay<\/td>\n<td valign=\"top\">max. 2 A \/ 30 V DC \/ 250 V AC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating Conditions<\/td>\n<td valign=\"top\">0 &#8230; 40 \u00b0C \/ 32 &#8230; 104 \u00b0F \/ max 95% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage Conditions<\/td>\n<td valign=\"top\">-20 &#8230; 60 \u00b0C \/ -4 &#8230; 140 \u00b0F \/ max. 95% relative humidity<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Protection Rating<\/td>\n<td valign=\"top\">Rating: IP54<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Remote control: &#8211;<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Dimensions<\/td>\n<td valign=\"top\">Main unit: 170 x 63 x 26 mm \/ 6.6 x 2.4 x 1.0 inches<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Remote control: 80 x 35.7 x 10 mm \/ 3.1 x 1.4 x 0.3 inches<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td valign=\"top\">Unit weight: 1200 g with cable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Remote control: 120 g \/ 4.2 ounces<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"tab-customdata4\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\">Package Contents<\/h3>\n<div class=\"usertext\">1 x PCE-WMM 100 carbon dioxide air quality meter<br \/>\n1 x remote control<br \/>\n1 x 8 m connection cable<br \/>\n1 x power adapter<br \/>\n1 x installation kit<br \/>\n1 x user manual<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2>PCE-WMM 100 Carbon Dioxide and Oxygen Meter<\/h2>\n<p>The PCE-WMM 100 CO2 alarm system consists of a main unit and a remote display. The PCE-WMM 100 CO2 gas detector is used to measure carbon dioxide and oxygen levels at a specific location. The CO2 alarm system protects people from odorless CO2 gas and also warns of low oxygen levels in the air. The gas alarm system displays the measured values on an LCD screen. The PCE-WMM 100 CO\u2082 alarm has two relays that can be used to control strobe lights or audible alarms. In addition, the CO\u2082 alarm has a built-in audible alarm that emits an 80 dB sound signal in the event of an alarm.     <\/p>\n","protected":false},"featured_media":42440,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"PCE-WMM 100 Carbon Dioxide and Oxygen Meter","_seopress_titles_desc":"The PCE-WMM 100 carbon dioxide and oxygen meter consists of a main unit and a remote display. The detector is used to measure carbon dioxide and oxygen at a specific location","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[],"product_cat":[977,975],"product_tag":[],"class_list":["post-42437","product","type-product","status-publish","has-post-thumbnail","product_cat-heide","product_cat-measuring-instruments","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42440"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42437"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42437"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42437"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}