{"id":42396,"date":"2026-06-17T10:05:15","date_gmt":"2026-06-17T10:05:15","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-pa-5500-three-phase-electricity-meter\/"},"modified":"2026-06-17T10:05:15","modified_gmt":"2026-06-17T10:05:15","slug":"pce-pa-5500-three-phase-electricity-meter","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-pa-5500-three-phase-electricity-meter\/","title":{"rendered":"PCE-PA 5500 Three-Phase Electricity Meter"},"content":{"rendered":"<h2 class=\"main-title main-heading\"><span>PCE-PA 5500 Three-Phase Electricity Meter<\/span><\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div class=\"row\">\n<div class=\"col-md-12 text-center\"><strong><span>3-phase energy meter with RS485 interface \/ easy-to-use buttons \/ Class 0.5 for key performance parameters \/ high-resolution black-and-white LCD display<\/span><\/strong><\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-md-12 text-justify\">\n<p><span>A 3-phase energy meter is a compact device for measuring and displaying various grid parameters in three-phase networks. This 3-phase energy meter can record energy values for individual consumers or electrical circuits. In addition to voltages and currents, it measures apparent, reactive, and active power, as well as active and reactive energy, and displays these values on a 68 x 55 mm screen. Furthermore, this three-phase energy meter features an integrated RS485 interface, which allows for integration into existing systems. Communication via the RS485 interface uses the Modbus RTU protocol. This allows you to read measured values from the three-phase energy meter or to read and modify the device\u2019s settings.     <\/span><\/p>\n<p><span>The 3-phase electricity meter is designed for installation in an electrical panel with a 96&#215;96 mm cutout. The package includes a transparent door that can be attached to the front panel, thereby protecting the device from dust and moisture. In addition to numerous measurement functions, the 3-phase energy meter offers alarm functions. A stable power supply is a top priority for every utility operator. To prevent power quality fluctuations and disruptions, grid monitoring, control, and automation must be adapted and optimized.    <\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata2\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\"><span>features<\/span><\/h3>\n<div class=\"usertext\">\n<div><span>&#8211; AC voltage: 30 &#8230; 264 V<\/span><\/div>\n<div><span>&#8211; Direct current, alternating current: 0.025 mA &#8230; 5 A<\/span><\/div>\n<div><span>&#8211; energy meter<\/span><\/div>\n<div><span>&#8211; RS485 Modbus interface<\/span><\/div>\n<div><span>&#8211; Accuracy class: 0.5<\/span><\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\"><span>specification<\/span><\/h3>\n<div class=\"usertext\">\n<table border=\"0\" cellspacing=\"0\" bgcolor=\"#fff\">\n<tbody>\n<tr>\n<td valign=\"top\"><strong><span>alternating current (AC)<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement range <\/span><\/td>\n<td valign=\"top\"><span>30 V &#8230; 264 V<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution <\/span><\/td>\n<td valign=\"top\"><span>0.1 V<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy <\/span><\/td>\n<td valign=\"top\"><span>0.5%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>overload <\/span><\/td>\n<td valign=\"top\"><span>1500 VAC continuous<\/span><br \/>\n<span>2500 VAC, 50\u201360 Hz for one minute<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>alternating current (AC)<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement range <\/span><\/td>\n<td valign=\"top\"><span>0.025 A &#8230; 5 A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution <\/span><\/td>\n<td valign=\"top\"><span>0.01 A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy <\/span><\/td>\n<td valign=\"top\"><span>0.5%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>overload <\/span><\/td>\n<td valign=\"top\"><span>10x RMS over a 1-second period.<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>active force<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement range <\/span><\/td>\n<td valign=\"top\"><span>0.75 W &#8230; 1320 W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution <\/span><\/td>\n<td valign=\"top\"><span>0.01 W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy <\/span><\/td>\n<td valign=\"top\"><span>0.5%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>power factor<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>measurement range <\/span><\/td>\n<td valign=\"top\"><span>-1 &#8230; +1<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution <\/span><\/td>\n<td valign=\"top\"><span>0.001<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy <\/span><\/td>\n<td valign=\"top\"><span>0.5%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>frequency<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement range <\/span><\/td>\n<td valign=\"top\"><span>45 Hz &#8230; 65 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution <\/span><\/td>\n<td valign=\"top\"><span>0.01 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy <\/span><\/td>\n<td valign=\"top\"><span>0.5%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>harmonic measurement<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>measurement range <\/span><\/td>\n<td valign=\"top\"><span>1 (atomic number) &#8230; 50 (atomic number)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>current range <\/span><\/td>\n<td valign=\"top\"><span>20 &#8230; 100%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>voltage range <\/span><\/td>\n<td valign=\"top\"><span>0.1 &#8230; 100%<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>General Technical Specifications<\/span><\/strong><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Display Type <\/span><\/td>\n<td valign=\"top\"><span>LCD with backlight<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>screen size <\/span><\/td>\n<td valign=\"top\"><span>3.4 inches<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>interface <\/span><\/td>\n<td valign=\"top\"><span>RS485<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>standard(s) <\/span><\/td>\n<td valign=\"top\"><span>IEC 62053-22, GB\/T 18215.322-2008, IEC 61010-1<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>phase shift <\/span><\/td>\n<td valign=\"top\"><span>0 &#8230; 359.9\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>panel cutout <\/span><\/td>\n<td valign=\"top\"><span>96&#215;96 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Menu Language <\/span><\/td>\n<td valign=\"top\"><span>English<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Protection class (device) <\/span><\/td>\n<td valign=\"top\"><span>IP20<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>power supply <\/span><\/td>\n<td valign=\"top\"><span>100 &#8230; 260 VAC, approx. 5 W<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Weight <\/span><\/td>\n<td valign=\"top\"><span>474 g<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>depth <\/span><\/td>\n<td valign=\"top\"><span>110 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Operating conditions <\/span><\/td>\n<td valign=\"top\"><span>-20&#8230;60 \u00b0C, 0&#8230;95% relative humidity<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Storage conditions <\/span><\/td>\n<td valign=\"top\"><span>-20&#8230;65 \u00b0C, 30&#8230;80% relative humidity<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>battery <\/span><\/td>\n<td valign=\"top\"><span>1x 3 V CR1225, lithium<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>capacity <\/span><\/td>\n<td valign=\"top\"><span>50 mAh<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"tab-customdata4\" class=\"tab-pane clear fade in \">\n<h3 class=\"headline\"><span>scope of delivery<\/span><\/h3>\n<div class=\"usertext\">\n<div><span>1 x PCE-PA 5500 3-phase electricity meter<\/span><\/div>\n<div><span>1 x transparent exterior door<\/span><\/div>\n<div><span>1 x slotted screwdriver<\/span><\/div>\n<div><span>1 x user manual<\/span><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3 class=\"main-title main-heading\">PCE-PA 5500 Three-Phase Electricity Meter<\/h3>\n<p><strong>3-phase energy meter with RS485 interface \/ easy-to-use buttons \/ Class 0.5 for key performance parameters \/ high-resolution black-and-white LCD display<\/strong><\/p>\n","protected":false},"featured_media":42398,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"PCE-PA 5500 Three-Phase Electricity Meter","_seopress_titles_desc":"PCE-PA 5500 Three-Phase Electricity Meter","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1004,975],"product_tag":[],"class_list":["post-42396","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-energy-consumption-meter","product_cat-measuring-instruments","first","onbackorder","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42396","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42398"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42396"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42396"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42396"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42396"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}